ELECTRONIC DOUBLE CODE SAFES
Please read all of these instructions carefully before commencing using your
safe. Try all of these procedures with the door open first, until you are familiar with how the safe works
1. FEATURES
High performance microprocessor.
ALKALINE BATTERY inner feeding.
12 key membrane keyboard: 10 keys with 0 to 9 figures. 4 dedicated led and contacts for external emergency feeding in
case of exhausted inner battery.
"ON" key to activate the circuit.
"ENTER" key to confirm code set and consent to the opening.
Internal programming key for a new personal code (in some models it is protected with a sliding cover).
TWO PERSONAL OPENING CODES WHICH CAN BE SET UP.
DIGITS THAT CAN BE
combination).
2. INTRODUCTION
ALL SAFES ARE PROVIDED WITH SERVICE CODE "1 1 1 1 1 1".
THE SAFE OFFERS TWO CODE TO BE SET UP, WE ADVISE TO USE BOTH OF THEM TO AVOID
FORGETTING THEM.
Before installing the safe, check that it works properly and read the instructions carefully to understand the operation.
Every time a key is pressed the green "OK" LED lights up and the buzzer sounds; pressing the "ENTER" key causes the
green "OK" LED to light up for correct procedures, or the red "ERROR" LED to light up in the case of incorrect settings.
3. FIRST APPLICATION
 Alimentation:
Unscrew the cover screw and put the batteries, of the type stated on the label, into the proper case on the rear of the lock
(see picture 1) - Screw again the cover screw.
Use only and exclusively alkaline batteries.
 Safety block removal:
remove completely (without screwing it any longer) the blocking black screw, blocking the magnet, which is marked by a
proper yellow tag.
To screw the black screw after removing it compromises the safe operation.
 Test for opening using the service code "1 1 1 1 1 1" (with door open and bolts extended):
Press "ON", key in the service code "111111" and press "ENTER". The green "OK" LED lights up for about five
1.
seconds.
Within this time, with the green LED "ON", turn the knob clockwise to retract the bolts. If the combination is incorrect,
2.
the red "ERROR" LED will light up and the buzzer will sound. After three attempts with incorrect codes, the keyboard
will be disabled for one minute and this time will be indicated by the red "ERROR" LED flashing. After this time,
renewed readiness for operation will be indicated by the green "OK" LED lighting up and a beep
4. STORING THE PERSONAL CODE:
With the door open and the bolts outside, press the "ON" key and, after that, the "PROGRAMMING" key place on the
1.
inside side of the door ( see Picture 1). The "CODE" green LED lights up with a fixed light for about 10 seconds.
Within 10 seconds, start keying in your new personal code (min. 6 – max. 10 digits) and press "ENTER".
2.
3.
Start keying to confirm your personal code and to press the key "Enter."
If you do not want to program the second code, wait some seconds and a multiple tone signal shall confirm that
In order to store a second code, go on with following procedure at the end of item 3 within 3 seconds:
4.
Press the " PROGRAMMING Key"
5.
Start keying to second personal code from 6 to 10 figures and to press the key "Enter."
6.
Start keying to confirm your second personal code and to press the key "Enter."
A multiple tone signal shall confirm that your codes have been stored.
Istr-trony-6 cod-eng.doc
SET: minimum 6 – maximum 10. (the "ENTER" and "ON" keys are not valid in the
WARNING!
your personal code has been stored.
.
Pag. 1 di 2

Advertisement

loading

Summary of Contents for Technomax Trony Series

  • Page 1 INSTRUCTION HANDBOOK FOR ELECTRONIC DOUBLE CODE SAFES Please read all of these instructions carefully before commencing using your safe. Try all of these procedures with the door open first, until you are familiar with how the safe works 1. FEATURES ...
  • Page 2 Note: To activate/modify the second personal code you shall always program the first one again. 5. RESETTING CODES  Is possible cancel the personal codes pressing the “button PROGRAMMING” and the “ON” button for 5 sec. The first code goes on 111111 and the second code will be deactivated. Note: If errors have been made while setting your new code, this will be indicated by the red “ERROR”...