CONTENT 1. General description 2. Standard behaviour Mobeye CM2410 with Mobeye SIM and Internet Portal Mobeye CM2410 with own SIM card 3. Getting started Insert the SIM card Insert the batteries 4. Programming when using the Mobeye SIM and portal...
Page 4
• Do not let it fall from height. • Do not use in an environment where any inflammable gases, vapors or dust are present or could be present. • Repair of the device may only be carried out by people, trained for Mobeye ® repair.
First of all you’ll have to choose a SIM card to place in the device. You can use the Mobeye SIM card or your own SIM card. The Mobeye SIM card provides access to the Mobeye Internet Portal. In this management environment the device is given additional functions such as online programming, status and history display, more options for forwarding messages and it will monitor test messages (keep alive).
Mobeye Internet Portal, has the following standard behaviour as factory settings: - In case the Ei Electronics fire detector activates the input 1 of the Mobeye CM2410, the alarm module sends an alarm message to the Mobeye Internet Portal and calls the phone numbers programmed in by the user.
3. GETTING STARTED To get started with the Mobeye GSM fire alarm communicator CM2410, at least the following steps need to be taken in the following order: 1. Insert the SIM card 2. Insert the batteries 3. Programming when using the Mobeye SIM/Portal a.
When using your own SIM card: Before installing the SIM card should have PIN code "0000", or PIN code removed. (A PIN code can be changed or removed by putting the SIM card in to any mobile phone and entering the 'security' menu.) NB: Make sure the SIM card is inserted before the batteries.
You will receive an e-mail to confirm the new account. After confirmation login on the portal. If you do not receive this e-mail, please check your spam box or ask Mobeye (info@mobeye.com). 4.2 REGISTER THE MOBEYE SIM CARD...
To activate the unit in the portal, the GSM module needs to be open and connected to the network. A battery-operated Mobeye GSM fire alarm communicator CM2410 switches to the program mode after placing the batteries. First the GSM module establishes network connection.
The device settings can be programmed in the Mobeye Internet Portal. In this way you prepare the settings, to be picked up by the device. Since the Mobeye device is leading in the communication between the portal and the device, the data synchronisation is done after: 1) any message to the portal (e.g.
Page 12
indicate the device. A free text is available as an internal comment field. This is not included in reports. Alarm dispatch In the block "Contacts for text and e-mail messages" you link the contact persons who receive alarm and service messages via text message and / or e-mail. Service messages can be warnings about missed test messages and low battery voltage.
This setting is only relevant when using your own SIM card: the Mobeye GSM fire alarm communicator CM2410 alerts after an alarm on the inputs with a call and an SMS. It is possible to turn off the SMS (OFF). As a factory setting, the SMS is set to...
When using the Mobeye Internet Portal: The Mobeye GSM fire alarm communicator CM2410 can send regular test messages (keep alive) to the Mobeye Internet Portal, to ensure the proper functioning of the unit. The test message will also be sent if the unit is disarmed.
6. MOUNT THE GSM MODULE HOUSING AND PERFORM A TEST 6.1 MOUNT THE GSM MODULE HOUSING TO THE CEILING Mount the housing in which the module is fixed to the desired place to the ceiling, using the plugs and screws which can be found inside the Ei Electronics box. Please refer to the manual of the Ei Electronics detector for the ideal location and installation method.
6.3 PERFORM A TEST After the previous steps, the GSM fire detector is operational. In order to execute a test, press the TEST & HUSH (or TEST & STUMM) button of the EI detector during a few seconds (this can take up to 5 seconds). Hold it for another two seconds after the siren starts sounding.
Using external power, the unit is always in program mode. 7.2 PROGRAM AT LEAST ONE TELEPHONE NUMBER The Mobeye GSM fire alarm communicator CM2410 is able to send messages up to 5 telephone numbers. The first telephone number (TEL1) belongs to the administrator.
When using your own SIM card, all settings are programmed in by SMS text messages: 1. Make sure the GSM fire alarm communicator CM2410 is in program mode (please refer to 7.1). 2. Send an SMS text message with the (security) code and the command.
Change security code INSTCODE: 0000···9999 1111 Set telephone number for TEL1: Empty alarm messages TEL5: Delete telephone number DEL1 DEL5 Mobeye Identification text NAME: 20 characters Call on/off CALL: ON, OFF SMS on/off SMS: ON, OFF Alarm text input 1...
The signal strength of the used mobile network can be requested. If the network is weak, it is advised to use a SIM card of another network provider or an external GSM antenna (a Mobeye accessory). The GSM signal strength can be requested by sending following SMS text message:...
- If applied in a network of several detectors (cabled or using RF modules), the detector with the CM2410 GSM module must be of the type Ei605C, Ei605TYC, Ei603C or Ei603TYC. The other detectors in the network can be any detector in the 600- and 650-series.
9. USE OF EXTERNAL POWER SUPPLY Although the Mobeye CM2410 is designed to run on batteries, it is possible to use an external power supply. In this mode the module is always in connection with the GSM network and therefore always in program mode. In case the power fails, the batteries take over the functioning.
1. To delete the Mobeye CM2410 from the Mobeye Internet Portal If connected to the Mobeye Internet Portal, first delete the device from the Portal. The SIM card could be then reused for another Mobeye device, or the same device can be connected again.
10.2 TECHNICAL MESSAGES In the event of technical issues the administrator receives an SMS message. Possible technical messages are: Message Reason Low batteries, external power Power is available, batteries need to be supply OK replaced. No external power supply, No external power supply, batteries are able to batteries OK take over operation in low power mode.
10.3 STATUS FEEDBACK LED pattern Status Required action Blinking green, 1 second Module not configured Configure at least one on / 1 second off telephone number. 1 green flash every 3 Module is switched on, No action required. seconds powered by batteries Green LED stays on Module is switched on, No action required.
Need help?