Download Print this page
Sealey SCS00 Instruction Manual
Sealey SCS00 Instruction Manual

Sealey SCS00 Instruction Manual

Advertisement

Quick Links

SCS00 SCS01.V2 SCS02.V2 SCS03
MODEL NOS:
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY,
AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE REFERENCE.
1.
INTRODUCTION
Heavy-duty construction with twin locking bolts. Simple to operate electronic keypad accepts a combination of
between three and eight numbers, giving millions of combinations. Three LEDs show security, power and
operating status. Includes battery back-up and manual override. SCS03 is supplied with two shelves and four
support feet. Powder coated finish. Compact design, pre-drilled holes and security fixings allow safe to be
hidden discreetly away.
2.
SECURITY
To reduce the risk of theft securely attach the safe to a floor or wall.
CAUTION: If you, or an intruder, uses an incorrect group of numbers, the safe will not open and a yellow
light will illuminate. Entering an incorrect PIN 3 times will freeze the system for 20 seconds.
Keep the safe key and any record of the code separate from the safe and unidentified.
3.
OPERATION
2.1.
Initial opening.
2.1.1. To open door of safe for the first time press, in turn, key pads 1-5-9-B.
2.1.2. Within 5 seconds of correct code entry turn knob clockwise to open the safe door.
2.1.3. If the safe relocks, please enter PIN again. Don't forget to press the letter "B" when entering PIN.
2.2.
Entering a new code.
The code must consist of between 3 and 8 numbers and should be safely recorded before
being entered into the safe electronics.
2.2.1 Open safe by inputting the factory preset PIN (i.e.159B).
2.2.2 Press the red button on the inside of the door near the hinges.
2.2.3 Now enter your PIN digits, and then press the letter "B" to confirm your PIN.
A beep will sound for each key pressed. After the letter "B" is
pressed, a green light will show to indicate your success. Be
sure to write down this code immediately, so you do not forget.
2.3.
Low battery warning and replacement.
2.3.1 A red light showing on the top right of the control panel indicates
low batteries. Change batteries by removing the sliding battery
housing cover at the back of the door, then replace all batteries.
2.3.2 If the digital lock does not work because of the low battery
condition, use the override key to open the safe, and then replace all batteries.
2.4.
Key operation.
2.4.1 If you forget your code, you can use the manual override key: DO NOT keep override key in safe. The
override lock is situated under the logo panel in the centre of the main control panel. Prise out the panel
using a small screwdriver. Turn key anticlockwise and the safe will be open. Snap panel back into place afterwards.
2.4.2 Please make a note of the following details and keep independent of safe: The Key Number and the Safe
Number (The safe number is on a small sticker either beside the override lock or on the inside of the door).
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and
component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our
catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
I N S T R U C T I O N M A N U A L F O R :
ELECTRONIC COMBINATION
S E C U R I T Y S A F E S
01284 757500
Web address: www.sealey.co.uk
01284 703534
E-mail: sales@sealey.co.uk
SCS00,SCS01.V2, SCS02.V2,SCS03 - 1 - 060505
SCS00 SCS01.V2 SCS02.V2 SCS03
MODEL NOS:
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY,
AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE REFERENCE.
1.
INTRODUCTION
Heavy-duty construction with twin locking bolts. Simple to operate electronic keypad accepts a combination of
between three and eight numbers, giving millions of combinations. Three LEDs show security, power and
operating status. Includes battery back-up and manual override. SCS03 is supplied with two shelves and four
support feet. Powder coated finish. Compact design, pre-drilled holes and security fixings allow safe to be
hidden discreetly away.
2.
SECURITY
To reduce the risk of theft securely attach the safe to a floor or wall.
CAUTION: If you, or an intruder, uses an incorrect group of numbers, the safe will not open and a yellow
light will illuminate. Entering an incorrect PIN 3 times will freeze the system for 20 seconds.
Keep the safe key and any record of the code separate from the safe and unidentified.
3.
OPERATION
2.1.
Initial opening.
2.1.1. To open door of safe for the first time press, in turn, key pads 1-5-9-B.
2.1.2. Within 5 seconds of correct code entry turn knob clockwise to open the safe door.
2.1.3. If the safe relocks, please enter PIN again. Don't forget to press the letter "B" when entering PIN.
2.2.
Entering a new code.
The code must consist of between 3 and 8 numbers and should be safely recorded before
being entered into the safe electronics.
2.2.1 Open safe by inputting the factory preset PIN (i.e.159B).
2.2.2 Press the red button on the inside of the door near the hinges.
2.2.3 Now enter your PIN digits, and then press the letter "B" to confirm your PIN.
A beep will sound for each key pressed. After the letter "B" is
pressed, a green light will show to indicate your success. Be
sure to write down this code immediately, so you do not forget.
2.3.
Low battery warning and replacement.
2.3.1 A red light showing on the top right of the control panel indicates
low batteries. Change batteries by removing the sliding battery
housing cover at the back of the door, then replace all batteries.
2.3.2 If the digital lock does not work because of the low battery
condition, use the override key to open the safe, and then replace all batteries.
2.4.
Key operation.
2.4.1 If you forget your code, you can use the manual override key: DO NOT keep override key in safe. The
override lock is situated under the logo panel in the centre of the main control panel. Prise out the panel
using a small screwdriver. Turn key anticlockwise and the safe will be open. Snap panel back into place afterwards.
2.4.2 Please make a note of the following details and keep independent of safe: The Key Number and the Safe
Number (The safe number is on a small sticker either beside the override lock or on the inside of the door).
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and
component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our
catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
I N S T R U C T I O N M A N U A L F O R :
ELECTRONIC COMBINATION
S E C U R I T Y S A F E S
01284 757500
Web address: www.sealey.co.uk
01284 703534
E-mail: sales@sealey.co.uk
SCS00,SCS01.V2, SCS02.V2,SCS03 - 1 - 060505

Advertisement

loading

Summary of Contents for Sealey SCS00

  • Page 1 MODEL NOS: Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
  • Page 2 Date: 7th January 2005 89/336/EEC EMC Directive 89/336/EEC EMC Directive For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products. For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products. Sole UK Distributor 01284 757500...

This manual is also suitable for:

Scs01.v2Scs02.v2Scs03