3.10.
Lift the work table, turn it diagonally so that it can be placed
in the space between the posts. Rotate the bed back to the
horizontal so that the ends are either side of each post and
lower the bed onto the two frame pins.
3.11.
Insert the pumping handle (27) into the socket at the base of
the pump (26).
4. INSTALLATION & OPERATING
4.1.
INSTALLATION.
4.1.1. Securely fix the press to a flat, firm, level surface taking into
account clearance for workpieces.
4.1.2. Before operating the press, purge the hydraulic system in
order to eliminate any air that may have built up during transit.
Open the release valve (R) by turning it anti-clockwise and
pump the handle several times to eliminate any air in the
system, then close release valve. Note: Should the system
malfunction at any time, repeating this process may resolve
the problem.
DANGER! For safety reasons, always ensure the workpiece
!
!
and press tools are secured on the table and will not flex or
suddenly "give way" causing danger to operator or the
component. Also ensure you have read and understood
Section 1 safety instructions.
4.2.
OPERATING INSTRUCTIONS.
4.2.1. Position the work table at the required operating height by
inserting the support pins into the appropriate holes in the
main frame.
4.2.2. Place the support blocks (12) onto work table (11), then
place the workpiece onto the support blocks and align
beneath the ram as required. Note: care must be taken to
ensure a support block does not fall from the press work table.
If necessary hold the configuration in position with clamps.
4.2.3. Close the release valve by turning it clockwise until it is firmly
closed.
4.2.4. Pump the handle slowly until the ram is close to, or just
touching, the workpiece. Before applying any pressure to the
workpiece, recheck the alignment with the ram and ensure
that the workpiece and press tools are supported in such a
way that they cannot flex.
4.2.5. Pump the handle to apply load onto workpiece.
4.2.6. When work is done, stop pumping the handle. Slowly and
carefully free load from workpiece by turning the release valve
anti-clockwise in small increments. Note: Always keep the
piston retracted after use to avoid ram corrosion.
4.2.7. Once ram has fully retracted, remove workpiece from work
table.
5. MAINTENANCE
Note: Maintenance and repair must only be carried out by qualified
person. Contact your Sealey dealer for details.
5.1.
Periodically lubricate all joints and moving parts.
5.2.
Always keep the press clean, dry, and protected from harsh
conditions.
Declaration of Conformity We, the sole importer into the UK, declare that the product listed below is in conformity with the following
standards and directives.
30 Ton Hydraulic Floor Press
Model: YK30F
98/37/EC Machinery Directive
93/68/EEC CE Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Quality Machinery
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
5.3.
Before checking the oil level make sure the ram is fully
retracted. Remove the oil filler plug (hex) (F) from the top of the
pump.The oil level should be just below the bottom of the filler
hole.If it needs filling, use only Sealey hydraulic jack oil. (DO
NOT use brake fluid. Contact your local Sealey dealer for
details). Replace oil filler nut and purge system of air (see 4.1.2.).
5.4.
When replacing the hydraulic oil, ensure the piston is fully
retracted.
5.5.
If press efficiency begins to drop, purge the system to eliminate
any air from the hydraulic system (see 4.1.2.).
5.6.
When not in use, store the press in a dry, childproof location
with the ram and piston fully retracted.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT
USE OF THE MACHINE.
Hydraulic products are only repaired by local service agents. We
have service/repair agents in all parts of the UK.
DO NOT RETURN PRODUCT TO US. Please telephone us on
01284 757500 to obtain the address and phone number of your local
agent. If product is under guarantee please contact your dealer.
De-commissioning Product
Should the press become completely unserviceable and require
disposal, draw off the hydraulic oil into an approved container and
dispose of the product and the hydraulic oil according to local
regulations.
The construction file for this product is held by the Manufacturer and may be
inspected, by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman.
01284 757500
01284 703534
14th June 2007
www.sealey.co.uk
Web
sales@sealey.co.uk
email

Advertisement

loading