1. Precaution 1. Read this manual carefully before installing or using the device. 2. Before first use, check / unscrew connections of the fluorescent tubes. If the screw connection is too strong, the arc tube will break due to temperature induced expansion. 3.
2. Technical specifications Model ECO IRE1 Input voltage 230V 50/60Hz Single phase Total power 1100W Curing area 800x500mm Temperature 40°C - 75°C adjustable Timer 0 Min – 60 Min adjustable Light intensity 100% 1. Power switch 2. Control 3. Cassette 4.
3. Installation 1. Installation of the substructure: a. Remove the substructure from the packaging. b. Place the substructure on the ground. c. Attach the four wheels to the base and tighten the screws. d. Make sure the rollers with brakes are mounted on the back of the substructure. 2.
4. Operation 1. Connect the electricity. The supply cable must be at least 4mm² at 230V. Make sure the supply voltage and frequency are as specified correspond to the type plate of the device. 2. Set the distance between the device and the workpiece. Usually a distance of 30 – 60 cm is to be kept.
5. Trouble shooting Error Reason Solution 1. Check the light tube / if 1. Light tube defective necessary exchange* Light tube doesn‘ work 2. Not connected 2. Check connectionss 1. Check main switch, 1. Malfunction main replace if necessary* Device can not be switch switched on/off 2.
6. Light tubes exchange 1. Remove cassette for tube replacement 2. Remove protective grille 3. Remove both holder plates from the sides of the cassette 4. Remove the fixed plates from both ends of the cassette 5. Disconnect cable connections and screws. Subsequently the arc tube can be exchanged 6.