Structure Dcip 650-01 - SSS Siedle DCIP 650-01 Manual

Doorcom ip in-home
Table of Contents

Advertisement

3 Structure DCIP 650-01

In-Home bus: Video
Audio and video communication via IP
In-Home-bus: Video
BVVU 650-...
BVVU 650-...
BVVU 650-...
DCIP 650-...
In-Home bus link
The DCIP 650­... behaves in the
system in the same way as one or
more bus telephones with video
and is consequently bound by the
same system limitations (range and
number of users).
The DCIP 650­... comprises the com­
ponents:
• SIVS 610-..., system interface video
server. Processing and adjustment of
data, audio and video.
• SII 650-... system interface
In­Home. Interface to Siedle
In­Home bus.
• IPVS 600-..., IP video server.
Processing and adjustment of audio
and video, transmission of data,
audio and video to the IP network.
One DCIP 650­... each is required
per door. A maximum of 29 different
call destinations can be dialled.
Dialling is possible by means of a call
button module, code lock module or
display call module.
• Bus programming software
BPS 650­... V2.50 for programming
• Software Client DCIP SC 600-... for
installation on PC users intended to
receive door calls.
4
VNG 602-...
PRI 602-... USB
Power supply
The DCIP 650­... is supplied com­
pletely via the video line rectifier
VNG 602-... . Connection takes
place at the SIVS 610­...
An optionally connected
DCA 740­01 is also supplied from
the SIVS 610­... . The a/b public
network interface is supplied from
the TC system. It is not possible to
connect an individual public network
telephone directly to the a/b line of
the DCA 740­01.
Functions
• Door call from the In-Home bus
and signalling
• Text display of which door or
which bus telephone is calling.
• Door release actuation
• Light actuation
• Direct dialling and connection to
a door station or a bus telephone.
• Initiation of switching or control
functions
• Reception of status messages from
the In­Home bus
Mounting and installation
Connection of the DCIP 650­...
to the In­Home bus takes place at
IPVS 600-...
TCP/IP-Network
terminals TaM/TbM at the SII 650­...
on the monitor branch. Dual termi­
nals TaM/TbM are provided for loop
through. Connection can alterna­
tively take place using a distributor
BVVU 650­... . The devices are
intended for switch panel mounting.
These should preferably be mounted
directly one next to the other.
The maximum conductor length
for device connection between
SIVS 610­... and SII 650­... may be
1 metre. The SII 650­... is linked to
the SIVS 610­... with 6 cores.
Commissioning and
programming
After connection of the supply
voltage, the devices SII 650-... and
SIVS 610-... can be programmed
with the aid of a PRI 602-... via the
PC.
Prior to commissioning the
DoorCom IP, the entire In-Home
system must be programmed.
The components SII 650­...,
SIVS 610-... and BVNG 650-... which
are in the same line must have the
same address set. Programming of
the SIVS 610­... and SII 650­... takes

Advertisement

Table of Contents
loading