TROUBLESHOOTING
Symptom
Jack will not lift load
Jack will lift, but not maintain
pressure
Jack will not lower after unloading
Poor lift performance
Will not lift to full extension
For a period of one (1) year from date of purchase, SFA Companies will repair or replace, at its option,
without charge, any of its products which fails due to a defect in material or workmanship, or which fails to conform
to any implied warranty not excluded hereby.
Performance of any obligation under this warranty may be obtained by returning the warranted product,
freight prepaid, to SFA Companies Warranty Service Department, 10939 N. Pomona Ave., Kansas City, MO 64153.
Except where such limitations and exclusions are specifically prohibited by applicable law, (1) The
CONSUMER'S SOLE AND EXCLUSIVE REMEDY SHALL BE THE REPAIR OR REPLACEMENT OF DEFECTIVE
PRODUCTS AS DESCRIBED ABOVE, and (2) SFA Companies SHALL NOT BE LIABLE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGE OR LOSS WHATSOEVER, and (3) THE DURATION OF ANY AND
ALL EXPRESSED AND IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS LIMITED TO A PERIOD OF ONE (1) YEAR
FROM DATE OF PURCHASE.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not
apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
Possible Causes
•
Release valve not tightly closed
•
Overload condition
•
Air supply inadequate
•
Release valve not tightly closed
•
Overload condition
•
Hydraulic unit malfunction
•
Reservoir overfilled
•
Fluid level low
•
Air trapped in system
•
Fluid level low
ONE YEAR LIMITED WARRANTY
•
Ensure release valve tightly closed
•
Remedy overload condition
•
Ensure adequate air supply
•
Ensure release valve tightly closed
•
Remedy overload condition
•
Contact Omega Tech. Service
•
Ensure load is removed, then drain fluid
to proper level
•
Ensure proper fluid level
•
With ram fully retracted, remove oil filler
screw/plug to let pressurized air escape,
then reinstall oil filler screw/plug
•
Ensure proper fluid level
5
Corrective Action