Download Print this page

Ice-O-Matic KCUBEDISP Installation Instructions page 3

Kit used on cim series ice machines when installed in ice dispensers

Advertisement

5. Secure new red wire with supplied wire ties. 
6. Adjust the bin thermostat (see Bin Thermostat Adjustment section). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
CIM Series Thermostat Tube Bracket: 
1. Install the ice deflector assembly to the ice 
machine. Make sure that the end of the deflector 
with the thermal well is down into the bin. Secure 
with the #10 screws provided in the base.  
2. Remove the plug from the right side of the food 
zone for the installation of the bin thermostat in 
later steps. Note: The slots in the ice deflector 
are designed so that the screws in the base only 
need to be loosened, rather than completely 
 
removed.
 
 
CIM Series Bin Thermostat Installation 
1. Remove control box cover & install the bin level 
thermostat in holes provided on the control box or 
frame.  
2. Attach provided bin thermostat harness to the 
thermostat, and then route other end into the 
control box. Plug into the control board connector 
labeled bin thermostat. 
3. Route thermostat capillary tube so it does not 
interfere with any electrical or moving 
components. There is a removable plastic cap in 
the right wall of the food‐zone to run the cap tube 
9081477‐01 REV D 
 
Wiring in machine as shipped 
As wired with Bin Thermostat installed in series with 
Bin Fill Switch 
Figure 5: Bin Thermostat wiring 
 
ICE DEFLECTOR
Figure 2: CIM Deflector Installation
DIP SWITCH 
Figure 6: CIM Right Side View
BIN STAT 
CONNECTION 
BIN STAT MOUNTING 
LOCATION 
ROUTE CAP TUBE HERE
 
Page 3 of 4 