Eliminator Nano Installation Manual Central Heating Filter Version 1 – July 2014 IMPORTANT Please retain these instructions for reference during servicing Page 1...
Safety Considerations SAFETY CONSIDERATIONS • Sentinel Eliminator Nano® filter is a pressure vessel containing a hot fluid. In the interests of reliable long term operation, it is strongly recommended that the Sentinel Eliminator Nano filter is only installed by a qualified plumber or heating engineer.
General Description GENERAL DESCRIPTION The Sentinel Eliminator Nano central heating filter is designed for the effective removal of all types of debris associated with wet central heating systems. Sophisticated hydrocyclone technology is employed to remove both magnetic (such as magnetite) and non-magnetic particles with equal effectiveness.
The main elements of the filter are shown below in Figure 1. A separate isolation valve is also supplied (see later section ‘Installation’ for further details). Bleed valve Dual seals Directional T piece Collar Collection bin Anti-tamper drain valve Fig. 1: Filter components Page 6 Eliminator Nano Installation Manual V1 07/14...
System Design SYSTEM DESIGN The Sentinel Eliminator Nano filter is suitable for use on sealed and open vented wet central heating systems with 22mm pipework only. Please do not attempt to install on a 28mm system: the cyclones are not optimised for the flow rates normally associated with these larger systems.
Regardless of pipe work orientation, the filter must be mounted vertically. Also please ensure that the flow direction of the T piece is observed. Rotate T piece to suit pipework Check ow direction Mount lter vertically Fig. 2: Vertical or horizontal pipe Page 8 Eliminator Nano Installation Manual V1 07/14...
Alternatively, the filter can be fitted Isolation valve without the supplied valve but full (supplied) isolation will not be possible, should the filter ever subsequently need to be removed. Fig. 3: Valve configuration Page 9 Page 9 Eliminator Nano Installation Manual V1 07/14...
Page 10
Any such misuse will invalidate the warranty. Page 10 Eliminator Nano Installation Manual V1 07/14...
Page 11
Sentinel X100 Inhibitor or Sentinel X500 Inhibited Antifreeze (whichever is appropriate for the property in question). Correct levels of inhibitor can be checked with a Sentinel X100 Quick Test Kit. Page 11 Eliminator Nano Installation Manual V1 07/14...
Close the valve and replace handle, together with small retaining nut. Step 5: Fig. 6 If necessary, re-pressurise the system, topping up with Sentinel X100 Inhibitor (as required). Check carefully for any leaks. Page 12 Eliminator Nano Installation Manual V1 07/14...
Dosing DOSING In instances where full isolation of the filter is achievable (as per Figure 3) it is possible to use the filter as a chemical dosing point for Sentinel’s Rapid Dose products following the sequence below: Step 1: Assemble dosing adaptor in line with the Rapid-Dose instructions (for use with bleed pin).
Please complete and return the form opposite to Sentinel to register for your 2 year guarantee. Alternatively, you can register online at http://www.sentinelprotects.com/uk/guarantee-registration and select Eliminator Nano. Full Terms and Conditions can also be found on the website. Page 14...
Address Postcode Telephone Email Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on products, services and promotions in the future. If you would like to receive communications please tick here – via Post Email...
Page 16
CUSTOMER SERVICES For expert advice, any more information about the Sentinel Eliminator Nano or any other product in the range please contact customer services at: Sentinel Performance Solutions Ltd. 7650 Daresbury Park Warrington Cheshire WA4 4BS Tel +44 (0) 1928 704 330 www.sentinelprotects.com...
Need help?
Do you have a question about the Eliminator Nano and is the answer not in the manual?
Questions and answers