Installation and start-up

Installation and start-up
The following two variants are possible for operating the CO alarm:
Wall installation
Take the following steps in the specified order to install the alarm on the wall:
1.
80 mm
2.
5 mm
Make sure not to damage any cables!
Keep CO alarm away from getting plaster dust when you drill the holes!
3.
Desk-stand
"At breathing level" in bedrooms and living rooms without combustion devices
during operation.
1. Use the two feet to place the alarm on the bottom side of the housing on a flat,
dust-free base.
Use a water level to mark the drill
holes in the horizontal position
(Spacing 80 mm).
Drill the holes with a suitable
Ø
power drill at the previously
marked locations. (Ø 5 mm)
Press the plastic dowels into the
drill holes and screw in the two
supplied screws until the screw
heads stick out approx. 5 mm.
– 30 –
2. Make sure that the alarm is standing securely and no objects prevent CO from
entering the alarm.
Start-up
1. Insert the supplied batteries into the battery compartment with the correct
polarity. The warning tone sounds, the display shows the numbers from 000 to 999
and all three LEDs flash alternately. At the end of the warm-up phase, the LEDs and
display go out.
2. The green LED flashes every 30 seconds - the CO alarm is ready for operation.
3. Then enter the current date (date of installation) on the rear label of the alarm
with a water- and smudge-proof pen (see figure):
4.
Testing the device electronics
Check the function of the CO alarm by pressing the test button for 5 seconds. To
protect your hearing, keep away from the device!
The alarm sounds four times and the red LED (alarm light) flashes four times.
This does not signalise that CO is present in the room; it is a confirmation that the
alarm is functioning properly.
Test the alarm function after installation and after every battery change without fail
(wait about 30 seconds after establishing the battery contact). A regular weekly test
is also recommended.
Installation and start-up
(e.g. 30.08.2019)
For wall installation: set the alarm
on the screws with the rear side of
the device facing downwards and
lock it into place.