Controller Connection - PAW SolexMini TW Installation And Commissioning Instructions

Transfer station dn 15 hydraulics
Table of Contents

Advertisement

3 Assembly and installation [specialist]
3.1

Controller connection

Risk to life and limb due to electric shock!
 Prior to commencing electrical work on the controller, pull the mains plug!
 Only after completing all installation work as well as the flushing and filling,
Connection scheme (881)
for DHW systems and heating systems
Please observe the separate instructions regarding the controller SC5.14!
1.
Connect the temperature sensors to the controller:
Collector sensor S1
Storage tank bottom: S2
Integrated: S3, S9,
2.
Tighten all union nuts and thread connections.
The installation of the transfer station is now completed and the station can be put
into operation.
2016/05
WARNING
the mains plug of the controller can be plugged into a socket.
Thus, an unintentional start of the motors is avoided.
Connection scheme SC5.14
dV
(FlowRotor)
996091425-mub-en – V04
Connection scheme (882)
for heating systems
Collector sensor S1
Storage tank 1 bottom: S2
Storage tank 2 bottom: S4
(required on site, item no. E13180)
Integrated: S3, S9,
dV
(FlowRotor)
11