These items are designed for use in closed hydronic systems. Do not use in plumbing applications. These
items do not meet the low-lead plumbing standards of U.S. and Canada.
Product range
Code 559920A 2+0 separator-manifold with built-in mounting brackets and pre-formed
insulation. Size: 1" NPT female main; 1" NPT male branches.
Code 559921A 2+1 separator-manifold with built-in mounting brackets and pre-formed
insulation. Size: 1" NPT female main; 1" NPT male branches.
Code 559922A 2+2 separator-manifold with angle mounting brackets and pre-formed insulation.
Size: 1 1/4" NPT female main; 1" NPT male branches.
Code 559931A 3+1 separator-manifold with angle mounting brackets and pre-formed insulation.
Size: 1 1/4" NPT female main; 1" NPT male branches.
Technical characteristics
Materials:
Body:
Maximum working pressure:
Working temperature range:
Performance:
Medium:
Maximum glycol percentage:
Connections:
Center distances:
Insulation
Material:
Thickness:
Density:
Thermal conductivity:
Temperature range:
Reaction to fire (UL 94):
Function
The Hydrolink™, combining a hydraulic separator with a
distribution manifold, is used in heating and air-conditioning
systems. It provides a chamber to hydraulically separate the
boiler (or chiller) circuit from the distribution circuits and also
provides a self-contained manifold station that supplies up
to four independently controlled load circuits with the same
supply temperature. Available configurations are compact,
and can be easily installed in any hydronic system, saving
space.
Water and non-hazardous glycol solutions
- main:
3+1 and 2+2:
2+0 and 2+1:
- branches:
3+1 and 2+2:
2+0 and 2+1:
- air vent valve:
- drain valve:
- main:
3+1 and 2+2:
2+0 and 2+1:
- branches:
3+1 and 2+2:
2+0 and 2+1:
0.25 BTU/in (.037 W/mK) at 50°F (10°C)
1
www.caleffi.com
painted steel
100 psi (7 bar)
32 to 230°F (0 to 110°C)
1 1/4" NPT female
1" NPT female
1" NPT male
1" NPT male
1/2" NPT female
1/2" NPT female
3 1/8" (80 mm)
2 3/8" (60 mm)
3/4" (20 mm)
3 lb/ft
20 to 250°F (-5–120°C)
38483.03
50%
5" (125 mm)
5" (125 mm)
EPP
(45 kg/m
)
3
3
class HBF

Advertisement

loading

Summary of Contents for CALEFFI HydroLink 559921A

  • Page 1 38483.03 www.caleffi.com HydroLink™ © Copyright 2018 Caleffi Function The Hydrolink™, combining a hydraulic separator with a distribution manifold, is used in heating and air-conditioning systems. It provides a chamber to hydraulically separate the boiler (or chiller) circuit from the distribution circuits and also...
  • Page 2 Flow Characteristics Maximum recommended flow rates at connections: Secondary Branches Primary (totals) 9 gpm (.56 l/s) 22 gpm (1.4 l/s) 9 gpm (.56 l/s) 22 gpm (1.4 l/s) 11 gpm (.70 l/s) 26 gpm (1.67 l/s) 11 gpm (.70 l/s) 26 gpm (1.67 l/s) SAFETY INSTRUCTION This safety alert symbol will be used in this manual to draw attention to safety related instructions.
  • Page 3 2. If the HydroLink™ unit is to be used with chilled water, spread a thin layer of sealant around the outer edges of the pre-formed insulation, wait until the solvent has evaporated (about 10 minutes) and then assemble. CALEFFI CALEFFI 2,25 2,25 1,75 1,75...
  • Page 4 2 of the previous section. Service Instructions There is no service required for the HydroLink™ device. Leave this manual for the user. 7-23-18 Scan to view · Caleffi North America, Inc. 3883 West Milwaukee Road Milwaukee, WI 53208 Installation Tip T: 414.238.2360 F: 414.238.2366...

This manual is also suitable for:

Hydrolink 559922aHydrolink 559931aHydrolink 559920a