MANU.400S.QUICKSTART Rev.5 date 20/03/09 INVER INVER TER SERIES 400 TER SERIES 400 INVER TER SERIES 400 TER SERIES 400 INVER INVER TER SERIES 400 G-SERIES G-SERIES G-SERIES VECT VECT VECT ORIAL MO VECT ORIAL MO ORIAL MO ORIAL MO T T T T T ORS G-SERIES G-SERIES VECT...
PAGE INDEX Via Ugo Foscolo, 20 2 / 48 36030 - CALDOGNO - VICENZA - ITALY Chapter 1: GENERAL WARNINGS BEFORE INSTALLATION ............. pag. 3 - Description of symbols in the manual ....................pag. 3 - General instructions on safety ....................... pag.
Diagrams are mere examples and should be perfected by the customer. - The product warranty is considered ex-works and is valid 12 months from the date of leaving ROWAN ELETTRONICA s.r.l. premises, according to the conditions written on the specific document to be asked ROWAN Sales Department.
Thanks to serial connection, the keyboard can be distanced from the panel of a control panel by a max. 25m distance. ROWAN ELETTRONICA s.r.l. supplies on request the keyboard distancing cable. Display area for the description of the...
QUICK INSTALLATION IN PAGE Chapter 3 Via Ugo Foscolo, 20 5 / 48 SCALAR MODE 36030 - CALDOGNO - VICENZA - ITALY Quick installation aims The aim of this paragraph is to teach the user, quickly and correctly, speed setup by a potentiometer of a normal asynchronous motor in V/F (Voltage/Frequency) scalar mode.
QUICK INSTALLATION IN PAGE Chapter 3 Via Ugo Foscolo, 20 SCALAR MODE 6 / 48 36030 - CALDOGNO - VICENZA - ITALY Installation in scalar mode Read carefully Chapter 1: GENERAL WARNINGS BEFORE INSTALLATION before installing. See Chapter 6: MECHANICAL INSTALLATION for the inverter positioning. See Chapter 7: ELECTRICAL INSTALLATION for connecting the inverter and for E.M.C.
QUICK INSTALLATION IN PAGE Chapter 3 Via Ugo Foscolo, 20 7 / 48 SCALAR MODE 36030 - CALDOGNO - VICENZA - ITALY MIN MOTOR SPEED Set the motor min. speed 1.3.2 0.rpm Setup range: from 0 rpm to par. 1.3.1 MAX MOTOR SPEED FIXED BOOST Set the fixed boost voltage on the motor, active from 0.0Hz to 20.0Hz 1.5.1...
QUICK INSTALLATION IN PAGE Chapter 4 Via Ugo Foscolo, 20 8 / 48 VECTORIAL MODE 36030 - CALDOGNO - VICENZA - ITALY QUICK INSTALLATION AIMS The aim of this paragraph is to teach the user, quickly and correctly, speed setup by a potentiometer of a Rowan asynchronous threephase motor in vectorial control with ring closure encoder according to the FIELD ORIENTATION mode.
QUICK INSTALLATION IN PAGE Chapter 4 Via Ugo Foscolo, 20 9 / 48 VECTORIAL MODE 36030 - CALDOGNO - VICENZA - ITALY Installation in vectorial mode Connect the inverter with ref. to the Vectorial connection diagrams on the previous page. Caution ! Before installation, check the torque characteristics table regarding the possible match between G-Series Rowan motor and the inverter in hand.
PAGE Chapter 5 TECHNICAL FEATURES Via Ugo Foscolo, 20 12 / 48 36030 - CALDOGNO - VICENZA - ITALY SUMMARY TABLE OF POWER ELECTRICAL FEATURES FOR INVERTERS SERIES 400 FROM /P TO /6 * Pmotor KW = Shaft power of a standard asynchronous motor * Pmax KVA = Max.
PAGE Chapter 5 TECHNICAL FEATURES Via Ugo Foscolo, 20 13 / 48 36030 - CALDOGNO - VICENZA - ITALY SUMMARY TABLE OF POWER ELECTRICAL FEATURES FOR INVERTERS SERIES 400 FROM /6,5 TO /F * Pmotor KW = Shaft power of a standard asynchronous motor * Pmax KVA = Max.
PAGE Chapter 6 MECHANICAL INSTALLATION Via Ugo Foscolo, 20 14 / 48 36030 - CALDOGNO - VICENZA - ITALY Dimensions and weights for inverters from 400/P to 400/L (vertical versions) Fixing holes are intended for 4MA screws All dimensions are in mm Dimensions and weights for inverters from 400/2 to 400/F (horizontal versions) Fixing holes are intended for 5MA screws All dimensions are in mm...
PAGE Chapter 6 MECHANICAL INSTALLATION Via Ugo Foscolo, 20 15 / 48 36030 - CALDOGNO - VICENZA - ITALY Suggestions for a correct mechanical installation - Make sure that the characteristics of the area in which the inverter is to be installed fall within the recommended characteristics given in Chapter 5: TECHNICAL FEATURES (temperature, humidity, protection level, altitude).
PAGE Chapter 7 ELECTRICAL INSTALLATION Via Ugo Foscolo, 20 16 / 48 36030 - CALDOGNO - VICENZA - ITALY General warnings before connection of the threephase power supply TN- (Threephase + Neutral to Ground) and TT- (Threephase + Ground) network connections Rowan inverters are designed to be powered by this kind of threephase nertworks, electrically symmetrical to Ground.
Table of threephase anti E.M.I. filters electrical features and dimensions Table of threephase anti E.M.I. filters and ferrite toroids for different inverters * NOTE: if wiring with thicker section cable is needed, Rowan Elettronica can supply suitable terminals to ease the connection, ask our Technical Dpt about this possibility.
ELECTRICAL INSTALLATION PAGE Chapter 7 ELECTRICAL INSTALLATION Via Ugo Foscolo, 20 18 / 48 36030 - CALDOGNO - VICENZA - ITALY Reducing the harmonic distortion Should be necessary to reduce the harmonic distortion, a threephase inductor can be supplied on request. This inductor should be inserted between the supply network and the EMI filter, as shown below: MOTOR M E T A L L I C...
PAGE Chapter 7 ELECTRICAL INSTALLATION Via Ugo Foscolo, 20 19 / 48 36030 - CALDOGNO - VICENZA - ITALY Reducing dV/dT ripples to the motor The voltage that supplies the motor connected to the generator is obtained using the PWM technique, which means that it is formed by a sequence of variable duration pulses.
PAGE Chapter 8 BRAKING RESISTORS Via Ugo Foscolo, 20 20 / 48 36030 - CALDOGNO - VICENZA - ITALY Table of braking resistors for Rowan inverters To have an idea, 2 typical examples of braking resistor installation and their related power features are described in the table above.
PAGE Chapter 8 BRAKING RESISTORS Via Ugo Foscolo, 20 21 / 48 36030 - CALDOGNO - VICENZA - ITALY RES.140R.600 and RES.70R.600 braking resistors dimensions ROWAN EL. CAN SUPPLY TWO DIFFERENT CONNECTION WIRES VERSIONS OF FLAT RESISTANCES FOR 11.5 EACH CODE TIPO 2 TIPO 1 Dimensions in mm...
PAGE Chapter 9 TERMINAL BOARD DESCRIPTION Via Ugo Foscolo, 20 22 / 48 36030 - CALDOGNO - VICENZA - ITALY SIGNAL TERMINAL BOARD POWER TERMINAL BOARD POWER TERMINAL BOARD VERTICAL VERSION HORIZONTAL VERSION POWER SIZES FROM /P POWER SIZES FROM /L TO /F TO /1 Earth connection Threephase asynchronous motor connection...