MARKS USA iQ Wik Data Series Quick Set-Up Programming Manual

Advertisement

Quick Set-Up Programming Guide For
STEP 1 - INITIALIZE LOCK ID:
NOTE: The Lock ID is a six digit number of your choosing. Skipping this step will default the Lock ID to 000001.
At the keypad, Enter the Factory Code: 9991234, then the # key, enter 6 Digit Lock ID, then the # key.
EXAMPLE
The Lock ID will NOT open the lock.
STEP 2 - CREATE GREAT GRAND MASTER (GGM):
Your GGM will consist of a User ID (UID) and a Personal Identification Number (PIN). You should have these
numbers established before you begin to program the lock. This code is required by the SYSTEM MANAGER to
perform all programming functions.
NOTE: UID can be 2, 3 or 4 digits in length. PIN can be 3, 4, 5 or 6 digits in length.
At the keypad, Enter the Factory Code: 9991234, then the
EXAMPLE
The GGM is now established for the SYSTEM MANAGER.
LOCK IS NOW INITIALIZED!
STEP 3 - TEST LOCK:
At the keypad enter UID, PIN, then the
EXAMPLE
After entering this code the LED will turn green and lock will allow access for 3 seconds.
Marks USA • www.marksusa.com • 631-225-5400 • 800-526-0233 • Fax: 631-225-6136 • © 2009, Marks USA
Factory Code
9991234
9991234
key.
UID
365 Bayview Ave., Amityville, NY 11701
631-225-5400 • 1-800-526-0233 • Fax 631-225-6136 • www.marksusa.com
&
#
6 digit Lock ID
#
000001
key, enter UID, then the # key, enter PIN, then the # key.
UID #
PIN
Series Locksets
#
#
PIN #
IQ101G 03.09

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iQ Wik Data Series and is the answer not in the manual?

Questions and answers

Summary of Contents for MARKS USA iQ Wik Data Series

  • Page 1 At the keypad enter UID, PIN, then the key.  EXAMPLE  After entering this code the LED will turn green and lock will allow access for 3 seconds. Marks USA • www.marksusa.com • 631-225-5400 • 800-526-0233 • Fax: 631-225-6136 • © 2009, Marks USA IQ101G 03.09...
  • Page 2 LED INDICATING RED (PROGRAMMING MODE) 1. Denotes incorrect entry or error and vacates programming mode. 2. Programming mode vacated if no key entry within 5 seconds Marks USA • www.marksusa.com • 631-225-5400 • 800-526-0233 • Fax: 631-225-6136 • © 2009, Marks USA IQ101G 03.09...

This manual is also suitable for:

Iq wik prox series

Table of Contents