Power
RMS Long-Term
RMS Idle
Peak
Table 1 - Single cabinet current draw
Current draw for the CS118 is dynamic and fluctuates as operating levels change.
The CS Power Distribution Sysytem (PDS, 914-0002 - 110 V/914-0003 - 230 V) provides six individually
protected AC circuits of 208/230 V, 16 A. When using the Adamson PDS, you can link a maximum of four
CS118 loudspeakers per circuit.
When wiring an AC cable for use with this product in
a single-line system, use the wiring scheme described
below in Table 2 and illustrated with Fig. 1. All work
must be completed by a qualified technician.
powerCON True1 AC Cable Input Connector
User Manual
100 V
115V
4.14 A
3.60 A
1.04 A
0.90 A
25.30 A
22.00 A
Hot or Live (L)
Neutral (N)
Protective Earth /
Ground (E or PE)
Table 2
120 V
208 V
230 V
3.45 A
1.99 A
1.80 A
0.86 A
0.50 A
0.45 A
21.08 A
12.16 A
11.00 A
Blue
Brown
Blue
Green and Yellow
powerCON True1 AC Output Cable Connector
240 V
1.73 A
0.43 A
10.54 A
Green and Yellow
Brown
Fig. 1