Troubleshooting

Problem
No display
Flow rate reads zero when there is
flow
Display reads "-"
Flow rate intermittently drops when
there is flow
Jumpy reading

Spare Parts

Part No.
Description
1608474 Replacement Battery Kit
15 ft. Power/ Output Cable
1608473 25 ft. Power/ Output Cable
50 ft. power/ Output Cable
Housing Set Screw (Housing)
Housing Set Screw (PCB)
Electronic Housing Cover Ass'y Housing Cover, Glass, O-Ring and Plastic Lid (assembled)
Electronic Housing Ass'y
Tamper Seal
PCB Ass'y with LCD
Sensor Logo Sticker
Display Cover Logo Sticker
P/N 1605606 Rev A (ECN 32937)
Possible Cause
Dead battery
Flow is below cutoff
There is air in the meter
Meter is installed backwards
There is air in the meter
Improperly equalized
Pulsing flow
Rapidly changing conductivity (for
chemigation applications)
Four Battery Pack, Replacement O-Ring, 25g Silicone Grease
M5 Hex Screws (x4), M5 Spring Washers (x4)
M4 Standoffs (x4), M3 Phillips Flat Head Screws (x4)
Housing, Waterproof Connector, O-Rings and Cable Harness
14
Solution
Replace battery pack
Reading will resume when flow
increases
Reposition meter for full pipe
Note flow direction arrow, reverse
meter position
Reposition meter for full pipe or
rotate to avoid bubbles
Check for proper equalization
Use external power source (allows
more flow averaging)
Install meter upstream of the chemi-
gation entry location (or far enough
downstream for thorough fluid mix-
ing before reaching the meter)
Contents
IM3000 Installation Manual