MSA V-TEC io1 User Instructions
MSA V-TEC io1 User Instructions

MSA V-TEC io1 User Instructions

Fall protection

Advertisement

Quick Links

User Instructions
V-TEC® io1
Fall Protection
Order No.: 10215637_r0
Print Spec: 10000005389 (R)
CR: 800000043205
MSA safety .com

Advertisement

Table of Contents
loading

Summary of Contents for MSA V-TEC io1

  • Page 1 User Instructions V-TEC® io1 Fall Protection Order No.: 10215637_r0 Print Spec: 10000005389 (R) CR: 800000043205 MSA safety .com...
  • Page 2 The warranties made by MSA with respect to the product are voided if the product is not installed and used in accordance with the instructions in this manual. Please protect yourself and your employees by following the instructions.
  • Page 3: Table Of Contents

    Electrical Specifications Installation Installing the V-TEC io1 Installing the RFID Tag Operation Using the V-TEC io1 System 5.1.1 Connecting the V-TEC io1 system to the D-ring 5.1.2 Sleep Mode 5.1.3 Battery Service Life 5.1.4 Charging the io1 Status Indicators Inspection...
  • Page 4: Safety Regulations

    Device is not Intrinsically Safe. Do NOT use this device in flammable or explosive environments. • Use the io1 only with the MSA V-TEC PFL and an MSA harness with the RFID tag installed. Do NOT attach to other products.
  • Page 5: Description

    2 Description Description The V-TEC io1 system consists of a V-TEC PFL and a permanently integrated io1 component on the snaphook that monitors and communicates connection status between the snaphook and an MSA harness with an RFID tag attached. This manual covers instructions and warnings on installation of the V-TEC io1 system and use of the io1.
  • Page 6 2 Description Figure 1 V-TEC io1 Components V-TEC io1 System V-TEC PFL io1 Component Snaphook RFID Tag Carabiner Charging Kit V-TEC® io1...
  • Page 7: Specifications

    3 Specifications Figure 2 Installed RFID Tag Figure 3 Installed V-TEC io1 RFID Tag Specifications Physical Specifications Capacity 310 lbs (141 kg) Anchorage Strength 3,600 lbf (16 kN) Dimensions 13.5" x 3.4" x 2.75" Product Weight V-TEC io1 Only: 2.4 lbs Entire Product Kit: 4.8 lbs...
  • Page 8: Electrical Specifications

    Battery Capacity: 350mAh LiPo/nom. 3.7V Charge Current: 150mA Charge Threshold: 35mA For PFL, Rescue, Training, and Inspection content related to the lanyard itself, please reference included PFL manual, MSA P/N 63011-96. Installation Installing the V-TEC io1 WARNING! • Before wiring the V-TEC io1, disconnect power from the PIT.
  • Page 9 NOTE: Confirm this location has the required clearance between the control wall and the panel that will be placed over it. Mount the V-TEC io1 system onto overhead fall protection rail. NOTE: Do NOT permanently fix the carabiner in place. It must be able to slide freely.
  • Page 10 4 Installation Connect the 10’ USB cable to the USB C port on the back of the io1. Route the cable back to the cabin pillar and secure it in the upper corner near the roof leaving some slack in the cable as shown. NOTE: Use the provided cable ties and peel and stick cable tie mounts as needed.
  • Page 11: Installing The Rfid Tag

    NOTE: The two assembly screws are captured and should not be fully removed for disassembly. Position the main body of the RFID carrier at the center of the base of the D-ring. Ensure the MSA logo is right side up.
  • Page 12: Operation

    Failure to follow this warning can result in serious personal injury or death. If after several tries the io1 is still red when the attached to the D-ring, use a paperclip to reset the device or contact MSA Customer Service. See 7 Troubleshooting for more information on resetting the io1.
  • Page 13: Sleep Mode

    5 Operation 5.1.2 Sleep Mode When the io1 does not detect motion, the device enters sleep mode. The io1 “wakes up” when it detects motion. 5.1.3 Battery Service Life When the battery has 20% service life remaining, the io1 pulses red at 3 second intervals until it is plugged in to charge. 5.1.4 Charging the io1 Park the order picker truck.
  • Page 14: Inspection

    Inspect labels to ensure they are present and all information is legible. The labels should be free from abrasions or peeling. See MSA V-TEC PFL Manual, MSA P/N 63011-96 (included in box) for Retractable Lanyard portion. Troubleshooting If the io1 is not working, perform a hard reset. See Table 1 for status indicators.
  • Page 15: Warranty

    Exclusive Remedy – It is expressly agreed that the Purchaser’s sole and exclusive remedy for breach of the above warranty, for any tortious conduct of MSA, or for any other cause of action, shall be the repair and/or replacement, at MSA’s option, of any equipment or parts thereof, that after examination by MSA are proven to be defective.
  • Page 16 For local MSA contacts, please visit us at MSAsafety.com...