  • Page 1 2 MHz Function Generator SM5060-2 User Manual...
  • Page 2 Information in this manual supercede all corresponding previous released material. Scientific continues to improve products and reserves rights to amend part or all of the specifications , procedures, equipment at any time without notice. Rev 1.0 /0717 Scientific Mes-Technik Pvt.
  • Page 3: Table Of Contents

    2 MHz Function Generator SM5060-2 Table of Contents Introduction ..…………………….……….. Technical Specifications .....….……...…..5 Front Panel Controls........... 7 Rear Panel Controls………………………..…..Operating Instructions…....……………..General Information…..…………………… Safety…..……………………...……… Operating Conditions …..………………… First Time Operation…..…………………… 11 Function Selection…..…………………… 11 Frequency Adjustment…....….…… 11 Output Amplitude & Signal Connection…..11 Trigger Output…..……………………...
  • Page 4: Introduction

    All outputs are short-circuit-proof in SM5060-2 SM5060-2 can also be used in the sweep mode with an internal or external signal source. SM5060-2 User Manual...
  • Page 5: Technical Specifications

    0.2 MHz to 2 MHz : max. 0.5 dB. Output Impedance : 50 (Front Panel) / 600 (Rear Panel) DC Offset : Variable Offset range : max. ± 2.5 V into 50 Max. ± 5 V Open circuit SM5060-2 User Manual...
  • Page 6 Approx 2.0 kg. Accessories Manual : 1 no. , BNC – BNC 1 no. , Line Cord : 1 no. Values without tolerances are intended as guidelines and represent characteristics of the average instrument. ( Subject to Change ) SM5060-2 User Manual...
  • Page 7: Front Panel Controls

    Front Panel Controls z Function Generator SM5060-2 RANGE POWER ON/OFF OFFSET -20dB -20dB SWEEP FUNC OUTPUT SPEED WIDTH VARIABLE OFFSET AMPL V1.0 20Vpp 3 13 4 5 12 POWER : Push button switch for supplying power to instrument. DIGITAL DISPLAY : Backlit LCD display for modes & frequency.
  • Page 8 When pressed the output signal gets attenuated by 20 dB fixed attenuator. When both attenuator pushbuttons are activated, a total attenuation of 40 dB results. Including the amplitude control the max. attenuation amounts to 60 dB (factor 1000). SM5060-2 User Manual...
  • Page 9: Rear Panel Controls

    SM5060-2 Power : 230V, 50Hz, 22VA (approx) Fuse : 0.15 A, Slow, 5x20mm O/P 600 W FM IN SCIENTIFIC MES-TECHNIK PVT. LTD. B-14, POLOGROUND INDL. ESTATE INDORE 452 015 INDIA O/P 600 (Banana socket) : Short -circuit-proof signal output of the generator.
  • Page 10: Operating Instructions

    RH 95% should not exceed -40 C or +70 C during transport or storage. The operational position is optional, however, the ventilation holes on the SM5060-2 must not be obstructed. Prior to calibration a preheat run of approx. 30 minutes is required.
  • Page 11: First Time Operation

    DC level. The functions are marked with the corresponding symbols. If the "OFFSET” pushbutton is activated a DC voltage level is supplied by the SM5060-2 or superimposed on the output signal. Frequency Adjustment Coarse adjustment is performed with the range keys. The desired frequency is...
  • Page 12: Trigger Output

    The output terminal of the SM5060-2 is short circuit proof. If the output of the SM5060-2 unit comes into contact with components of the circuit under test, which are carrying DC voltage, an isolating capacitor of appropriate dielectric strength should be connected in series with the output of the generator.
  • Page 13: Dc Offset

    The maximum offset voltage with open output is ± 5 V. If large DC offset is added or a large signal is added with DC offset ,make sure that the desired combination is obtained without clipping. An oscilloscope may be used for proper setting of DC offset addition. SM5060-2 User Manual...
  • Page 14: Maintenance

    . The rating of the fuse is 150 mA , 250 V , sloblo , 5x20 mm glass fuse. Do not use a fuse with a higher value other wise it may damage the instrument in case, the mains voltage goes much higher than the rating of the mains fluctuation of 10%. ± SM5060-2 User Manual...
  • Page 15: Dispatch Procedure For Service

    Dispatch the instrument (only on the receipt of our advise) securely packed in original packing duly insured and freight paid along with accessories and a copy of the faults details noticed at our Service Center listed on last page of this manual, nearest to you. SM5060-2 User Manual...
  • Page 16: Warranty Conditions

    Warranty Conditions Scientific warrants all its Instruments to be free from defects in material and workmanship when used under normal operating conditions in accordance with the instructions given in the manual for a period of 12 (Twelve) months from date of purchase from Scientific or its authorised dealers. The service during the warranty period will be rendered on return to factory /service center basis.

Table of Contents