Scientific SM5076 User Manual

3 mhz function generator counter with power supply
Hide thumbs Also See for SM5076:

Advertisement

Quick Links

3 MH
z Function generator
Counter with ower upply
P
S
SM5076 & SM5076-1
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SM5076 and is the answer not in the manual?

Questions and answers

Summary of Contents for Scientific SM5076

  • Page 1 3 MH z Function generator Counter with ower upply SM5076 & SM5076-1 User Manual...
  • Page 2 Information in this manual supercede all corresponding previous released material. Scientific continues to improve products and reserves rights to amend part or all of the specifications, procedures, equipment at any time without notice. Rev 1.2 / 1212 Scientific Mes-Technik Pvt.
  • Page 3: Table Of Contents

    3 MH z Function generator Counter with ower upply SM5076 & SM5076-1 Introduction .............. Technical Specifications .......... Front Panel Controls ..........Rear Panel Controls ..........Operating Instructions ..........General Information ........Safety ............Operating Conditions ........First Time Operation ........
  • Page 4: Mh Z Function Generator Counter With Ower Upply

    Square Wave Risetime Typ. 70 ns Counter Sensitivity 50 mV (rms) 2 x 15 V/ 1 A, 5 V/ 1 A DC Power Supply 3 digit switchable, simultaneous display for voltage & current (SM5076-1) The new SM5076 & SM5076-1 includes Function generator, Frequency counter and DC power supply.
  • Page 5: Technical Specifications

    1 : 100 approx. Input Impedance : 50 k II 25 pF Input Voltage : ± 30 V max. Internal Sweep : Sweep Speed : 20 ms to 4 s Sweep Range : approx. 1 : 100 User Manual 5076 / SM5076-1...
  • Page 6 4 digit for Function Generator and 5 digit for Frequency Counter, 0.5”, 7segment LED display. 3 digit switchable, simultaneous display for voltage & current (SM5076-1) Supply : 230V ± 10%, 50 Hz (100/120/220/240 V available on request) Operating Conditions : 0 to 50°C, RH 95%...
  • Page 7: Front Panel Controls

    User Manual 5076 / SM5076-1...
  • Page 8 User Manual 5076 / 5076-1...
  • Page 9 20 V (o.c.) or 10 V respectively when terminated with 50 . “A” banana terminals : Output terminals of 5 volt DC power supply. “B” banana terminals : Output terminals of 15 volt DC power supply. User Manual 5076 / SM5076-1...
  • Page 10: Rear Panel Controls

    Digital Display (7-segment LED) : Each 3-digit LED display for displaying voltage & current.(SM5076-1) Rear Panel Controls TRIG OUT FM IN Scientific Mes- Technik Pvt. Ltd. B- 14, Pologround Industrial Estate Indore 452015, India SM5076 Power : 230 V, 50 Hz Fuse : 0.35 A, time lag, 5x20 mm...
  • Page 11: Operating Instructions

    + 70 C during transport or storage. The operational position is optional, however, the ventilation holes on the 5076 & 5076-1 must not be obstructed. Prior to calibration a preheat run of approx. 30 minutes is required User Manual 5076 / SM5076-1...
  • Page 12: First Time Operation

    In high signal voltage ranges it should be noted that the used terminating resistor must dissipate the corresponding effective power. The output terminal of the SM5076 & SM5076-1 is short circuit proof. If the output of the SM5076 & SM5076-1...
  • Page 13: Trigger Output

    The capacitance of this isolating capacitor should be selected in such way that the frequency response of the output signal is not affected over the whole frequency range of the SM5076 & SM5076-1 unit. Trigger Output In the sine, square and triangle modes, the trigger output (at back panel) supplies a square signal in synchronism with the output signal.
  • Page 14: Iii) Dc Offset

    15 V power supplies can be used. Negative of one 15 V power supply may be connected with negative of another power supply, will result +ve - GND - ve. User Manual 5076 / SM5076-1...
  • Page 15: Maintenance

    Maintenance There are no user serviceable part inside S 5076 & SM5076-1 . Your S 5076 & SM5076-1 3 M z Function Generator is thoughtfully engineered for ease of use, accuracy and reliability. The instrument is carefully tested and calibrated using standards traceable to National Laboratories.
  • Page 16: Despatch Procedure For Service

    Service Center listed on last page of manual nearest to you. User Manual 5076 / SM5076-1...
  • Page 17: Warranty Conditions

    Warranty Conditions 1. Scientific warrants all its Instruments to be free from defects in material and workmanship when used under normal operating conditions in accordance with the instructions given in the manual for a period of 12 (Twelve) months from date of purchase from Scientific or its authorised dealers.
  • Page 18 Notes: User Manual 5076 / SM5076-1...
  • Page 19 Notes: User Manual 5076 / SM5076-1...
  • Page 20: List Of Service Centers

    "Krupa Ashirwad Complex", Fax : (040)27534996 2nd Floor, Door No.5-2-394 hyderabad@scientificindia.com 81/A, R.P. Road, Hyderbasti Secunderabad 500026 Scientific Mes-Technik Pvt. Ltd., Ph : (033) 2228 2223-6 2, Chowringhee Road, Fax : (033)2228 1713 Kolkata 700 013 kolkata@scientificindia.com User Manual SM5076 / SM5076-1...

This manual is also suitable for:

Sm5076-1

Table of Contents