CHARDER MEDICAL MBF6000 User Manual

CHARDER MEDICAL MBF6000 User Manual

Body composition analyzer

Advertisement

Quick Links

USER MANUAL
MBF6000 / MBF6010
Body Composition Analyzer
Please keep the instruction manual at hand all the time for future reference.
1

Advertisement

Table of Contents
loading

Summary of Contents for CHARDER MEDICAL MBF6000

  • Page 1 USER MANUAL MBF6000 / MBF6010 Body Composition Analyzer Please keep the instruction manual at hand all the time for future reference.
  • Page 2 Explanation of Graphic Symbols on Label/Packaging Caution, consult Authorized accompanying documents representative in the before use European Community Manufacturer of medical Indicates that device device conforms to International Organization of Legal Metrology (Class III) requirements Manufacturing year of Indicates that device medical device conforms to 2014/31/EU Non...
  • Page 3 Warning During measurement, this machine will send a low level imperceptible electrical current throughout the body. Individuals with implanted medical devices, such as: 1. Pacemakers 2. Electronic lungs and other electronic medical life support equipment 3. ECG devices must not use this machine, as the electric current may affect the implanted device, endangering lives.
  • Page 4: Table Of Contents

    CONTENTS I. Safety Notes ................5 A. General Information ............. 5 B. EMC Guidance and Manufacturer's Declaration ......9 II. Installation ................13 A. Assembly ................13 B. Inserting Batteries ............. 14 C. Using Adapter ..............17 D. Attaching Height Rod to Column .......... 18 E.
  • Page 5: Safety Notes

    I. Safety Notes A. General Information Thank you for choosing this Charder Medical device. It is designed to be easy and straightforward to operate, but if you encounter any problems not addressed in this manual, please contact your local Charder service partner.
  • Page 6 Batteries should be kept away from children. If swallowed, promptly  seek medical assistance. Expected service life: 5 years.  Always comply with appropriate regulations when using electrical  components under increased safety requirements. Improper installation will render the warranty null and void. ...
  • Page 7 replacement unit. Should the repairs or replacement delivery fail, statutory provisions shall be valid. The period of warranty shall be two years, beginning on the date of purchase. Please retain your receipt as proof of purchase. No responsibility shall be accepted for damage caused through any ...
  • Page 8 Caution Usage of Results The MBF6000/MBF6010 is not a diagnostic device.  BIA results are calculated based on impedance values validated with  representative population studies and statistical analysis. As such, the technique is best suited for tracking progress for an individual over a period of time, or for categorizing large groups of people, rather than used as a one-time analysis.
  • Page 9: Emc Guidance And Manufacturer's Declaration

    B. EMC Guidance and Manufacturer's Declaration Guidance and manufacturer’s declaration-electromagnetic emissions The MBF6000/MBF6010 Body Composition Analyzer is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
  • Page 10 Guidance and manufacturer’s declaration-electromagnetic immunity The MBF6000/MBF6010 Body Composition Analyzer is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. IEC 60601...
  • Page 11 Guidance and manufacturer’s declaration-electromagnetic immunity The MBF6000/MBF6010 Body Composition Analyzer is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that is used in such an environment. IEC 60601 test...
  • Page 12 Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. Recommended separation distance between portable and mobile RF communications equipment and the MBF6000/MBF6010 Body Composition Analyzer The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
  • Page 13: Installation

    II. Installation A. Assembly 1. Remove base and column from box NOTE: remove entire device (column + platform) from box at the same time. Do not lift column by itself, as this may damage wire connecting measurement platform to indicator. 2.
  • Page 14: Inserting Batteries

    B. Inserting Batteries 1. Open battery housing cover 2. Accessing batteries Take out the battery housing 3. Use either rechargeable battery pack, or AA batteries 4. Ensure batteries are installed into the housing correctly...
  • Page 15 Rechargeable Battery Housing AA-size Battery Housing 5. Install the battery housing into the compartment, and make sure the right side of housing pin is facing towards inside of the connecting position...
  • Page 16 6. Slide back the cover to close the battery housing compartment. Turn on power to confirm that battery is correctly installed. Using Rechargeable Battery (optional) The rechargeable battery should be recharged at least once every 3 months, regardless of if the device has been used. Battery can be charged by plugging device's exclusive adapter into AC Connector Port.
  • Page 17: Using Adapter

    C. Using Adapter 1. Connect adapter to indicator before connecting to mains power supply 2. Disconnect adapter from mains power supply before unplugging adapter pin from indicator. AC Connector Port...
  • Page 18: Attaching Height Rod To Column

    D. Attaching Height Rod to Column 1. Assemble two brackets on the column Item Name Quantity M5x0.8x11 round head screw Relief Bushing Bracket for HM200D/HM201D/HM201M * Photo of display for reference only. Please refer to the actual product.
  • Page 19 2. Attach Height Rod to bracket and tighten screws. Item Name Quantity Height Rod (Compatible with: HM200D/HM201D/HM201M) M5x10L flat head screw Fixing block M5x0.8x11 * Photo of display for reference only. Please refer to the actual product.
  • Page 20 3. Connect height rod to MBF6000/6010 (HM200D or HM201D only) Digital height rod data transmission port on indicator...
  • Page 21: Attaching Thermal Printer

    E. Attaching Thermal Printer Item Parts M5*15L head screw Screws for printer bracket Printer bracket...
  • Page 22 1. Install the side bracket 2. Install the thermal printer on the bracket...
  • Page 23: Exterior And Panel

    III. Exterior and Panel A. Quick Guide to components A: Remote display (DP3710) B: Digital LCD C: Keypad D: Foot Electrodes E: Measurement Platform F: Adjustable feet G: Battery Type...
  • Page 24: Indicator And Key Functions

    B. Indicator and Key Functions Key Function 1. ON/OFF: Power on or power off. 2. ZERO: Reset display to 0.0 kg display. (can be used if within ±2% of full capacity). Press and hold for 3 seconds to enter device settings. 3.
  • Page 25: Display Layout

    C. Display layout...
  • Page 26: Using Device

    IV. Using Device A. Setup Device for Measurement To conduct a Body Composition Analysis using the MBF6000/MBF6010, the subject's height, age, and gender needs to be input prior to measurement. 1. Press the [ON/OFF] key. “0.0” will appear on the upper portion of the display.
  • Page 27: Pre-Tare

    B. Pre-Tare The Pre-Tare function is used to subtract the known weight of a substance prior to weighing. DESCRIPTION EXAMPLE Press [PRE-TARE] key. Left-most digit will begin blinking. If no further action is taken within 6 seconds, indicator will return to normal mode While digit is blinking: Enter pre-tare weight using 0~9...
  • Page 28: Conduct Measurement

    C. Conduct Measurement 1. When subject's data (gender, height, age) has been input, indicator will display a flashing arrow next to STEP ON when ready. 2. Instruct subject to step on the four electrodes of platform with bare feet. Subject should stand in a stable position without bending your knees.
  • Page 29: Measurement Results Explained

    E. Measurement Results Explained BMI (Body Mass Index) BMI is a commonly used index by the World Health Organization (WHO), utilizing height and weight to classify underweight, normal, over, and obesity in adults. Category BMI (kg/m Risk of obesity-related disease Under <...
  • Page 30 growth, brain function, and nerve function. BMR tends to decrease with age or reduction in weight, and is positively correlated with increase in muscle. TBW (Total Body Water) Total Body Water (TBW) refers to the water contained in the tissues, blood, bones, and elsewhere.
  • Page 31 MM (Muscle Mass) Increase in muscle mass increases BMR, which in turn allows the body to burn calories more quickly. PM (Protein Mass) The total amount of protein in the body. SM (Skeletal Muscle) Cardiac muscle, smooth muscle, and skeletal muscle are the three major muscle types found in the body.
  • Page 32 IMPEDANCE In the conventional 4-electrode foot-to-foot BIA method, current is supplied from the electrodes at the tips of the toes on both feet, with the voltage measured on the heel. This current flows from one lower limb through the lower abdomen and then into the other lower limb, and the bioelectrical impedance is measured.
  • Page 33: About Bioelectrical Impedance Measurement

    F. About Bioelectrical Impedance Measurement The MBF6000/MBF6010 uses Bioelectrical Impedance Analysis (BIA) to calculate body composition. At its core, BIA operates by treating the human body as an electrical conductor within an alternating current circuit, from which the alternating current resistance and impedance is measured.
  • Page 34 Perspiration can result in a temporary change in body composition measurements, as the accuracy of BIA depends largely upon interpretation of measured impedance values, which are affected greatly by hydration levels. 4. Perform the measurement under normal temperature conditions (24-28°C) Extreme temperatures (both hot and cold) can result in temporary physiological changes.
  • Page 35: Device Setup

    V. Device Setup A. Setting Time & Date 1. Press [ON/OFF] key to power on the device. 2. Press [TIME] key once. 3. The date input screen will appear. The upper row of numbers represents years (YYYY). 4. Input year in the flashing space. Press [TIME] to enter the date.
  • Page 36: Device Setup

    B. Device Setup When the device is switched on, press and hold the [ZERO] key for about 3 seconds, until the display shows the "SETUP”, followed by "A.OFF” (first option in setting menu). In device setup menu: [PRE-TARE] to toggle next menu option [ZERO] to toggle previous menu option [TIME] to confirm selection / enter submenu After selecting menu option:...
  • Page 37 Bluetooth (optional): If device has Bluetooth module installed, Bluetooth function can be turned on or off. Press [TIME] to toggle on/off, and [PRE-TARE] key to confirm selection. Wi-Fi (optional): If device has Wi-Fi module installed, Wi-Fi function can be turned on or off. Press [TIME] to toggle on/off, and [PRE-TARE] key to confirm selection.
  • Page 38: Setup Usb Connection To Pc

    VI. Setup USB Connection to PC A. Hyper Terminal For successful connection, PC hardware connected to device must be compatible with USB 2.0 or above. Operators should select a USB cable length that is most suitable to the operating environment. 1.
  • Page 39 6. Port Settings for Printout Input printer port parameter settings as below: - Baud rate: 9600 bps - Parity check: none - Data length: 8 bits - Stop bit: 1 bit - Handshake: RTS/CTS - Date code: ASCII Click [OK] to complete settings. Charder 7.
  • Page 40: Wireless Connection

    VII. Wireless Connection If the MBF6000/MBF6010 is a wireless model, the indicator can transmit measurement results wirelessly. Please see Charder wireless or bluetooth software for details. Device should be integrated with systems by qualified distributor only.
  • Page 41: Troubleshooting

    VIII. Troubleshooting Product Defects Charder's warranty is effective for the original purchaser of this device, subject to the terms and conditions listed in the Warranty Program & Return Policy. 1. If Charder is responsible for a fault or defect present upon receipt of the unit, Charder shall either repair the fault, or supply a replacement unit.
  • Page 42 Device may not function properly on soft surfaces such as carpets or  lawns. Relocate device to location with solid, stable floor If the steps above cannot resolve the problem, re-calibration may be  required to correct weighing accuracy 3. Connection failure for data transmission to PC or printer Ensure wires are connected correctly between indicator and PC or ...
  • Page 43 Error Messages Error Message Reason Action Low battery warning Replace batteries, or Voltage of battery is too plug in adapter low to operate device Overload Reduce weight on Total load exceeds measurement device's maximum platform and try again capacity Counting Error (too Error normally caused high) by faulty loadcell or...
  • Page 44: Product Specifications

    IX. Product Specifications A. Device Information Model MBF6000 / MBF6010 Weight Capacity 300 kg x 0.1 kg Measurement Weight Unit kg (OIML) , kg / lb (CE model) LCD Screen 0.8-inch LCD screen (Three row LCD) On/Off, Zero, Pre-Tare, Body Type,...
  • Page 45: Output Items (Display And Print-Out)

    B. Output Items (Display and Print-out) MODEL MBF6000 / MBF6010 Serial Number C12345678 (example) Date/Time DD/MM/YYYY hh:mm EX: 30/10/2020 10:55 Body Type Standard / Athletic Gender Male / Female 10 ~ 80 years old / 1 year increments Height 60 ~ 210cm / 3ft ~ 7ft 11.0in...
  • Page 46: Power Adapter Standards

    C. Power Adapter Standards Warning The device is only compatible with the power adapters specified in the dashed block below.
  • Page 47 Notes _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ _______________________________________________________...
  • Page 48: Declaration Of Conformity

    X. Declaration of Conformity This product has been manufactured in accordance with the harmonized European standards, following the provisions of the below stated directives: 93/42/EEC as amended by 2007/47/EC Medical Device Directive 2014/31/EU Non-automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE marking.

This manual is also suitable for:

Mbf6010

Table of Contents