Cewe CQ Installation Instructions Manual

Panel instruments for measuring of d.c current, d.c voltage, a.c current, a.c voltage, power, powerfactor an frequency

Advertisement

Available languages

Available languages

Quick Links

Visarinstrument/ Panel Instrument
Installationsanvisning / Installation instruction
Innehåll
Installationsanvisning Utf. 1 ....... 2
Installationsanvisning Utf. 2 ....... 3
Anmärkningar ............................ 6
Contents
Installation instruction Model 1 ....4
Installation instruction Model 2 .... 5
Comments .... .............................. 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Cewe CQ

  • Page 1 Visarinstrument/ Panel Instrument Installationsanvisning / Installation instruction Innehåll Contents Installationsanvisning Utf. 1 ..2 Installation instruction Model 1 ..4 Installationsanvisning Utf. 2 ..3 Installation instruction Model 2 ..5 Anmärkningar ......6 Comments ........6...
  • Page 2 + och –. Var noga med att ansluta rätt ström, växelspänning, effekt, effektfaktor och frekvens. polaritet till instrumentet. Typbeteckning: CQ, IQ, CL, CQR, CLR, QB, IQB, PQ, PL, Instrumenten för mätning av effekt/effektfaktor har inkopp- QQ, QL, PFQ, PFL, FQ, FL lingsschema på...
  • Page 3 + och –. Var noga med att ansluta rätt ström, växelspänning, effekt, effektfaktor och frekvens. polaritet till instrumentet. Typbeteckning: CQ, IQ, CL, CQR, CLR, QB, IQB, PQ, PL, Instrumenten för mätning av effekt/effektfaktor har inkopp- QQ, QL, PFQ, PFL, FQ, FL lingsschema på...
  • Page 4 + and -. Make sure that the correct polarity is A.C current, A.C voltage, power, powerfactor and frequency. connected to the instrument. Types: CQ, IQ, CL, CQR, CLR, QB, IQB, PQ, PL, QQ, QL, Instruments for measuring power/powerfactor are labelled with PFQ, PFL, FQ, FL connection drawings.
  • Page 5 + and -. Make sure that the correct polarity is connec- A.C current, A.C voltage, power, powerfactor and frequency. ted to the instrument. Types: CQ, IQ, CL, CQR, CLR, QB, IQB, PQ, PL, QQ, QL, Instruments for measuring power/powerfactor are labelled with PFQ, PFL, FQ, FL connection drawings.
  • Page 6 Anmärkning A: Comment A: Om instrumentets omgivningsförhållanden är annorlunda än If the instrument is used in ambient conditions other than speci- vad som anges i denna manual, kan noggrannhet och livslängd fied in this manual, the accuracy and lifetime may be degraded. påverkas.
  • Page 8 Secure Meters (Sweden) AB Box 1006 • SE-611 29 Nyköping • SWEDEN Tel: +46 155 775 00 • Fax: +46 155 775 96 e-mail: sales_europe@securemeters.com • www.cewesecure.se A0030se-14...

This manual is also suitable for:

CqrClClrQbIqbFq ... Show all

Table of Contents