Pressure filter

Advertisement

Available languages

Available languages

Turn the UV-C pipe cap (39) counter-clockwise and remove it from the
UV-C pipe.
Remove the screw and plate from the pivot rod (18).
Remove the black cap (37).
Remove the filter foam rings (35) from the UV-C tube.
Clean the filter foam of the filter foam rings (35) with clean tap or pond
water.
If the foam of the foam rings (35) cannot be cleaned, or have come out
of shape, they must be replaced.
Replace the foam rings (35) on the UV-C tube in an alternate pattern
(yellow, blue, yellow, and so on). terug om de UV-c buis.
Place the black cap (37) back on the UV-C pipe, make sure the pivot rod
(18) and the pivot rod holder (36) are properly mounted and mount the
plate and screw.
Place the UV-C pipe cap (38+39) back on the UV-C pipe and fix it by
turning the UV-C pipe cap (39) in a clockwise direction.
Only on VarioPress 14000: Take the basket with bio balls (40) from the
tank (43) and rinse it with clean pipe or pond water.
Also clean the tank (43) and o-ring (41) with clean pipe or pond water.
Place the basket with bio-balls (40) back into the tank (43).
Place the o-ring (41) back on the tank, by placing it on top of the first
corner (see illustration 6).
Place the lid with the foam package back on the tank (43), upright.
Return the clamp ring (42+44) and clamp it closed.
Reconnect all pipes to the pressure filter (remember the seal (27)):
Attach the supply hose / pipe to connection (A).
Attach the return hose / pipe to connection (F).
Attach the waste water hose / pipe to connection (G).
Put the pump into operation by plugging it into the power outlet. Follow
the pump instructions carefully.
If no leaking is found, you can also put the UV-C lamp of the pressure
filter into operation by plugging it into the power outlet.
Cleaning quartz glass and replacing UV-C lamp and quartz glass:
(illustration 7, 11 and 12, page 4, 6 and 7):
The UV-C lamp (9) has a life expectancy of about 7000 hours. If the lamp is used
24 hours a day, we recommend replacing it every season.
If the water turns green, clean the quartz glass first. If the UV-C lamp (9) has
done 7000 service hours or when the water starts turning green again, the UV-C
lamp (9) needs to be replaced.
Observe the safety instructions.
1.
Unplug the UV-C and pump from the power outlet to turn them off.
WARNING! UV-C light is harmful to skin and eyes, always switch off the
UV-C lamp before replacing it.
2.
Remove the 4 screws from the UV-C cap (2+7).
3.
Lift the UV-C cap (2+7) straight up from the lid (13).
4.
Clean and dry the quartz glass (11) using clean pipe or pond water and a
soft, clean cloth, do not scratch.
If the UV-C lamp (9) or quartz glass (11) don't need to be replaced,
continue with point 12.
5.
Loosen the quartz glass coupling nut (12).
6.
Carefully remove the quartz glass (11) from the UV-C cap (7).