Bair Hugger 505 Operator's Manual

Bair Hugger 505 Operator's Manual

Temperature management unit
Hide thumbs Also See for 505:

Advertisement

Check the Bair Hugger therapy website to ensure you have the most recent version of this document.
Betriebshandbuch für Bair Hugger*
Temperaturmanagement-Geräte
Modell 505
Manuel de l'utilisateur pour les
appareils de gestion de la température
Bair Hugger* Modèle 505
Manuale d'uso delle unità di gestione
della temperatura Bair Hugger*
Modello 505
Manual del usuario para las
unidades de control de temperatura
Bair Hugger*, Modelo 505
Manual do utilizador das unidades de
gestão de temperatura Bair Hugger*
Modelo 505
Bair Hugger* Temperatuurregelunit
Model 505 Gebruikshandleiding
Brugsanvisning til Bair Hugger*
temperaturreguleringsenheder,
Model 505
To t a l Te m p e r a t u r e M a n a g e m e n t S y s t e m
Bair Hugger*
Temperature Management Unit
Model 505
Operator's Manual
Bruksanvisning till Bair Hugger*
Modell 505 temperaturstyrenhet
Brukerhåndbok for Bair Hugger*-
temperatur-behandlingsenhet,
Modell 505
Bair Hugger* -lämpötilansäätölaitteen
Malli 505 käyttäjän opas
Εγχειρίδιο Χρήσης Bair Hugger*
Μονάδα διαχείρισης θερμοκρασίας,
Μοντέλο 505
取扱説明書 ベアーハガーモ
デル505体温管理装置
Instrukcja Obsługi Dmuchawy
Bair Hugger* Model 505 - urządzenia
do aktywnego przeciwdziałania
hipotermii
Bair Hugger* 505 sz. Modell
hőmérséklet-szabályozó egység
használati utasítása
www.bairhugger.com
Návod k obsluze jednotky regulace
teploty Bair Hugger* typ 505
Operatoriaus Vadovas „Bair Hugger"*
Modelis 505 Temperatūros reguliavimo
prietaisas
Руководство по эксплуатации
Bair Hugger* Mодель 505 Устройство
управления температурой
操作员手册 505型
Bair Hugger* 温度管理仪
reorder #200977E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 505 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bair Hugger 505

  • Page 1 Check the Bair Hugger therapy website to ensure you have the most recent version of this document. www.bairhugger.com reorder #200977E Bair Hugger* Temperature Management Unit Model 505 Operator’s Manual Betriebshandbuch für Bair Hugger* Bruksanvisning till Bair Hugger* Návod k obsluze jednotky regulace Temperaturmanagement-Geräte...
  • Page 2 Bair Hugger* Temperature Management Unit Model 505 Operator’s Manual English Deutsch Français Italiano Español Português Nederlands Dansk Svenska Norsk Sumoi Ελληνικά 日本語 Polski Magyar Česky Lietuvių Kalba Русский 英语...
  • Page 3: Table Of Contents

    � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � Control Panel Features of the Model 505 Temperature Management Unit �...
  • Page 4: Introduction

    (with available rolling stand and sheet clip) and disposable components, including Bair Hugger forced-air blankets, Bair Paws* patient warming gowns, and the 241* blood/fluid warming set� You can use the Model 505 temperature management unit in all clinical settings including the operating room to provide patient temperature management�...
  • Page 5: Warnings

    Otherwise, injury may result� 5� To prevent tipping, clamp the Model 505 temperature management unit to an IV pole at a height that provides stability� We recommend clamping the unit no higher than 44 in� (112 cm) from the floor on an IV pole with a minimum 28 in�...
  • Page 6: Notices

    Federal law (USA) restricts this device to sale by or on the order of a licensed healthcare professional� 3� To reliably ground this Bair Hugger warming unit, only connect to receptacles marked “Hospital Only” or “Hospital Grade”� Read Before Servicing Equipment The repair, calibration, and servicing of the temperature management unit requires the skill of qualified technical personnel who are familiar with good practice for medical device repair�...
  • Page 7: Set Up And Operation

    Bair Hugger Model 505 Temperature Management Unit Operator’s Manual Set up and Operation The Bair Hugger brand Total Temperature Management system is easy to set up and to use� Follow the instructions provided with each Bair Hugger blanket or Bair Paws gown for specific information�...
  • Page 8: Temperature Management Unit

    It is designed for safe use in all areas, including the operating room� The Model 505 temperature management unit can be attached to an IV pole or to the railing on a bed� Figure D� Control panel of the Model 505 unit...
  • Page 9: Mounting The Model 505 Temperature Management Unit

    IV pole tipping, catheter site trauma, and the patient injury� using a bedrail The Model 505 unit can also hang on the edge of a bed� The safety strap is designed to loop around the bedrail, keeping the Model 505 unit safely suspended even if the unit is inadvertently dislodged from the bedrail (see Figure F)�...
  • Page 10: Attaching And Storing The Model 505 Unit Hose

    241 fluid warming, attaches by inserting the flange end at a 45° angle in the grooved blower outlet and snapping the hose into place� Press the white tab on the blower outlet to release the hose� When storing the Model 505 unit, insert the hose clip tab in the hanger slot near the blower outlet� English 200977E...
  • Page 11: General Maintenance

    10 English Bair Hugger Model 505 Temperature Management Unit Operator’s Manual General Maintenance Cabinet Cleaning 1� Disconnect the temperature management unit from the power source before cleaning� 2� Use a damp soft cloth and a mild detergent to clean the unit cabinet� Dry with a separate soft cloth�...
  • Page 12: Specifications

    Bair Hugger Model 505 Temperature Management Unit Operator’s Manual English 11 Specifications Physical Characteristics dimensions 13 in� high x 10 in� deep x 11 in� wide 33 cm high x 25 cm deep x 28 cm wide weight 13�6 lb; 6�2 kg mounting IV pole clamp, bedrail hook with safety strap;...
  • Page 13 12 English Bair Hugger Model 505 Temperature Management Unit Operator’s Manual Safety System thermostat Independent bulb and capillary overcurrent protection Dual fused input lines alarm system Over-heat: flashing red light with audible alarm; heater shuts down certifications IEC 60601-1; EN 60601-1-2; UL 60601-1; CAN/ CSA-C22�2, No�...
  • Page 14: Definition Of Symbols

    Bair Hugger Model 505 Temperature Management Unit Operator’s Manual English 13 Definition of Symbols ON/STANDBY ON (used on isolation switch) OFF (used on isolation switch) ON/OFF push button switch Temperature Control Equipotentiality plug (Ground) Fuse Attention (see appropriate documents) Dangerous Voltage...
  • Page 15 *Bair Hugger, 241, Total Temperature Management, Arizant, Arizant Healthcare, bright ideas that work, and the Bair Hugger and Arizant logos are trademarks of Arizant Healthcare Inc., registered or pending in the U.S. Patent & Trademark Office and in other countries.

Table of Contents