4.3

GENIUS A / B/ PANIC

With the IO module/IO module smart, the GENIUS A
/B/ PANIC can be extended by the following inputs and
outputs:
• function.allocation.of.the.outputs:
– feedback in case of door closed and locked
– feedback in case of door open/closed
– feedback.in.case.of.active.error
– feedback in case of voltage on
– feedback in case of latch drawn
• Function.allocation.of.the.inputs:
– open
– opening impulse
– switchover day/night mode
– combination.day/night.mode./opening.via.im-
pulse control
– Silent mode
4.4

A-opener

With the IO module/IO module smart, the A-opener
can be extended by the following inputs and outputs:
• function.allocation.of.the.outputs:
– feedback.in.case.of.active.error
– feedback in case of "voltage on"
– opening.query.to.the.A-opener
• Function.allocation.of.the.inputs:
– open
– opening impulse
H39.ELEKS010EN-00