Regulator - SA106R
Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar)
Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . . .88cfm
Ports-inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BsP
outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4"BsP
Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/8"BsP
4. ASSEMBLY
4.1.
confirm that all items are present and undamaged. if any parts are missing or damaged please contact the supplier.
SA106 - combined filter, regulator with gauge, lubricator and mounting bracket.
SA106FR - combined filter, regulator with gauge and mounting bracket.
SA106F - filter.
SA106L - lubricator.
SA106R - regulator with gauge and mounting bracket.
4.2.
fig.1 shows a typical air line installation. the filter is located
upstream of the regulator - unless combined, as in sA106 and
sA106fr - and the lubricator downstream.
4.3.
filter/regulator - install using the mounting bracket provided.
Before connecting system piping ensure that gauge is visible,
unused gauge port is sealed with plug provided and that flow
direction arrow matches system air flow.
4.4.
filter and lubricator - install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that
flow arrows are correct and that filter is upstream and lubricator downstream of regulator.
Note: to ensure air-tight joints, use Ptfe tape.
5. OpERATION
5.1.
Regulator - the output pressure is controlled by the knob. Before pressurising the air system for the first time, pull out and rotate the
knob anticlockwise to remove any loading on the regulator spring. Pressurise the system and then rotate knob clockwise to set required
output pressure, as shown on gauge. When the required pressure is achieved push in knob to prevent inadvertent adjustment.
Note: for correct pressure setting always adjust up from a lower pressure. therefore to reset from 90 to 70psi for example, reduce
pressure from 90 to 60psi and then increase to 70psi.
5.2.
Filter - the bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down the drain valve at the bottom of the
bowl, allow to drain and then release. drain valve has female 1/8" BsP outlet.
5.3.
Lubricator - remove the filler plug (fig.2.A) and fill bowl up to max. level, with air tool oil. this can be done with the air line pressurised.
With air flowing through the lubricator the oil delivery rate can be adjusted by screw (fig.2.C) whilst watching the drip rate through the
sight dome (fig.2.B). the oil delivery rate will automatically increase or decrease in line with the air flow.
5.4.
Both the filter and the lubricator are supplied with a metal bowl guard. to remove the guard, pull down the latch (fig.3.D) and rotate
the guard until either of the two pairs of lines (fig.3.E) on the guard align with the similar marks (fig.3.F) on the head. the guard
can now be removed. to refit, slide the top of the guard into the head with the guard and head markings aligned, and then rotate the
guard so that the latch aligns with the marks on the head. the latch will lock into place.
fig.2
© Jack sealey limited
WARNING! Filter and lubricator bowls are manufactured
from polycarbonate and must not be used at temperatures
over 125°F (52°C) or for pressures over 218psi (15 bar).
polycarbonate can be damaged and may fail if exposed to
certain solvents either internally or externally - strong
alkalies, compressor oils containing aromatic hydrocarbons
or fire retardant oils, or the fumes of any of these.
Clean with warm water only.