Eliminator TotalGuard Installation Manual Central Heating Filter Version 2 – January 2016 IMPORTANT Please retain these instructions for reference during servicing Page 1 Eliminator TotalGuard Instructions (26-01-16).indd 1 26/01/2016 16:39...
Safety Considerations SAFETY CONSIDERATIONS • Sentinel Eliminator TotalGuard™ filter is a vessel under pressure containing a hot fluid. In the interests of reliable long term operation, it is strongly recommended that the Sentinel Eliminator TotalGuard filter is only installed by a qualified plumber or heating engineer.
General Description GENERAL DESCRIPTION The Sentinel Eliminator TotalGuard central heating filter is designed for the effective removal of all types of debris associated with wet central heating systems. Sophisticated hydrocyclone technology is employed to remove both magnetic (such as magnetite) and non-magnetic particles with equal effectiveness.
System Design SYSTEM DESIGN The Sentinel Eliminator TotalGuard filter is suitable for use on sealed and open vented wet central heating systems with 22mm pipework only. Please do not attempt to install on a 28mm system: the cyclones are not optimised for the flow rates normally associated with these larger systems.
Ensure heating system is turned off and drained. Step 2: Boiler Position filter on return pipe close to boiler, as per Figure 3. Fig. 3 Page 9 Page 9 Eliminator TotalGuard Installation Manual V2 01/16 Eliminator TotalGuard Instructions (26-01-16).indd 9 26/01/2016 16:39...
Page 10
Re-tighten the collar by hand, checking the flow direction on the T-piece, as per Figure 5. Page 10 Eliminator TotalGuard Installation Manual V2 01/16 Eliminator TotalGuard Instructions (26-01-16).indd 10 26/01/2016 16:39...
Page 11
Sentinel X500 Inhibited Antifreeze (whichever is appropriate for the Fig. 6 property in question). Correct levels of inhibitor can be checked with a Sentinel X100 Quick Test Kit. Page 11 Eliminator TotalGuard Installation Manual V2 01/16 Eliminator TotalGuard Instructions (26-01-16).indd 11 26/01/2016 16:40...
Dosing DOSING It is possible to use the Sentinel Eliminator TotalGuard filter as a chemical dosing point for Sentinel’s Rapid Dose products following the sequence below: Step 1: Assemble dosing adaptor in line with the Rapid-Dose instructions (for use with bleed pin).
Isolation Valving 22mm ball valve, compression fit GUARANTEE REGISTRATION Please complete and return the form opposite to Sentinel to register for your 5 year guarantee. Alternatively, you can register online at http://www.sentinelprotects.com/uk/guarantee-registration and select Eliminator TotalGuard. Full Terms and Conditions can also be found on the website.
Address Postcode Telephone Email Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on products, services and promotions in the future. If you would like to receive communications please tick here – via Post Email...
Page 16
CUSTOMER SERVICES For expert advice, any more information about the Sentinel Eliminator TotalGuard or any other product in the range please contact customer services at: Sentinel Performance Solutions Ltd. 7650 Daresbury Park Warrington Cheshire WA4 4BS Tel +44 (0) 1928 704 330 www.sentinelprotects.com...