Sentinel Eliminator Nano Installation Manual

Central heating filter

Advertisement

Eliminator Nano

Installation Manual

Central Heating Filter
Version 1 – July 2014
IMPORTANT
Please retain these instructions
for reference during servicing
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eliminator Nano and is the answer not in the manual?

Questions and answers

Summary of Contents for Sentinel Eliminator Nano

  • Page 1: Installation Manual

    Eliminator Nano Installation Manual Central Heating Filter Version 1 – July 2014 IMPORTANT Please retain these instructions for reference during servicing Page 1...
  • Page 2 Page 2 Eliminator Nano Installation Manual V1 07/14...
  • Page 3: Table Of Contents

    Index Section Page Safety Considerations General Description Schematic Diagram System Design Mounting Considerations Installation Procedure 9–11 Servicing Dosing Technical Specification Guarantee Please visit www.sentinelprotects.com/uk/guarantee-registration for Guarantee Registration and Terms and Conditions. Page 3 Eliminator Nano Installation Manual V1 07/14...
  • Page 4: Safety Considerations

    Safety Considerations SAFETY CONSIDERATIONS • Sentinel Eliminator Nano® filter is a pressure vessel containing a hot fluid. In the interests of reliable long term operation, it is strongly recommended that the Sentinel Eliminator Nano filter is only installed by a qualified plumber or heating engineer.
  • Page 5: General Description

    General Description GENERAL DESCRIPTION The Sentinel Eliminator Nano central heating filter is designed for the effective removal of all types of debris associated with wet central heating systems. Sophisticated hydrocyclone technology is employed to remove both magnetic (such as magnetite) and non-magnetic particles with equal effectiveness.
  • Page 6: Schematic Diagram

    The main elements of the filter are shown below in Figure 1. A separate isolation valve is also supplied (see later section ‘Installation’ for further details). Bleed valve Dual seals Directional T piece Collar Collection bin Anti-tamper drain valve Fig. 1: Filter components Page 6 Eliminator Nano Installation Manual V1 07/14...
  • Page 7: System Design

    System Design SYSTEM DESIGN The Sentinel Eliminator Nano filter is suitable for use on sealed and open vented wet central heating systems with 22mm pipework only. Please do not attempt to install on a 28mm system: the cyclones are not optimised for the flow rates normally associated with these larger systems.
  • Page 8: Mounting Considerations

    Regardless of pipe work orientation, the filter must be mounted vertically. Also please ensure that the flow direction of the T piece is observed. Rotate T piece to suit pipework Check ow direction Mount lter vertically Fig. 2: Vertical or horizontal pipe Page 8 Eliminator Nano Installation Manual V1 07/14...
  • Page 9: Installation Procedure

    Alternatively, the filter can be fitted Isolation valve without the supplied valve but full (supplied) isolation will not be possible, should the filter ever subsequently need to be removed. Fig. 3: Valve configuration Page 9 Page 9 Eliminator Nano Installation Manual V1 07/14...
  • Page 10 Any such misuse will invalidate the warranty. Page 10 Eliminator Nano Installation Manual V1 07/14...
  • Page 11 Sentinel X100 Inhibitor or Sentinel X500 Inhibited Antifreeze (whichever is appropriate for the property in question). Correct levels of inhibitor can be checked with a Sentinel X100 Quick Test Kit. Page 11 Eliminator Nano Installation Manual V1 07/14...
  • Page 12: Servicing

    Close the valve and replace handle, together with small retaining nut. Step 5: Fig. 6 If necessary, re-pressurise the system, topping up with Sentinel X100 Inhibitor (as required). Check carefully for any leaks. Page 12 Eliminator Nano Installation Manual V1 07/14...
  • Page 13: Dosing

    Dosing DOSING In instances where full isolation of the filter is achievable (as per Figure 3) it is possible to use the filter as a chemical dosing point for Sentinel’s Rapid Dose products following the sequence below: Step 1: Assemble dosing adaptor in line with the Rapid-Dose instructions (for use with bleed pin).
  • Page 14: Technical Specification

    Please complete and return the form opposite to Sentinel to register for your 2 year guarantee. Alternatively, you can register online at http://www.sentinelprotects.com/uk/guarantee-registration and select Eliminator Nano. Full Terms and Conditions can also be found on the website. Page 14...
  • Page 15: Guarantee

    Address Postcode Telephone Email Sentinel Performance Solutions Ltd and its sister companies may wish to send you information on products, services and promotions in the future. If you would like to receive communications please tick here – via Post Email...
  • Page 16 CUSTOMER SERVICES For expert advice, any more information about the Sentinel Eliminator Nano or any other product in the range please contact customer services at: Sentinel Performance Solutions Ltd. 7650 Daresbury Park Warrington Cheshire WA4 4BS Tel +44 (0) 1928 704 330 www.sentinelprotects.com...