SPECIFICATIONS
Input
Output
Voltage
Voltage
Range
20-30 VDC
13.8 VDC
(1)(2)(3)
ICT2412-10AH
+/- 300 mV
20-30 VDC
13.8 VDC
(1)(2)
ICT2412-12AH
+/- 300 mV
20-30 VDC
13.8 VDC
(1)(2)
ICT2412-15AH
+/- 300 mV
13.8 VDC
(1)(2)(3)
20-30 VDC
ICT2412-20AH
+/- 300 mV
20-30 VDC
13.8 VDC
(1)(2)
ICT2412-30AH
+/- 300 mV
13.8 VDC
(1)(2)
20-60 VDC
ICT4812-10AH
+/- 200 mV
20-60 VDC
13.8 VDC
(1)(2)
ICT4812-15AH
+/- 200 mV
NOTE: These converters can be mounted on a standard 19" Rackmount.
Please contact us for more information.
CONNECTIONS
4 Terminal Type, No Remote Control
GND
Input
GND
Industrial Power
GND
Input +
Output +
Output
GND
Output
Current
Line
Load
Current
Limiting
Regulation
Regulation
(Cont.)
10.0 Amps
10.5 Amps
0.50%
0.40%
+/- 5%
12.0 Amps
16.0 Amps
0.45%
0.30%
+/- 5%
14.0 Amps
20.5 Amps
0.45%
0.30%
+/- 5%
20.0 Amps
31.0 Amps
0.45%
0.30%
+/- 5%
28.0 Amps
42.0 Amps
0.45%
0.30%
+/- 5%
10.0 Amps
10.5 Amps
0.70%
0.60%
+/- 5%
15.0 Amps
20.5 Amps
0.70%
0.70%
+/- 5%
5 Terminal Type, With Remote ON/OFF Control
From Batteries
Series
To Load
Output
Over-
Efficiency
Fuse
Ripple
voltage
(Typical)
(Max)
Protection
40 mV RMS
16.0 VDC
86%
10 Amp
40 mV RMS
16.0 VDC
88%
15 Amp
40 mV RMS
16.0 VDC
88%
20 Amp
40 mV RMS
16.0 VDC
95%
35 Amp
40 mV RMS
16.0 VDC
95%
35 Amp
20 mV RMS
18.5 VDC
85%
10 Amp
25 mV RMS
18.5 VDC
85%
20 Amp
(1)
CSA C22.2 No 107.1, UL 1012 Approved
(2)
CSA C22.2 No 213, UL 1604 Approved
(3)
Remote ON/OFF Control Version
GND
From Batteries
Input
GND
GND
Industrial Power Series
REMOTE
Input +
Output +
Output
To Load
GND
THEPOWEROFRELIABILITY
ICT INDUSTRIAL SERIES
HAZARDOUS LOCATIONS
INSTRUCTION MANUAL
855-002-025

Advertisement

loading

Summary of Contents for ICT INDUSTRIAL Series

  • Page 1 Voltage Current Limiting Regulation Regulation Ripple voltage (Typical) Voltage Range (Cont.) (Max) Protection ICT INDUSTRIAL SERIES HAZARDOUS LOCATIONS 20-30 VDC 13.8 VDC 10.0 Amps 10.5 Amps 0.50% 0.40% 40 mV RMS 16.0 VDC 10 Amp (1)(2)(3) ICT2412-10AH +/- 300 mV...
  • Page 2 Mount converter securely. omissions. RISQUE D'EXPLOSION: Couper le courant ou If this ICT product is not in good working order, as outlined in the Do not apply power until unit is completely wired. s'assurer que l'emplacement est designe non above warranty, your sole remedy shall be repair or replacement as provided above.

This manual is also suitable for:

Ict2412-10ahIct2412-12ahIct2412-15ahCt2412-20ahIct2412-30ahIct4812-10ah ... Show all