Check/adjust
astigmatism and FOCUS.
a.
Set the TIME/DIV switch to the X-Y position, and the input coupling
switch to GND.
b.
Set the INTENsity control ~or a small. spot, as the. Collowing figure,
using the position controls.
(,:? div )
Spot -
--
.
-
-
.
·1
Screen
div
c.
Check that the spot is round.
d.
Adjust the FOCUS adjustment and astig. adjustment
VR803
Cor a
round spot.
HORIZONTAL SYSTEM
!Control settings
I
Preset the controls as given in the preliminary control settings.
C:J)
Check/ adjust horizontal gain.
a.
Set the input AC-GND-DC to DC.
b.
Connect the cable to the output or the time mark generator.
c.
Set the time mark generator for
O.
Sms time mai: : ks •
d.
Check that the time marks align with the graticule lines over the
center eight divisions, within J
%.
e.
Adjust the H GAIN adjustment
VR605
so that the time marks coincide
with the middle eight graticule lines.
@;
C-heck/ adjust Horizonta. l x 1 0
M~C
Gain.
a.
Set the TIME/DIV switch to O.Sms.
b.
Set x
t
O
MAG (pull_ out the knob or the POSITION control).
c.
Check that the one-cycle time marks align with the ten-divisions
1raticule lines , within 5 ~.