Resistance And Voltage Conversion Table Of Sensor For Temperature - Samsung RT40MA Service Manual

Table of Contents

Advertisement

7. Reference) Resistance and voltage conversion table of sensor for temperature
The input voltage of MICOM port can be different according to the composition of H/W and its specification is
standardized using a 10㏀-F grade.
The voltage specification of relevant MICOM when the sensor is open : Around DC 5V (Vcc level)
The voltage specification of relevant MICOM when the sensor short circuits : Around DC 0V (Ground level)
Temperature
Resistance (㏀)
-35
68.648
-34
65.011
-33
61.595
-32
58.384
-31
55.366
-30
52.526
-29
49.854
-28
47.337
-27
44.967
-26
42.733
-25
40.626
-24
38.640
-23
36.765
-22
34.995
-21
33.323
-20
31.743
-19
30.250
-18
28.838
-17
27.502
-16
26.237
Voltage(v)
Temperature
4.364
00
4.333
01
4.301
02
4.268
03
4.235
04
4.2
05
4.164
06
4.127
07
4.09
08
4.051
09
4.012
10
3.972
11
3.93
12
3.888
13
3.845
14
3.802
15
3.757
16
3.712
17
3.666
18
3.62
19
32
Voltage(v)
Resistance (㏀)
12.949
12.424
11.924
11.447
10.993
10.559
10.146
9.752
9.375
9.016
8.673
8.345
8.032
7.732
7.446
7.172
6.910
6.659
6.420
6.190
2.821
2.77
2.719
2.668
2.618
2.567
2.518
2.468
2.419
2.37
2.322
2.274
2.227
2.180
2.134
2.088
2.043
1.998
1.954
1.911

Hide quick links: