1.0 SAFETY INFORMATION

The provision of the electrical supply and the connection of the unit to the mains must be
carried out by a qualified electrician.
Isolate from power supply before removing any covers. During installation / maintenance ensure
all covers are fitted before switching on the mains supply.
All-pole disconnection from the mains as shown in the wiring diagram must be incorporated
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with
latest edition of the wiring regulations.
Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct
runs terminating close to the fan must be adequately protected by suitable guards.
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of
gas or other fuel-burning appliances.
This appliance should not be used by children or persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the safe use of the appliance by a person responsible for their safety.
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried
out by children.

1.1 Hazard Symbols

GENERAL WARNING
Signifies a general warning regarding hazard specified by supplementary information.
ELECTRIC SHOCK
This unit must be completely electrically isolated before any panels are removed. Check
mains supply and control connections.
ROTATING PARTS
This unit contains fast moving rotational parts which may start automatically. It is the
sole responsibility of the installer to adequately guard these components.
REFER TO INSTRUCTION MANUAL
Read and understand the installation and maintenance manual before installing,
operating or maintaining this product.
Nuaire |
Western Industrial Estate
NA
12V & 230V Slimline Axial Fans
Installation Manual
|
|
| nuaire.co.uk
Caerphilly
CF83 1NA
IPX4
29. 10. 20. Document Number 671420
EMC Directive
2014/30/EU
LVD Directive
2014/35/EU
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NA Series and is the answer not in the manual?

Questions and answers

Summary of Contents for NuAire NA Series

  • Page 1 REFER TO INSTRUCTION MANUAL Read and understand the installation and maintenance manual before installing, operating or maintaining this product. Nuaire | | nuaire.co.uk 29. 10. 20. Document Number 671420 Western Industrial Estate...
  • Page 2 •Reusable Half Mask Respirators - when replacing filters which have been in contact with normal room or environmental air. Nuaire would always recommend a site specific risk assessment by a competent person to determine if any additional PPE is required.
  • Page 3 (3 amp) spur incorporating a double or triple pole switch with contact openings of at least 3mm. Use twin conductor cable of at least 1mm in section (Figure 9). Nuaire | | nuaire.co.uk 29. 10. 20. Document Number 671420 Western Industrial Estate...
  • Page 4 4.2.3 NA 100T/100HT/150T/150HT with Light / Remote Switch 230V 230V Wiring - NA 100T/100HT/150T/150HT 50Hz 230V 50Hz Triple Pole Isolator Fan unit Triple Pole Isolator Nuaire | | nuaire.co.uk 29. 10. 20. Document Number 671420 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 5 Please call After Sales Support for further information on items not listed above. Ensure that Nuaire product is made safe from any electrical / water / refrigerant supplies before dismantling commences. This work should only be undertaken by a qualified person in accordance with local authority regulations and guidelines, taking into account all site based risks.
  • Page 6 Installation Manual NOTES Nuaire | | nuaire.co.uk 29. 10. 20. Document Number 671420 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 7 Installation Manual NOTES Nuaire | | nuaire.co.uk 29. 10. 20. Document Number 671420 Western Industrial Estate Caerphilly CF83 1NA...
  • Page 8 Installation Manual NOTES Nuaire | | nuaire.co.uk 29. 10. 20. Document Number 671420 Western Industrial Estate Caerphilly CF83 1NA...

This manual is also suitable for:

Na100Na100pcNa100tNa100htNa100pirNa100-12 ... Show all

Table of Contents