Wren DRS5004 Installation And Maintenance Manual

4 - 16 analog channel drs digital recording solution series
Table of Contents

Advertisement

DRS Digital Recording Solution Series
Installation and Maintenance Guide
v 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRS5004 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wren DRS5004

  • Page 1 DRS Digital Recording Solution Series Installation and Maintenance Guide v 1.1...
  • Page 2: Fcc Compliance Statement

    DRS5116 FCC Compliance Statement Caution: Any changes or modifications in construction of this device which are not approved, the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules.
  • Page 3: Important Notice

    5. Security surveillance laws may differ for each location. Therefore, please check with the local ordinances to avoid any surveillance law violations. * Be cautious not to cause electrical damage to the unit by applying DRS5004 DRS5008 * 12VDC * 12VDC * Be sure to use the DC Adaptor provided by Wren.
  • Page 4: Table Of Contents

    Table of Contents Table of Contents Overview ... 10 What is DRS Digital Recording Solution? ...10 Component List ... 11 Description & Function ...12 Installation and Connection... 18 Connecting & Running ...18 4.1. Connecting Camera ...18 4.2. Connecting Monitor ...19 4.3.
  • Page 5 Table of Contents 8.1. Viewing Image ...28 8.2. Setting Date & Time ...29 8.2.1. Time Zone...29 8.2.2. Daylight Saving ...29 8.2.3. Sync with NTP ...29 8.2.4. Time Format...30 8.2.5. Date...30 8.2.6. Time...30 8.2.7. Apply Date/Time...30 8.3. Setting Recording Condition...31 8.3.1. Configuration Status ...31 8.3.2.
  • Page 6 13.2. Rear Panel DRS5016 / 5116 Models...56 13.3. Front Panel DRS5008 Model ...57 13.4. Rear Panel DRS5008 Models ...58 13.5. Front Panel DRS5004 Series Models...59 13.6. Rear Panel DRS5004 Models ...61 13.7. Installation Summary ...61 Wren DRS5116 2003. 09. 06 (v 1.0)
  • Page 7 Table of Contents Basic Configuration ... 62 Monitoring...62 14.1. Viewing Basic Screen (Quad-Split)...62 14.2. Viewing Single Full Screen ...62 14.3. Viewing Multi Screen ...62 14.4. Viewing all Channels with Sequence Mode ...63 14.5. Viewing an Alarm Triggered Channel ...64 14.6. Viewing Images with Digital Zoom...64 14.7.
  • Page 8 Table of Contents Configuration...73 16.1. Quick Setup...73 16.1.1. Date/Time ...73 16.1.2. Recording ...76 16.2. Camera ...77 16.3. Normal Record..81 16.3.1. Setting Global DRS5016 / 5116 Models Only ...81 16.3.2. Setting by Channel ...82 16.4. Alarm Rec...85 16.4.1. Setting Sensor ...85 16.4.2.
  • Page 9 Table of Contents Advanced Configuration... 107 Connecting External Device...107 17.1. Using Text Device ...107 17.1.1. Setting at Text Menu ...107 17.1.2. Setting at Serial Setup’s RS232 Menu ...108 17.1.3. Setting at Alarm Rec. Menu ...109 17.1.4. Setting at Normal Rec. menu ...109 17.2.
  • Page 10: Overview

    RS232, RS485/422 PTZ Control 32bit True-Color Graphic OSD Menu Dynamic IP (DHCP), Floating IP Support IR Remote Controller/PTZ Control Network Client Software CCTV Monitor Output 19” Rackmountable Wren DRS5004 DRS5008 DRS5016 series series Max 60ips Max 60fps Max 120fps 30 / 25 30 / 25 Y–shelf...
  • Page 11: Component List

    3. CD-ROM (Including DVR manager) (1EA) 5. Guide (2EA) Wren DRS5116 2. AC/DC Power Cord (1EA) * DRS5004 / 5008 require DC adaptor * 4. Remote Controller (1EA) 6. 19” RACK FIXING KIT (1SET) * DRS5016 / 5116 models only *...
  • Page 12: Description & Function

    Overview DRS5116 3. Description & Function DRS5116 Front (1) Power switch (2) Function buttons (3) LED (4) I/O Port cover (5) USB connector (6) IEEE1394 connector (7) Remote controller receiver Wren 2003. 09. 06 (v 1.0)
  • Page 13 Overview DRS5116 DRS5116 Rear (8) BNC connector for video input (9) AC power connector (10) BNC connector for video output (11) BNC connector for monitor A output (12) BNC connector for monitor B output (13) Terminal block for sensor, relay, and serial input/output (14) IEEE1394 connecter (15) Terminal block for RS232 &...
  • Page 14 Overview DRS5116 DRS5004 Front Panel (1) LED (2) IEEE1394 connecter (3) Remote controller receiver (4) USB connecter (5) Function buttons (6) Bracket fixing hole for rack mount Wren 2003. 09. 06 (v 1.0)
  • Page 15 Overview DRS5116 DRS5004 Rear Panel (7) Power switch (8) Ethernet connector (9) BNC connector for Video input (10) Audio input/output connector (11) RS232 connecter (9Pin D-Sub) (12) Terminal block for RS232 & 422/485 (13) Terminal block for Sensor input (14) Terminal block for relay output (15) Video output for Monitor or VCR (16) Video input type/impedance select &...
  • Page 16 Overview DRS5116 DRS5008 Front Panel (1) LED (2) IEEE1394 connecter (3) Remote controller receiver (4) USB connecter (5) Function buttons (6) Bracket fixing hole for rack mount Wren 2003. 09. 06 (v 1.0)
  • Page 17 Overview DRS5116 DRS5008 Rear Panel (7) Power switch (8) Ethernet connector (9) BNC connector for Video input (10) Audio input / output connector (11) RS232 connecter (9Pin D-Sub) (12) Terminal block for RS232 & 422/485 (13) Terminal block for Sensor input (14) Terminal block for Relay output (15) Video output for Monitor or VCR (16) Video input type/impedance select &...
  • Page 18: Installation And Connection

    Installation and Connection Installation and Connection 4. Connecting & Running 4.1. Connecting Camera (1) Connect the CCTV camera to the DRS with the BNC cable as shown below. <Note> 1. The video type for all channels should be either NTSC or PAL. 2.
  • Page 19: Connecting Monitor

    <Note> The DRS5116 has two monitor output ports for A (Normal) and B (Spot). When connecting only one monitor, use monitor A. DRS5004/5008/5016 have single monitor outputs. 4.3. Connecting Audio (1) Connect the audio signal to the DRS using the RCA cable.
  • Page 20: Supplying Power

    Installation and Connection DRS5116 4.4. Supplying Power (1) Connect the power cable. * Care should be taken to apply proper voltage to avoid damage to the DRS Unit * DRS5004 DRS5008 DRS5016 DRS5116 12VDC supplied 12VDC supplied 110 ~ 220VAC 110 ~ 220VAC DRS5016 &...
  • Page 21 Installation and Connection DRS5116 DRS5004 & DRS5008 (1) Connect the power cable. (2) Turn on the power switch located on the DRS rear panel. Wren 2003. 09. 06 (v 1.0)
  • Page 22: Running Osd Menu

    Installation and Connection 5. Running OSD Menu 5.1. Using Menu Press the [MENU] button to open the OSD Configuration menu. (1) Main Menu (2) Sub-Menu (3) Setting Page (1) Main Menu Tabs: The selected tab is shown in blue and the related sub-menus will be shown below the tab.
  • Page 23: Dialogue Box To Edit A Word

    Installation and Connection 5.2. Dialogue Box to Edit a Word There are two methods to set a word. (1) Using the number button, enter the related numbers in order of horizontal/vertical. (For example, in order to select “C”, press the [3] and [2] buttons) (2) Using the arrow button, select a value using the [◄◄...
  • Page 24: Setting Remote Controller

    Installation and Connection 6. Setting Remote Controller 6.1. Setting ID of DRS Digital Recording Solution When controlling several DVRs with one remote controller, set Remote Control ID as follows: (1) Press the [MENU] button. (2) Select “System” using the [►►] button and press the [ENETR] or [▼] buttons. (3) Select “Miscellaneous”...
  • Page 25: Selecting Drs

    Installation and Connection 6.2. Selecting DRS If several DVRs are set with unique ID numbers, they can be controlled with one remote controller. To select a specific (DRS), keep pressing the ID button on the remote controller until a buzzer sounds during the first two seconds.
  • Page 26: Drs Configuration

    Installation and Connection DRS5116 7. DRS Configuration 7.1. Basic Configuration * Camera/Sensor/Rely/Monitor Quantities are Model Dependant * 7.2. Advanced Configuration Wren 2003. 09. 06 (v 1.0)
  • Page 27: External Storage & Backup Configuration

    Installation and Connection DRS5116 7.3. External Storage & Backup Configuration 7.4. Internet/Intranet Configuration Wren 2003. 09. 06 (v 1.0)
  • Page 28: Drs Basic Setting

    Installation and Connection DRS5116 DRS Basic Setting 8.1. Viewing Image After the initial start-up, images are displayed in a multi-split screen according to the connected channels and specific model being installed. The following example is when four channels are connected. <Note>...
  • Page 29: Setting Date & Time

    Installation and Connection DRS5116 8.2. Setting Date & Time (1) Press the [MENU] button, and select the “Quick Setup” tab. (2) Select “Date/Time” and enter the Settings Page by pressing the [ENTER] button. 8.2.1. Time Zone (1) Select the “Time Zone” and press the [ENTER] button to configure. (2) Select a value using the [◄◄/►►] buttons and press the [EXIT] button when finished.
  • Page 30: Time Format

    Installation and Connection DRS5116 8.2.4. Time Format (1) Select “Time Format” using the [◄◄/►►] or the [▲/▼] buttons and press the [ENTER] button. (2) Two Time Formats are available; ‘MM/DD/YYYY’ and ‘YYYY/MM/DD’. Select a value using the [▲/▼] buttons, and press the [EXIT] button when finished. (Default value is ‘MM/DD/YYYY’) 8.2.5.
  • Page 31: Setting Recording Condition

    Installation and Connection DRS5116 8.3. Setting Recording Condition Recording conditions under the “Quick Setup” menu tab will apply the same values to all analog channels 1~16. All settings are applied for 24 hours/day regardless of the values set for “Time Schedule” or “Alarm Rec.”...
  • Page 32: Channel Status

    Installation and Connection DRS5116 8.3.2. Channel Status (1) Select “Channel Status” using the [▲/▼] buttons and press the [ENTER] button. (2) Select a value using the [◄◄/►►] buttons. Press the [EXIT] button when finished. 8.3.3. Recording Speed/Quality (1) Select “Recording Speed/Quality” using the [▲/▼] buttons and press the [ENTER] button. (2) Select a value using the [◄◄/►►] buttons.
  • Page 33: Connecting And Configuring Dio Ports

    Installation and Connection 9. Connecting and Configuring DIO Ports <Note> Wire Handling When connecting a wire to a terminal block, follow the instructions below. Note the different types of wire that can be used. Inserting & Removing Wire To insert the wire, use a screwdriver as shown in the diagram to the right.
  • Page 34: Connecting And Configuring Sensor

    Installation and Connection 9.1. Connecting and Configuring Sensor 9.1.1. Specification In order to run sensor input of DRS series normally, the following conditions are required: Input Ch. Input type Spec. Supported sensor Connecting Available input pulse range Performance Output current 9.1.2.
  • Page 35: Configuring Sensor At Osd Menu

    Installation and Connection DRS5116 9.1.3. Configuring Sensor at OSD Menu * DRS5016 / 5116 Models * (1) Press the [Menu] button, and select the “Alarm Source” among OSD menus. (2) Select the “Sensor” menu and press the [Enter] button to move to the sub-menu. 9.1.3.1.
  • Page 36 Installation and Connection DRS5116 * DRS5004 Model * (1) After a sensor is connected, it can be activated through the OSD Configuration menu. Select the sensor number (S1, S2, etc.) and press the [Enter] button to configure. Use the [◄◄/►►] buttons to select “On” or “Off.” Press the [EXIT] button when finished.
  • Page 37 Installation and Connection DRS5116 (1) After a sensor is connected, it can be activated through the OSD Configuration menu. (2) Select the sensor number (S1, S2, etc.) and press the [Enter] button to configure. Use the [◄◄/►►] buttons to select “On” or “Off.” Press the [EXIT] button when finished. (3) When activated, the “Pre/Post Alarm”...
  • Page 38: Connecting & Configuring Relay Out

    Installation and Connection 9.2. Connecting & Configuring Relay Out 9.2.1. Specifications In order to operate the relay outputs of the DRS Digital Recording Solution (all models) normally, the following conditions are required. Output Ch. Spec. Output type Connecting type Rating 9.2.2.
  • Page 39: Configuring Relay Out At Osd Menu

    (Weekday/(Day), Weekday/(Night), Weekend/(Day), Weekend/(Night)). Relays can also be controlled locally by pressing the [SEARCH/RELAY] button followed by the relay number (1-4). Relays can also be controlled remotely through the “DVR Manager software.” * DRS5004 Model * * DRS5008 Models * Wren...
  • Page 40: Connecting Serial Port

    Installation and Connection DRS5116 * DRS5016/5116 Models * <Note> (1) For detailed information for setting, please refer to the “ DRS Programming Guide”.. 9.3. Connecting Serial Port 9.3.1. Configuring Serial Ports for Pan/Tilt/Zoom The DRS series units have most major PTZ protocols already pre-programmed. Certain makes and models not supported can still be controlled using the Transparent Protocol.
  • Page 41: Diagrams Of Serial Ports

    Installation and Connection DRS5116 9.3.2. Diagrams of Serial Ports 9.3.2.1. Diagram of COM1 9.3.2.2. Diagram of COM2 Wren 2003. 09. 06 (v 1.0)
  • Page 42: Diagram Of Com3

    Installation and Connection DRS5116 9.3.2.3. Diagram of COM3 9.3.2.4. Diagram of COM4 9.3.3. View of COM3/COM4 Serial Ports Wren 2003. 09. 06 (v 1.0)
  • Page 43: Configuring Com Port At Osd Menu

    Installation and Connection DRS5116 9.3.4. Configuring COM Port at OSD Menu Configure PTZ COM ports and available modes at “System/Serial Setup”. After completing serial setup, configure the base address and port for each channel under the “Camera” menu tab. When connecting PTZ devices to several cameras, be sure the base address matches the address for the camera.
  • Page 44: Connecting External Device With Serial Port

    Installation and Connection DRS5116 9.4. Connecting External Device with Serial Port 9.4.1. Connecting Text Input Device (ATM/POS/Access Control) In addition to images, the DRS units can record text data received from POS/ATM through the COM1/RS232 serial port. Connect to COM1/RS232 (9pin D-Sub) of the DRS5116, and configure the “Serial Setup” sub-menu under the “System”...
  • Page 45: Configuring Text

    Installation and Connection DRS5116 9.4.3. Configuring Text (1) Select the “Alarm Source” menu among OSD menus. (2) Select the “Text”, and set each value. <Note> Before installing any external device, consult with the local distributor. Some external devices may not be compatible with the DVR.
  • Page 46: Connecting Usb Device

    Installation and Connection 9.5. Connecting USB Device The USB port can be used to copy up to one minute of images to a USB Flash memory disk. When connecting a USB device, do not exceed the rated values of the USB device. USB Spec.
  • Page 47: Connecting Video In/Output

    Installation and Connection DRS5116 <Note> 1. The USB Flash products that require a Windows program to operate may not be recognized by the DVR. 2. For more information about the copy function, refer to the “ DRS Programming and Maintenance Guide”.
  • Page 48: Wren 2003. 09. 06 (V 1.0)

    Installation and Connection 10. Connecting External Storage 10.1. IEEE1394 Port DRS5116 series have two IEEE1394 ports for external storage device interface. With them, the DRS series can expand storage capacity up to 4TB. <Note> Some IEEE1394 bays may not be recognized by the DRS series. Before purchasing, consult the local distributor.
  • Page 49: Network Monitoring & Managing

    Installation and Connection DRS5116 11. Network Monitoring & Managing The DRS can be accessed, controlled, and managed from a remote site via Internet/Intranet. 11.1. Connecting Ethernet (1) Turn off the DRS power switch. (2) Connect the DRS to hub with Ethernet cable. (3) Turn on the DRS power switch.
  • Page 50: Configuring Drs Network Information

    Installation and Connection DRS5116 11.2. Configuring DRS Network Information The following description is on based on Ethernet connection. For more detailed information on the Network Settings Page, please refer to the “ DRS Programming and Maintetnance Guide”. (1) Press the [MENU] button. (2) Select “System”...
  • Page 51: Using Dvr Manager

    Installation and Connection 12. Using DVR Manager 12.1. PC System Requirements for running DVR Manager Minimal Requirements P-Ⅲ 600MHz or above 128 MB or above 16 MB or above Windows 2000/XP Resolution 1024 X 768 pixels or above Network 100 Base TX Fast Ethernet 12.2.
  • Page 52 Installation and Connection DRS5116 (4) Select which components to install and press the “Next” button. (5) Browse and choose a directory if the default directory is not preferred. Click the “Install” button, after selecting a directory to install. (6) Click the “Close” button after the DVR Manager program is installed successfully. Wren 2003.
  • Page 53: Uninstalling Dvr Manager

    Installation and Connection DRS5116 12.3. Uninstalling DVR manager (1) Click Windows “Start” Button. (2) Select and click the ‘Uninstall’ icon to run the Uninstall Shield. (3) The DVR Manager program will be automatically deleted. 12.4. Configstation Click icon on desktop to run “DVR Manager Configstation” program. Wren 2003.
  • Page 54: Monitor

    Installation and Connection 12.5. Monitor Click the related icon and run the “DVR Manager Monitor” program. 12.6. Playback Click the related icon and run the “DVR Manager Playback” program. Wren DRS5116 2003. 09. 06 (v 1.0)
  • Page 55: Product Description

    Installation and Connection DRS Digital Recording Solution Programming and Maintenance 13. Product Description 13.1. Front Panel DRS5016 / 5116 Models (1) LED (4) IEEE 1394 & (5) Function selection USB Interface button (1) LED PWR : Displays power status. When lit, power is supplied. : Displays the status of Ethernet connection and rate of communication.
  • Page 56: Rear Panel Drs5016 / 5116 Models

    Product Description manager. LOCK : Displays screen lock status (2) Remote Controller Receiver (3) Power Switch For power off, press the power switch for 5 seconds. (4) IEEE 1394 & USB Interface Supports each one port for IEEE1394 and USB 13.2.
  • Page 57: Front Panel Drs5008 Model

    Product Description RS232 : RJ45 connector RS422/485 : RJ45 connector IEE1394 13.3. Front Panel DRS5008 Model (1) Remote Controller (2) Channel Receiver Selection Button (5) Remote Controller Receiver (6) Channel Selection Button - To select a video input channel in monitoring and playback mode (7) LED - PWR: Displays power status.
  • Page 58: Rear Panel Drs5008 Models

    Product Description (8) Function selection button - SEQ: To select the sequencing mode. HVR-08E will automatically display all connected channels in successive order. - MULTI: To select the multi-channel display (4-9-divided screen). - SELECT: To select a video channel for PTZ control in the Monitor mode and for Copy/Backup/Delete in Playback mode - ZOOM: To activate the digital zoom (single channel mode only).
  • Page 59: Front Panel Drs5004 Series Models

    Product Description 1 monitor output & 1 VCR output (5) Video Input 8 video inputs (7) Ethernet (8) Power 13.5. Front Panel DRS5004 Series Models (1) Remote (2) Channel Controller Receiver Selection Button (1) Remote Controller Receiver (2) Channel Selection Button...
  • Page 60 Product Description ALARM: 1~4 (4) Function selection button SEQ: To select the sequencing mode. HVR-04E will automatically display all connected channels in successive order. MULTI: To select the multi-channel display (4-9-16-13 divided screen). SELECT: To select video channel for PTZ control. ZOOM: To activate the digital zoom (single channel mode only).
  • Page 61: Rear Panel Drs5004 Models

    HELP: To change the image information display (Date, Transfer speed, etc). EXIT/LOCK: To exit form the selected menu or lock current screen. Arrow key: Replay function or to move inside the Configuration menu. 13.6. Rear Panel DRS5004 Models (2) Audio port (1) Serial Port &...
  • Page 62: Basic Configuration

    Basic Configuration Basic Configuration 14. Monitoring Once power is applied to the DRS Digital Recording Solution, all connected channels will be displayed by the 4/8/16 split monitoring mode. Solution’s monitoring menus. 14.1. Viewing Basic Screen (Quad- Split) - Insert the AC cord’s plug in a wall outlet, and apply power to the unit.
  • Page 63: Viewing All Channels With Sequence Mode

    Basic Configuration DRS5116 14.4. Viewing all Channels with Sequence Mode - All channels can be viewed in successive order automatically using the [SEQ] button. - Press the [MENU] button on the front panel to set-up the sequential cycle. (The default value is 3 seconds per channel for display.) - Select the “Monitor”...
  • Page 64: Viewing An Alarm Triggered Channel

    Basic Configuration 14.5. Viewing an Alarm Triggered Channel - When an alarm is triggered, the related channel will automatically pop-up full screen. - Set ‘Alarm Pop-up Screen’ function to “On” in “Configuration” under the “Monitor” tab, and set the display duration in “Pop-up Hold (sec)” - If more than one channel is triggered by an alarm, the related channels will be displayed simultaneously in a split-screen.
  • Page 65: Controlling Zoom/Focus

    Basic Configuration 14.7.2. Controlling Zoom/Focus To control Zoom and Focus during live image monitoring mode: - Press the [SELECT] button. Move the “Select” icon to the desired channel. - Press the [MENU] button. - Select ‘Zoom/Focus’ from the PTZ Menu. - Control Zoom and Focus functions using the up, down, left and right arrows of front panel.
  • Page 66: Using Screen Lock

    Basic Configuration 14.9. Using Screen Lock The screen lock is used to lock againt unauthorized users when the administrator is not at his desk. - For this function to operate properly, the user password should be set. - While pressing the [EXIT/LOCK] button for 2~3 seconds, the Lock mode will run with a “Screen Locked”...
  • Page 67: Using Monitor B Drs5116 Model Only

    Basic Configuration 14.10. Using Monitor B DRS5116 Model Only 14.10.1. Monitoring Monitor A is used for monitoring multi-channels, and Monitor B is used for monitoring a single-channel. The user can monitor channels as shown in the following tables. Monitor A Monitor B 16-split screen mode 1ch monitoring...
  • Page 68: Ch Playback

    Basic Configuration DRS5116 14.10.3. 1 Ch Playback The administrator can monitor multi-cahnnels by split screen mode in Monitor A, and search/playback one channel by single full screen in Monitor B simultaneously. 15. Playback Playback is used to replay recorded images in full screen or a split screen (4/9/16) mode depending on the model installed.
  • Page 69: Playback Ch5 To Ch16 Via Quad-Split Screen

    Basic Configuration 15.1.3. Playback Ch5 to Ch16 via Quad-Split Screen - Press the [SELECT] button in the quad-split mode. - Select a split position. - When a channel number is selected, the related image is played in the position. 15.1.4. Playback with Digital Zoom - Press the [ZOOM] button during the basic (single-channel) playback mode.
  • Page 70 Basic Configuration DRS5116 <Button control> - Press the [SEARCH] button in playback mode. - Search for data by entering Date/Time or by selecting an event from the Event Log browser. - Press the [ENTER] button after entering the desired Date/Time or select from the Event Log browser. - The selected images will begin to playback.
  • Page 71: Copy / Backup / Delete Data Manager

    Basic Configuration DRS5116 15.3. Copy / Backup / Delete Data Manager The Data Manager can be used to copy/backup/delete the recorded data. This menu is activated duringthe playback mode. - Press the [SELECT] button and the [MENU] button in the playback mode. 15.3.1.
  • Page 72: Backup Data

    Basic Configuration 15.3.2. Backup Data Start Date & Time / End Date & Time This menu is used to designate a backup range. The Select Disk menu is used to select which storage will be used as a backup device. To change the disk status, use the “Disk Manager”...
  • Page 73: Configuration

    Basic Configuration DRS5116 16. Configuration 16.1. Quick Setup There are three menus for recording setup; Quick Setup, Normal Recording and Alarm Recording menus in the Configuration Menu. Quick Setup is the easiest set-up,which activates all analog cameras (4 ~16 Model Dependant) to record with the same settings and conditions. Normal recording is the standard recording setting and can be customized based on time and channel.
  • Page 74 Basic Configuration DRS5116 - In order to access each menu, press the [ENTER] button after selecting it with the upward/downward arrow buttons on the DRS front panel. Time Zone Set the time zone using the left/right arrow button on the DRS front panel. Every time you press the left/right arrow button, the time zone will change.
  • Page 75 Basic Configuration It is to synchronize time with NTP (Network Time Protocol) server. <Note> For more detailed information about the NTP setting, please refer to the “Network Configuration” (System Network NTP Settings). Set the time format between “MM/DD/YYYY” and “YYYY/MM/DD” using the the left/right arrow buttons on the DRS front panel.
  • Page 76: Recording

    Basic Configuration DRS5116 16.1.2. Recording Its recording values are applied to all active channels (4~16 Model Dependant) for all time periods. <Button control> - Press the [MENU] button and select “Recording” from the “Quick Setup” tab. Configuration Status The Configuration Status displays the recording setup status. If the recording is configured with the “Quick Setup”, ’Macro Setup’...
  • Page 77: Camera

    Basic Configuration DRS5116 Audio Recording If the audio is set as “On,” and “Audio Synch with” is set as “All” (in the “Audio” menu under the “System” tab), the audio will be available in the playback mode with all channels. Apply The “Apply”...
  • Page 78 Basic Configuration DRS5116 * DRS5004 Model OSD Menu * <Button control> - Press the [MENU] button and use the [ARROW] keys to move to each channel below the “Camera” tab. Name Assign a customized name to the channel. Press the [ENTER] button to open the necessary dialogue box.
  • Page 79 Basic Configuration <TIP> When assigning a name to a channel, the following dialogue box will appear. This box is also used later in the system, but the method is always the same. - To select a letter, use the [ARROW]/(◄◄ and ►► ) buttons or the number buttons, “0” to “9” on the DRS5116 front panel.
  • Page 80 Basic Configuration DRS5116 Set “On/Off” using the [◄◄/►►] buttons. Type The type menu displays the NTSC/PAL video type set with the internal jumper. NTSC is the factory default. Color Select Color/BW using the [◄◄/►►] buttons. AGC (Auto Gain Control) Select “ON/OFF” using the [◄◄/►►] buttons. Brightness/Contrast Set the value between –9 and +9 using the [◄◄/►►] buttons.
  • Page 81: Normal Record

    Basic Configuration DRS5116 16.3. Normal Record. This menu is used for configuring the normal recording settings based on the channel and timetable. If recording values were programmed with the Quick Setup Menu, the previous Quick Setup values will be replaced by the Normal Recording settings. 16.3.1.
  • Page 82: Setting By Channel

    Basic Configuration 16.3.2. Setting by Channel Each camera can be set to record based on four time schedules: (1) Weekday (Day) (2) Weekday (Night) (3) Weekend (Day) (4) Weekend (Night) Each schedule can be configured under the “System” tab. Wren DRS5116 Time Schedule 2003.
  • Page 83 Basic Configuration DRS5116 <Setting Time Schedule> Used to set time schedule, move to “System” menu. Weekday Start/End Press the [ENTER] button to access the Time Setting. Set the range for “Weekday” between Monday and Sunday using the [◄◄/►►] buttons. “Weekend” is set automatically based on the “Weekday” range.
  • Page 84 Basic Configuration DRS5116 Special Time Recording This menu is used to designate different recording conditions during “Special Times.” The “Special Time” is designated under the “System” tab. There are five conditions; No Rec./Low/Standard/High/Custom (same as above). <Setting Special Time> To set ”Special Time,” move to “System” tab. Up to four zones can be designated as “Special Time.”...
  • Page 85: Alarm Rec

    Basic Configuration DRS5116 16.4. Alarm Rec. This menu isused to configure the settings for alarm recording conditions. To activate this schedule set: (1) Turn the “Event Recording” under the “Normal Recording” tab to “On.” (2) The “Alarm Source” should be set before the alarm recording menu. 16.4.1.
  • Page 86: Setting Motion Detection

    Basic Configuration DRS5116 16.4.2. Setting Motion Detection This screen is used for setting each MD condition per channel. “Global” means to set all channels by same MD condition. It is possible to set each channel separately. Motion Detection Choose from among four sensitivity conditions; Off, Low, Standard, and High. MD Area Customize the MD area among 64 sectors (8 sectors x 8 sectors).
  • Page 87: Text

    Basic Configuration DRS5116 Area <Setting MD > Designate a specific area for motion detection triggered event. Press the “Custom Area” button, to customize the motion detection area. The area is divided into 64 blocks (8 x 8). The selected MD area is indicated in dark gray. To remove blocks from motion detection, select the block using the [ARROW] buttons and press the [ENTER] button.
  • Page 88: Setting Global Alarm Recording

    Basic Configuration DRS5116 menu is used to set input text information. For text recording, the “COM1” port should be also set in the “System Serial Setup” menu. Sync Text With This function is used to set the channel to synchronize with text. Seek Header If a protocol is built in DRS, like Star Finger 007, this setting is needless.
  • Page 89 Basic Configuration DRS5116 Sensor/MD Set the co-work of sensor/MD. Pairing means thechannel runs sensor/MD by 1 to 1. Text In order to display or record text with an image, it should be set as “On”. <Note> 1. After setting it as “Global”, press the “Apply” button. 2.
  • Page 90: Setting By Channel

    Basic Configuration DRS5116 16.4.5. Setting by Channel Alarm Source (*=All) - With the “Alarm Source” menu, it is possible to select up to 4 sensor/MD and text input. - For setting sensor/MD, press the related number button. - Set text as “On/Off” with the [ARROW] button. - Set a PTZ preset position according to the alarm input.
  • Page 91: Alarm Act

    Basic Configuration DRS5116 16.5. Alarm Act. The Alarm Act is used to set relay command for each time schedule; Weekday(Day), Weekday(Night), Weekend(Day), Weekend(Night). In order to make alarm action run after setting schedule, the Relay, Buzzer, and E-mail should be also configured. 16.5.1.
  • Page 92: Setup

    Basic Configuration DRS5116 16.5.2. Setup Relay Configuration The Relay Configuration enables R1~R4. Buzzer The Buzzer enables an alarm buzzer when an alarm (MD or sensor) is triggered. E-mail Notification DRS5116 Model Only The E-mail Notification allows user to enter E-mail address to receive alarm information. SMTP The SMTP enters the DNS of mail relay server.
  • Page 93: Monitor

    Basic Configuration DRS5116 16.6. Monitor This menui s used to display an image on Monitor A & Monitor B. Alarm Pop-up (sec) This function is used to set the alarm pop-up screen. . The pop-up duration time can be set between 5 and 10 seconds.
  • Page 94: Monitor

    Basic Configuration DRS5116 16.7. Monitor This menu is used to displayan image on monitor A & monitor B. Alarm Pop-Up (sec) This function is used to set the alarm pop-up screen. The pop-up duration time can be set between 5 and 10 seconds.
  • Page 95: System

    Basic Configuration DRS5116 16.8. System 16.8.1. Audio The DRS units support 1 channel audio input. This single audio channel can be replayed with any connected channel or with all of them. Recording Set to “On” using the [ENTER] button and the [ARROW] buttons to record audio. Audio Gain This function increases or decreases the sensitivity to the audio signal;...
  • Page 96: Time Schedule

    Basic Configuration DRS5116 16.8.2. Time Schedule This screen is used to designate Weekday/Weekend and Day/Night. Weekday Start/End Press the [ENTER] button to access the Time Setting. Set the range for “Weekday” between Monday and Sunday using the [◄◄/►►] buttons. The “Weekend” is set automatically based on the “Weekday”...
  • Page 97: Special Time

    Basic Configuration DRS5116 16.8.3. Special Time Up to four zones can be designated as “Special Time.” Wren 2003. 09. 06 (v 1.0)
  • Page 98: Security

    Basic Configuration 16.8.4. Security Designate a User’s Password for access to monitoring and playback. The default password is “0000”. Designate an Administrator’s Password to control access to the Configuration menu and full system control authority. The default password is “9999”. When the remote setup is set to “Enable,”...
  • Page 99: Disk Setup

    Basic Configuration 16.8.5. Disk Setup Images and data recorded under the “Normal” condition are automatically deleted as the hard-drive(s) reach capacity. Images are written over based on a first-in/first-out basis. Images recorded based on “Alarm” conditions are not written over. If enabled, all images, “Normal”...
  • Page 100: Network

    Basic Configuration DRS5116 16.8.6. Network There are five sub-menus: Network, xDSL, HRS, Port Setting, and NTP Setting. 16.8.6.1. Network This page is used to define the network type and se tthe network addresses for the DRS. Type This is to select proper network interface (Ethernet/xDSL) with which the DRS is connected. If theDRS is connected with an Internet dedicated line, a cable modem line or on a LAN environment, select the network interface as ‘Ethernet’.
  • Page 101: Xdsl

    Basic Configuration DRS5116 DHCP can also be used for xDSL (PPPoE) interface. Sometimes, all computers on a Local Area Network (LAN) share a single Floating / Dynamic IP address. In this case, the DRS should be assigned a private IP address and have the DHCP enabled. Users on the LAN can connect to the DRS using the private IP address and outside users can connect to the DRS over the Internet.
  • Page 102: Port Setting

    Basic Configuration DRS5116 16.8.6.3. Port Setting Monitoring Port/Playback Port The DRS uses port 8001 for monitoring and port 8105 for playback. To change the port number to an open port (some firewalls and/or ISPs block certain ports), press the [ENTER] button and use the dialogue box.
  • Page 103: Ntp Setting

    Basic Configuration DRS5116 16.8.6.4. NTP Setting NTP (Network Time Protocol) makes the time of Network devices synchronize. They are composed of a central server for supplying standard time via Network and a client for receiving the synchronized time with connecting the server NTP Mode Set the DRS5116’s NTP mode between Client and Server.
  • Page 104: Serial Setup

    Basic Configuration DRS5116 16.8.7. Serial Setup TheDRS Units have a total of 4 COM ports. Device Designate the connected external device. Interface The interface is used to designate the protocol on the RS422/RS485 menu. COM1 and COM3 are fixed as RS232. Baud rate/Parity/Stop (bit)/Data (bit) Each value should be set according to the specifications of the connected external device.
  • Page 105: Miscellaneous

    Basic Configuration DRS5116 16.8.8. Miscellaneous <Button control> - Press the [MENU] button and select “Miscellaneous” below the “System” tab. Remote Control ID Up to sixteen DRS units can be controlled with a single IR Remote Control. Designate each unit with a unique number under the ‘Remote Control ID’...
  • Page 106 Basic Configuration DRS5116 collided. In this case, the default value should be changed. Keyboard PTZ Addr This function is used to set the keyboard’s PTZ address in order to operate each PTZ camera with a keyboard. When setting the first camera’s address of each DRS5116, another cameras’ are designated automatically.
  • Page 107: Advanced Configuration

    Advance Configuration DRS5116 Advanced Configuration 17. Connecting External Device 17.1. Using Text Device In order to use the text device, the following four menus should be set; Text menu, Serial Setup’s RS232 menu, Alarm Rec. menu, and Normal Rec. menu 17.1.1.
  • Page 108: Setting At Serial Setup's Rs232 Menu

    Advance Configuration DRS5116 17.1.2. Setting at Serial Setup’s RS232 Menu Set RS232’s device menu as “Text”. Then set the baud rate, parity, stop, and data. Wren 2003. 09. 06 (v 1.0)
  • Page 109: Setting At Alarm Rec. Menu

    Advance Configuration DRS5116 17.1.3. Setting at Alarm Rec. Menu - Set the text event as “On”. 17.1.4. Setting at Normal Rec. menu Wren 2003. 09. 06 (v 1.0)
  • Page 110: Using Keyboard

    Advance Configuration DRS5116 - Set the event recording as “On” for each time schedule. <Note> Whenever pressing the “Help” button, information of the displayed image is different. The default value of the monitoring mode is to show only the channel number. Then the next step is to show the channel name and text, event status, and HDD status.
  • Page 111 Advance Configuration WARRANTY INFORMATION Wren warranties all of its DVRs for one (1) year. The hard disk drives are under warranty for one (1) year from date of sale against any defects in material or workmanship as long as the product is used for the purposes for which it was intended.
  • Page 112 Wren and the Wren logo are trademarks of Wren Associates, Ltd. All other trademarks and/or registered trademarks mentioned herein are properties of their respective owners and are used for reference purposes only. The use of these trademarks does not indicate any affiliation with or sponsorship of or by Wren Associates, Ltd.

This manual is also suitable for:

Drs5008Drs5116Drs5016

Table of Contents