541N SERIES Introduction The 541N Series are electronic 2- or 4-cycle regeneration control valves for softening of drinking and feed water supplies. When the drain solenoid is activated, the valve is automatically transferred to the regeneration position; together with the optional additional solenoid valve(s) integrated in the back cap of the control valve body, this simple and reliable system guarantees years of trouble-free service.
In case of the 541 valve, it also helps to keep the piston in the regeneration position when the operating pressure is extremely low (< 1,5 bar). Drain F.C. Tank inch Gal/min (l/min) (4,5) (4,5) (6,1) (7,6) (9,8) (13,2) Erie Water Treatment Controls – Belgium Page 5...
(with plug ø 2,5 mm x 5,5 mm) into socket at the timers power lead and plug transformer into socket; the connection can be secured by means of the wire clip. Erie Water Treatment Controls – Belgium Page 6...
2. Turn the drain flow adjuster either to the right or to the left until the piston remains stable in the regeneration position. Do note that closing the drain flow adjuster too much, will result in bad suction of the injector. Erie Water Treatment Controls – Belgium Page 8...
Page 11
541N SERIES Erie Water Treatment Controls – Belgium Page 9...
In the event of a timer failure, the display will show the message: Service Required In such case, entering one of the programming levels can possibly solve the problem. However if the problem persists, professional service is required. Erie Water Treatment Controls – Belgium Page 10...
Page 13
If the control valve is left in this position, the countdown timer will countdown to 0 sec and start a regeneration. To cancel this mode, press the scroll button before the countdown timer has reached 0 sec; the control valve will return to the service mode. Erie Water Treatment Controls – Belgium Page 11...
3. Press the scroll button again; the display will show: Set hardn.: XX°f Press the up button or down button to set the water hardness of the incoming untreated water. Erie Water Treatment Controls – Belgium Page 12...
Page 15
Press the up button or down button to set the model of flow meter used: SNAP SENSOR: model with snap-on flow meter sensor. SCREW SENSOR: model with sensor fixed by means of screw. Erie Water Treatment Controls – Belgium Page 13...
Page 16
11. Press the scroll button again; the display will show: Exit Press the up button or down button to save the program to the NOVRAM® and exit the programming level. Erie Water Treatment Controls – Belgium Page 14...
1. Disconnect the connector from the drain solenoid. 2. Disconnect the drain hose from the drain solenoid. 3. Unscrew the drain solenoid from the drain port. 4. Reverse the procedure for reassembly. Erie Water Treatment Controls – Belgium Page 16...
6. Install a new injector gasket; mind the alignment over the alignment post. 7. Install the injector; mind the alignment over the alignment post. 8. Install the injector cover plate. 9. Install the 3 injector cover plate screws and tighten them evenly. Erie Water Treatment Controls – Belgium Page 17...
2. Remove the screw and washer from the centre of the main diaphragm. 3. Remove the main diaphragm from the body stem assembly. 4. Reverse the procedure for reassembly; make sure the drain port O-ring is securely installed in the valve body groove. Erie Water Treatment Controls – Belgium Page 18...
15. Install the drain hose to the drain solenoid and the brine line to the brine elbow. 16. Install the inlet and outlet to the control valve. 17. Install the flow meter connector to the outlet elbow. Erie Water Treatment Controls – Belgium Page 19...
2. Unscrew the outlet from the outlet elbow on the control valve. 3. Unscrew the outlet elbow from the control valve. 4. Pull out the hub from the outlet elbow. 5. Remove the impeller. 6. Reverse the procedure for reassembly. Erie Water Treatment Controls – Belgium Page 20...
Page 23
541N SERIES Erie Water Treatment Controls – Belgium Page 21...
7. Verify brine line for kinks or restrictions 8. Leak in brine line 8. Verify brine line and connections for air leakage 9. Not enough water in brine tank 9. Refer to problem “Valve fails to refill brine tank” Erie Water Treatment Controls – Belgium Page 22...
Page 25
Loss of resin Cause Solution 1. Lower and/or upper distributor 1. Replace distributor(s) damaged 2. Leak between riser tube and upper 2. Verify that riser tube is seated correctly and is not cracked distributor Erie Water Treatment Controls – Belgium Page 23...
Page 26
3. Verify that distributors are free of debris 4. Crushed lower and/or upper distributor 4. Replace distributor(s) Drain flows continuously Cause Solution 1. Drain solenoid stuck in open position 1. Clean drain solenoid 2. Defective PCB 2. Replace PCB Erie Water Treatment Controls – Belgium Page 24...
4. Verify programming of timer; re-program timer if necessary. 5. Verify correct execution of program. 6. Measure the residual hardness; adjust mixing valve if necessary. 7. Verify min. and max. water pressure; install pressure reducer if necessary. Erie Water Treatment Controls – Belgium Page 25...
541N SERIES Valve body 541N18 ITEM PART NUMBER DESCRIPTION 15/91 Screw, solenoid (3x) 413/134/24 Solenoid Erie Water Treatment Controls – Belgium Page 28...
Page 31
Valve body (incl. 467/216) for mixing valve 72543 Elbow, outlet 72544 Impeller 72545 Hub, Impeller RK/413 Repair kit solenoid diaphragm RK/541/244 Repair kit body stem and seat 72611 Repair kit body stem Size: refer to “Sizing Table” Erie Water Treatment Controls – Belgium Page 29...