Installation - Daintree GE Tetra Stick Installation Manual

Fluorescent box sign retrofit led lighting system

Advertisement

Components
1
2
4
5
T
Measure Point
C

Installation

Prior to installation, survey the site for information regarding power and accessibility inside and outside the building. Ensure
that the branch circuit supplying the existing transformer or ballast will be within the voltage ratings of the new LED power
supply, and have a current rating not exceeding 20A, or that permitted by applicable local, state, or country electrical codes
(whichever is less).
If removal of the existing lighting equipment (see Step 2) eliminates the disconnect switch, as required by applicable local,
state, or country electrical codes; a new disconnect switch must be installed.
If required, the disconnect switch shall be installed by qualified personnel, in accordance with applicable local, state, and
country electrical codes.
Repair and seal any unused openings in the electrical enclosure. Openings greater than 12.7-mm (1/2-in) diameter require a
metal patch secured by screws or rivets and caulked with non-hardening caulk. Smaller openings may be sealed with non-
hardening caulk.
1
Turn off power and remove panel
from fluorescent box sign.
Existing socket should
be push-in double
LEDs face
contact lamp holder
front of sign
4
Orient Tetra Stick so LEDs are facing
front of sign.
1
UL certified 18 AWG (0.82 mm
2
UL certified 22-14 AWG (0.33-2.08 mm
22-18 AWG (0.33-0.82 mm
3
3
93020091 LFL-LED Sockets LineFit Light Sockets (optional)
4
Tetra
5
GE Tetra
6
6
Electrical grade RTV silicone. Examples below:
• Momentive RTV 6700 Series Silicone Rubber Adhesive Sealant
• Momentive White Blanc RTV 162 Silicone Rubber Adhesive
Sealant-Electrical Grade
• Dow Corning 3140 - Non-Corrosive Flowable (clear)
• Dow Corning 3145 - Non-Corrosive Nonflowable (clear or
gray)
• Dow Corning RTV 748 Non-Corrosive Sealant-White
Remove old
components
2
Remove old fluorescent tubes, ballast
and wiring. DO NOT remove existing
fluorescent lamp holders. Inspect
existing sockets and replace as needed.
De-energize the lamp holders.
NOTE: Follow all federal and local
regulations when disposing of neon
tubing, fluorescent tubes, transformers
and ballasts.
5
Push Tetra Stick into existing
fluorescent lamp holders.
2
) supply wire
2
) inline/IDC connectors
2
24 Volt Power Supply
®
Stick
®
Old Fluorescent
tube
Tetra Stick
3
Read the product labels to determine
Tetra Stick length required to span
width of sign based on table in the
Specifications section (pages 4-5).
See Note about support
6
Continue installing Tetra Stick fixtures.
NOTE: For horizontal installations
greater than 6ft in length, the Tetra
Stick(s) should be centrally supported.
) wire connectors or
2
F48T12HO
or F48T8HO
GETSAABBCCC71-6-1

Advertisement