    International Electronics, Inc. 427 Turnpike Street Canton, Massachusetts 02021 SSiLW ( ILLUMINATED WEATHER RESISTANT) Installation Manual Features: Vandal resistant metal case Illuminated Backlit Hardened Keys Heavy Traffic Application Flush Mount Indoor / outdoor Applications Fully encapsulated Installation: Section 1: Unpacking and checking the packing list. Section 2: Mounting the SSiLW.
  • Page 3: Section 2: Mounting The Ssilw ( 212-Sil & 232-Sil)

    Section 2: Mounting the SSiLW ( 212-SiL & 232-SiL) 1. Select the appropriate location for the SSiLW. Mounting height is the same for an electrical switch, 48" on center. The SSiLW should be mounted to a standard single gang electrical box (with the small slot in the trim ring facing down), but it also is able to mount directly to a flat surface with the provided mounting screws.
  • Page 4 Wiring the SSiLW to a Wiegand panel Electrical Insulator Electrical Wiegand control Tape Panel. Tape LED 1 -GND +5 – 12 vdc Color to color Red = Positive Keypad Black = Negative White / Black = Data 0 White / Yellow = Data 1 Drain wire Blue = Led 1 Brown = Not used...
  • Page 5 Integrated access control using an electromagnetic lock Forced door & Door ajar functions require a normally closed set of door contacts Siren To alarm panel Closed loop Sounder Normally closed Normally door contacts Open switch Part # EZ REX NO C NC NO C NC NO C NC 12 –...
  • Page 6 Basic access control using an electric door strike Normally closed Door contacts Normally Open switch Forced door & Door ajar functions require a normally closed set of door contacts Part # EZ REX NO C NC NO C NC NO C NC Input loop common = WO Door position input = W 12 –...
  • Page 7 Integrated access control with an electric door strike Forced door & Door ajar functions require a normally closed set of door contacts Siren To alarm panel Closed loop Sounder Normally Open switch Normally closed door contacts Part # EZ REX NO C NC NO C NC NO C NC 12 –...
  • Page 8: Section: 4 Programming

    Section: 4 Programming SSiLW Program Options Chart If the pre-programmed default values must be changed, Or additional functions are desired, the following options may be programmed. To Enter SSiLW Keypad program mode: 099 # “program code” The keypads yellow LED will flash twice rapidly indicating that you are in program mode.
  • Page 9: Wiegand Formats

    Wiegand formats If there is need to change your Wiegand format from 26 bit , use the chart below 92 # Options # Value # * * 1. –Wiegand format 1 – 8 ( Defaults to 1 = 26 Bit ) 2.
  • Page 10: Troubleshooting

    Trouble shooting Section 6: Trouble Shooting. Refer to this section if the SSiLW is not responding correctly to the operation outlined in this instruction manual. The SSiLW has been designed to operate with 5 - 12 VDC only. Verify that the voltage powering this keypad is within these parameters.
  • Page 11 Defaulting the SSiLW keypad If the four data wires are shorted in one of the two configurations shown below on power up, the option will be set. Remove power after you hear the 3 beeps then reconnect the data lines to their proper working configuration.
  • Page 12 International Electronics Incorporated (IEI) warrants its products to be free from defects in material and workmanship, when they have been installed in accordance with the manufacturer’s instructions, and have not been modified or tampered with. IEI does not assume any responsibility for damage or injury to person or property due to improper care, storage handling, abuse, misuse, normal wear and tear, or an act of God.
  • Page 13 Weep holes Note: Use this template to help d rill holes for easy installation www.ieib.com Page 13 of 13 6050723 Rev 1.0...