Introduction
The Control4® Bus Ethernet Gateway is intended for use in a Control4 system. This
device installs in a Control4 Panelized Lighting panel or in any standard DIN rail
panel with 35mm rails. The Bus Ethernet Gateway provides the communication
bridge between keypads on the RS-485 bus and the Control4 system. For RS-485
wiring topologies, refer to the Keypad Bus Wiring Guide.
Box Contents
Bus Ethernet Gateway
Warranty Card
Two (2) Pluggable Terminal Blocks
Warnings and Considerations
Improper use or installation can cause SERIOUS INJURY,
WARNING!
DEATH or LOSS/DAMAGE OF PROPERTY.
Une mauvaise utilisation ou installation peut entraîner des
ATTENTION!
blessures graves, décès ou perte / dommages à la propriété.
WARNING!
Disconnect the power for all lines feeding into the panel before
installing this device.
Assurez-vous que tous les disjoncteurs d'alimentation dans
ATTENTION!
le panneau sont éteints avant d'installer l'appareil.
IMPORTANT!
Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See "Troubleshooting."
This is an electronic device with intricate components.
IMPORTANT!
Handle and install with care!
Requirements and Specifications
Prior to installing this product, ensure that the Control4 5-Slot or 2-Slot Panel or
the cabinet to house the gateway has been installed.
Bus
Ethernet
Gateway
Installation Guide
The Bus Ethernet Gateway specifications include:
Power Input
Power Consumption
Communications
Connectors
Operating Temperature
Humidity
Storage
Dimensions (HxWxD)
DIN Module Width
Weight
Shipping Weight
Front View
Figure 1. Front View
1
1
2x RS-485 pluggable connectors
2
Link/Activity LED
3
Reset button (recessed)
4
Module Status LED
5
Module ID button
Pre-Installation Instructions
Before You Install in a Control4 Panel
1
Use Composer Pro to add the Bus Ethernet Gateway to a project, define its
location in a panel, and print the panel report. See the Composer Pro User
Guide for details.
2
Install the panel following the instructions in the 5-Slot and 2-Slot Panel
Installation Guide.
48VDC
1.5w
10/100 Ethernet
One (1) Ethernet, RJ-45
Two (2) RS-485 Pluggable
Terminal Blocks
36AWG to 14AWG (.14mm to
1.5mm)
32˚F to 104˚F (0˚C to 40˚C)
5% - 95%
Non-condensing
-4˚ F - 158˚ F
(-20˚ C - 70˚ C)
4.23" x 4.48" x 2.32" (107.5mm x
113.9mm x 59mm)
6M
1.15 lbs. (.521 kg)
1.55 lbs. (.70 kg)
2
3
5
4

Advertisement

loading

Summary of Contents for Control 4 C4-DIN-BEG

  • Page 1 Installation Guide Two (2) RS-485 Pluggable Terminal Blocks 36AWG to 14AWG (.14mm to Supported Model 1.5mm) 32˚F to 104˚F (0˚C to 40˚C) Operating Temperature C4-DIN-BEG Bus Ethernet Gateway Humidity 5% - 95% Non-condensing Introduction Storage -4˚ F - 158˚ F (-20˚...
  • Page 2 NOTE: To remove the module, push the module toward the bottom, rotate Before You Install in a Third-Party DIN Rail Panel the module up, and lift it off. Install the third-party panel according to the third-party instructions. On the top of the Bus Ethernet Gateway, connect the Ethernet CAT5 cable to the RJ-45 port.