Download Print this page
Nortek Security & Control 2GIG 2GIG-GB1-345 Manual

Nortek Security & Control 2GIG 2GIG-GB1-345 Manual

Glass break detector

Advertisement

Quick Links

2GIG-GB1-345
GLASS BREAK DETECTOR
INSTALLATION INSTRUCTIONS
The Glass Break Detector (2GIG‐GB1‐345) is a fully‐supervised, 
tamper‐protected, ceiling‐ or wall‐mounted unit. It communicates 
with the control panel using the 345 MHz frequency. The detector 
provides a 15 ft (4.6 m) maximum detection range, 360° maximum 
horizontal sensing angle, and dual‐stage glass break detection. 
Contents
Verify that the package includes the following:
• 1—Glass Break Detector (with Mounting Base)
• 2—Lithium Batteries
• 3—Plastic Wall Anchors with Screws
Figure 1 LED Indicators
A RED LED
B
GREEN LED
C
TEST button
D Imprinted arrow (for alignment of cover and base)
Inserting and Replacing the Batteries
To insert or replace the batteries:
Unwrap the detector. 
1
Holding the cover and base, twist the cover in a counter‐clockwise 
2
motion. When the imprinted arrows on the side of the detector 
are aligned, separate the unit. 
Remove the old batteries. 
3
Always dispose and/or recycle used batteries in 
IMPORTANT:
accordance with the hazardous waste recovery and recycling 
regulations for your location. Your city, state, or country may 
also require you to comply with additional handling, recycling, 
and disposal requirements. 
Insert the batteries in the compartment. Always match the plus (+) 
4
sign on the battery with the flat side of the compartment and the 
minus (‐) sign on the battery with the spring side of the 
compartment.
It takes approximately five (5) seconds for the detector to power 
ON.
Figure 2 Glass Break Detector
A
Tamper switch
B
Battery compartments (RED tabs located behind compartments)
If closing the detector when batteries are not present, 
NOTE:
gently push the RED tabs on the backside of the base away 
from the detector (see Figure 2  Glass Break Detector—Base).
Holding the cover, align the imprinted arrows on the detector and 
5
then twist the cover in a clockwise motion to close the unit.
Failure to follow these warnings and instructions can 
WARNING:
lead to heat generation, rupture, leakage, explosion, fire, or 
other injury, or damage. Do not insert the battery into the 
compartment in the wrong direction. Always replace the 
battery with the same or equivalent type (see "Specifications" 
on page 2). Never recharge or disassemble the battery. Never 
place the battery in fire or water. Always keep batteries away 
from small children. If batteries are swallowed, promptly see 
a doctor. 
Wall Mounting
When wall mounted, the detector provides protection coverage on 
the opposite or adjacent window. Windows on the same wall as the 
detector are not protected.
To mount the detector to a wall:
1
If not already installed, insert the batteries (see "Inserting and 
Replacing the Batteries" on page 1). 
With the cover off, place the base of the detector on the adjacent 
2
or opposite wall from the window being protected.
Use the three (3) Plastic Wall Anchors (provided) to mount the 
3
base of the detector to the wall. 
Always mount the detector so the Test button is in 
IMPORTANT:
the downward position.
Holding the cover, align the imprinted arrows. Then use a 
4
clockwise twist motion to lock the cover into place. 
Copyright © 2015 Nortek Security & Control LLC
Base
1

Advertisement

loading

Summary of Contents for Nortek Security & Control 2GIG 2GIG-GB1-345

  • Page 1 2GIG-GB1-345 GLASS BREAK DETECTOR INSTALLATION INSTRUCTIONS — Figure 2 Glass Break Detector Base The Glass Break Detector (2GIG‐GB1‐345) is a fully‐supervised,  tamper‐protected, ceiling‐ or wall‐mounted unit. It communicates  with the control panel using the 345 MHz frequency. The detector  provides a 15 ft (4.6 m) maximum detection range, 360° maximum  horizontal sensing angle, and dual‐stage glass break detection.  Contents Verify that the package includes the following: • 1—Glass Break Detector (with Mounting Base) • 2—Lithium Batteries • 3—Plastic Wall Anchors with Screws Figure 1 LED Indicators Tamper switch Battery compartments (RED tabs located behind compartments) If closing the detector when batteries are not present,  NOTE: gently push the RED tabs on the backside of the base away  from the detector (see Figure 2  Glass Break Detector—Base). Holding the cover, align the imprinted arrows on the detector and  then twist the cover in a clockwise motion to close the unit. Failure to follow these warnings and instructions can  WARNING: lead to heat generation, rupture, leakage, explosion, fire, or ...
  • Page 2 Glass Break Detector | Installation Instructions Glass Type and Thickness REGULATORY INFORMATION The minimum size and shape for all glass types is 11 x 11 in (28 x 28  cm) square. Glass must be framed in the wall of the room or  mounted in a 36 in (91 cm) barrier. Figure 3 Glass Type and Thickness FCC Notice This device complies with Part 15 of the FCC's Rules. Operation is  subject to the following two conditions: This device may not cause harmful interference, and Type Minimum to Maximum Thickness This device must accept any interference received, including  Plate 1/8 ‐ 1/4 in (3.2 ‐ 6.4 mm) interference that may cause undesired operation. Tempered 1/8 ‐ 1/4 in (3.2 ‐ 6.4 mm) Sealed Insula ng† 1/8 ‐ 1/4 in (3.2 ‐ 6.4 mm) This equipment has been tested and found to comply with the limits  for a Class B digital device, pursuant to Part 15 of the FCC Rules.  † Sealed insula ng glass types are protected only if both plates of glass are broken. These limits are designed to provide reasonable protection against ...
  • Page 3 LIMITED WARRANTY This Nortek Security & Control LLC product is warranted against  defects in material and workmanship for two (2) years. This warranty  extends only to wholesale customers who buy direct from Nortek  Security & Control LLC or through Nortek Security & Control LLC’s  normal distribution channels. Nortek Security & Control LLC does not  warrant this product to consumers. Consumers should inquire from  their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Nortek Security &  Control LLC for consequential damages arising out of or in connection  with use or performance of this product or other indirect damages  with respect to loss of property, revenue, or profit, or cost of removal,  installation, or reinstallation. All implied warranties for functionality,  are valid only until the warranty expires. This Nortek Security &  Control LLC Warranty is in lieu of all other warranties expressed or  implied. 2GIG 1950 Camino Vida Roble, Suite 150 Carlsbad, CA 92008 USA For technical support in the USA and Canada: 855‐2GIG‐TECH (855‐244‐4832) Email: 2gigtechsupport@nortek.com Visit web site for technical support hours of operation For technical support outside of the USA and Canada: Contact your regional distributor Visit dealer.2gig.com for a list of distributors in your region 10004955 Rev. A A Nortek Company Copyright © 2015 Nortek Security & Control LLC...