(3) Adjustment of Oil Drip Rate (Fig. 4)
① Set the air pressure to the motors recommended
maximum air pressure.
② Adjust the Oil Drip Rate to the recommended
volume which is 1 to 3 drops / min.
O direction
S direction
8 - 3 ON / OFF Valve (Fig. 5)
Turn the ON / OFF Lever located on the valve 90-Degrees
to turn the air output ON (Open) or OFF (Close).
8 - 4 Tool Holder (Fig. 6)
When not use the Air Tool can be stored.
9 . INSTALLATION AND CONNECTION OF THE AIR LINE KIT
CAUTION
The Air Line Kit install to the horizontal. If " Rear Mounting ", install the Air Line Kit to the
horizontally on a vertical wall.
9 - 1 Installation of the Air Line Kit
(1) Horizontal Installation
When the Air Line Kit is mounted from the bottom in a horizontal position Af¿x the Rubber Pads
(Standard Accessories : 4pcs.) to the bottom of the Air Line Kit.
(2) Rear Mounting or Bottom Mounting
Attach the Air Line Kit by the Mounting Screws (Cross-Recessed Truss Tapping Screw : M6 x 20)
(Standard Accessories : 4pcs) or M6 screw (not included / provided by the end-user) (Fig . 7).
* When Rear Mounting, attach using the Washers (Standard Accessories) between mounting surface and rear
surface of the Base Plate with on horizontal attitude.
4 - 7
20
260
Bottom
:
Increase.
:
Decrease.
(20)
Fig. 7
O : Increase
Adjusting Dome
Fig. 4
Valve
Fig. 5
Fig. 6
2 - 7
20
260
300
Rear
S : Decrease
ON (Open)
OFF (Close)
Tool Holder
(20)
17