Status Leds - Fleet Power 2000 Owner's Manual

Xantrex technology inverter/battery chargers owner's manual
Table of Contents

Advertisement

STATUS LEDs

Status LED
INV/CHRG
(Inverter/Charg
AC Input
Steady
Overload
Blinking
Overload
Steady Battery
Blinking
Battery
10
90-0115-00
10/97 Fltman.pm65
Power on light. It will be illuminated whenever the
power switch is on (inverter on) or when there is
incoming AC power and the charger comes on.
Illuminates when incoming AC power has been
applied and the transfer relays have engaged.
There is a 7-12 second delay from the time the AC
is applied and this LED illuminates.
Indicates an over-temperature condition, the unit is
shut down. It will reset automatically after cooling.
Inverter mode- Shutdown, diagnose problem using
DC Amps bar graph. Charger mode- Thermal
shutdown, after cooling reset by cycling power
switch.
This is a High/Low Battery warning condition.
Inverter mode: Battery > 15.25 or < 10.50 volts
Charger mode: Battery > 15.25 or < 10.00 volts
Indicates either a shutdown or equalizing.
Battery > 15.50 volts, will auto-reset at 15.25.
Inverter mode: Battery < 10.00 volts, will auto reset
at charger float voltage or upon AC input.
Charger mode: Battery < 8.00 volts for 1 minute,
remove all DC loads and manually reset by cycling
the power switch.
disconnecting and reapplying shorepower.
Purpose