Download Print this page

DECRYPTUM PR 2080TI/12 4U User Manual page 13

Hide thumbs Also See for PR 2080TI/12 4U:

Advertisement

4.
POWER SUPPLY UNIT
!
EACH POWER MODULE SHALL OPERATE WITHIN LIMITED
INPUT VOLTAGE RANGE AS DEFINED IN TABLE 1.
4.2
AC input voltage
Frequency
DC input voltage
Input current
4.3
Starting Current
Maximum starting current for each PM is 35A. Please consider this when
designing your power supply network.
4.4
Branch circuit breakers
If one branch is supplying 2 or 3 PMs, please use C25 circuit breaker.
For supplying each PM separately, please install C16 circuit breaker in each
branch.
DECRYPTUM PR 2080TI/12 4U. USER MANUAL
ATTENTION
MIN
RATED
200
200-240
47
50-60
192
240-336
<10A@200-240VAC/160-340VDC @full load
Table 1
MAX
UNITS
264
VAC
63
Hz
400
VDC
13