• The IO module/IO module smart and its connected Producer and service electromechanical components must not be tam- KFV Karl Fliether GmbH & Co. KG pered.with.and/or.modified. A company of the SIEGENIA GROUP Maintenance and service notes Siemensstraße 10...
Assembly instructions SIEGENIA access control systems IO module/IO module smart Other types of indicators The warning notes are set up according to the following principle: Below.is.a.list.of.symbols.used.in.these.instructions.and. their meanings: SIGNAL WORD • Items of text following this marker are found in lists. Type and source of danger –...
SIEGENIA access control systems IO module/IO module smart Functions Warning notes DANGER IO module • Function.upgrading.of.the.electromechanical.KFV. Risk of fatal injury from electric shock multi-point.locks.(slave.function) Exposed electrical components • Control of third-party drives e. g. garage door drives (master.function).in.combination.with.the.SIEGENIA. • All work on a 230 V mains power supply may only be access.control.systems.(abbreviation:.SIEGENIA.ACS)
Assembly instructions SIEGENIA access control systems IO module/IO module smart GENIUS A / B/ PANIC With the IO module/IO module smart, the GENIUS A /B/ PANIC can be extended by the following inputs and outputs: • function.allocation.of.the.outputs: – feedback in case of door closed and locked –...
Protection class IP20 Operating temperature range 0° C to 45° C Switching current output max. < 1000 mA Switching voltage output 24 V DC Overview of the electromechanical KFV drives For.every.electromechanical.KFV.drive.from.version.2.2,.integration.of.the.IO.module/IO.module.smart.via.this.is. possible..The.analogue.interface.can.also.continue.to.be.used.unrestrictedly. A-opener GENIUS A GENIUS B SI-BUS Analogue SI-BUS...
Assembly instructions SIEGENIA access control systems IO module/IO module smart Dimensions, connections and operating elements IO module/IO module smart 31.5 48.4 71.8 79.7 Item Name 12-pin.connection.terminal.strip.for.inputs.and.outputs.24.V.DC Status LED Menu LED WIFI LED (only for IO WIFI module) Connection.sockets.for.SI-BUS.connection Menu.navigation.button 12-pin connection terminal strip Connection for Function 1 / 2...
Assembly instructions SIEGENIA access control systems IO module/IO module smart Termination f For.the.termination.of.the. SI-BUS system, insert the JST termination.plug.[1].included.in. the delivery into a free SI-Bus bushing. Installation The.IO.module.is.suitable.both.for.flush-mounting.and.surface-mounting. f Break.off.the.two.brackets.for. flush-mounting. f Mount the module in a flush-mounting.box. f Use the two brackets for surface mounting.
Max. 3 SIEGENIA ACS and up to 7 IO modules can be integrated into a BUS system. The last slave component must terminate.the.SI-BUS.system.via.a.termination.plug.(included.in.delivery).or.via.a.connected.top-hat.rail.power. supply. IO module/IO module smart with frame-integrated power supply Item Name Electromechanical KFV drive (A-opener, GENIUS A, GENIUS B, GENIUS PANIC) Cable transfer Frame-integrated power supply IO.module/IO.module.smart.(termination.via.JST.plug) Inputs/outputs for external devices (e. g. intercom system) H39.ELEKS010EN-00 05.2020...
Page 12
IO module/IO module smart IO module/IO module smart with top-hat rail power supply Item Name Electromechanical KFV drive (A-opener, GENIUS A, GENIUS B, GENIUS PANIC) Cable transfer Top-hat.rail.power.supply.(termination.via.cable) IO module/IO module smart Inputs/outputs for external devices (e. g. intercom system) 12/24 05.2020...
Assembly instructions SIEGENIA access control systems IO module/IO module smart Plug-and-play cable routing with frame-integrated power supply 9.2.1 Connect KFV drive to cable transition f Insert.the.green.PTR.plug.[1]. of the adapter cable into the connection.of.the.(A-opener/ GENIUS) drive with the marking "SI-BUS" (A to D).
Assembly instructions SIEGENIA access control systems IO module/IO module smart 9.2.2 Connect cable transition to frame-integrated power supply f Attach.the.bushing.[1].of.the. adapter cable of the power sup- ply.to.the.plug.[2].of.the.cable. transition. f Insert.the.green.PTR.plug.[3].of. the adapter cable into the con- nection.„GENIUS/A-opener.side“. (0.to.3).of.the.power.supply.[4]. 9.2.3 Connect frame-integrated power supply to IO module/IO module smart f Insert.the.green.PTR.plug.[1].
Assembly instructions SIEGENIA access control systems IO module/IO module smart Plug-and-play cable routing with top-hat rail power supply 9.3.1 Connect KFV drive to cable transition f Insert.the.green.PTR.plug.[1]. of the adapter cable into the connection.of.the.(A-opener/ GENIUS) drive with the marking "SI-BUS" (A to D).
Assembly instructions SIEGENIA access control systems IO module/IO module smart 9.3.2 Connect cable transition to IO module/IO module smart f Connect.the.bushing.[1].of.the. adapter.cable.to.the.plug.[2].of. the.cable.transition. f Connect.the.bushing.[3].of.the. adapter cable to the SI-BUS con- nection.[4].of.the.IO.module/IO. module smart. 9.3.3 Connect IO module/IO module smart to top-hat rail power supply f Connect.the.bushing.[1].of.the.
Assembly instructions SIEGENIA access control systems IO module/IO module smart IO module/IO module smart in master mode 9.4.1 In combination with SIEGENIA ACS The IO module/IO module smart communicates digitally via the SI-BUS log with the SIEGENIA ACS. The IO module takes.over.the.master.function..Up.to.3.slave.components.(SIEGENIA.ACS).can.be.operated.in.a.BUS.system..The.
Assembly instructions SIEGENIA access control systems IO module/IO module smart 9.4.2 In stand-alone mode The.IO.module.is.also.designed.for.stand-alone.mode.and.can.therefore.be.operated.without.an.additional. SIEGENIA ACS. IO module smart and top-hat rail power supply via 12-pin connection IO module smart and top-hat rail power supply via SI-BUS terminal strip V V V V V V V V V.ADJ...
Assembly instructions SIEGENIA access control systems IO module/IO module smart Coupling IO module/IO module smart with A-opener/GENIUS Both.devices.must.be.coupled.to.use.the.IO.module/IO.module.smart.in.conjunction.with.an.A-opener.or.a.GENI- Detailed.information.on.operation.of. A B C D 2 3 4 the menu on the A-opener / GENIUS can.be.found.in.the.operating.instruc- tions. f For the A-opener, press the menu.button.briefly,.or.for.the.
Assembly instructions SIEGENIA access control systems IO module/IO module smart f Hold.down.the.menu.button. A B C D 2 3 4 again for approx 3 seconds to carry out the coupling. IO module f An.acoustic.signal.on.the.drive. 8x ♪ sounds as acknowledgement. f The green status LED of the module.flashes.and.an.acoustic.
Assembly instructions SIEGENIA access control systems IO module/IO module smart f Hold.down.the.menu.button. again for approx 3 seconds to carry out the coupling. f An.acoustic.signal.sounds.as. 10x ♪ acknowledgement. f An.intermittent.acoustic.signal. (10x ♪) is audible on the access control system and green is displayed.
EN 301 489-17 V2.2.1 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 61000-6-1:2007 EN 61000-6-2:2005 (Part) EN 61000-6-3:2007+A1:2011 2014/35/EU.Low.Voltage.Directive DIN EN 60730-1:2012-10 2011/65/EU RoHs This.declaration.is.responsible.for.the.manufacturers./.importers.based.in.the.European.Union.submitted.by: KFV Karl Fliether Gmbh & Co. KG Siemensstr. 10 Velbert, 2020-03-03 Uwe Ziewers 42551 Velbert, Germany (Site Manager) 22/24 05.2020 H39.ELEKS010EN-00...