Download Print this page

Wolf ` AGE24 Specification Sheet page 2

Age series low profile heavy-duty gas griddle

Advertisement

INSTALLATION REQUIREMENTS:
1. A gas pressure regulator supplied with the unit must be
installed:
Natural Gas 5.0" (127 mm) W.C.
Propane Gas 10.0" (254 mm) W.C.
2. All models require a 6" (152 mm) clearance at both sides
and rear adjacent to combustible and non-combustible
construction.
3. These units are manufactured for installation in accordance
with ANSI/NFPA-70, National Electrical code.
An adequate ventilation system is required for Commercial
Cooking Equipment (NFPA No. 96). Information may be
MODEL
WIDTH
AGE24
24"
AGE36
36"
AGE48
48"
AGE60
60"
AGE72
72"
*These are nominal dimensions and can vary by +1.75" with adjustable legs.
**All Rear Grease option griddles have only one (1) grease drawer on the left side.
NOTE: In line with its policy to continually improve its product, Wolf Range Company
This appliance is manufactured for commercial use only and is not intended for home use.
F-36977 (02-08)
MODEL: AGE SERIES
LOW PROFILE HEAVY-DUTY
OVERALL
WORKING
DEPTH
HEIGHT*
HEIGHT*
33"
15½"
33"
15½"
33"
15½"
33"
15½"
33"
15½"
reserves the right to change materials and specifications without notice.
GAS GRIDDLE
obtained by writing to the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02169.
4. These units are manufactured for installation in accordance
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American
Gas Association, Accredited Standards Committee Z223
@ 400N. Capital St. NW, Washington, DC 20001, or the
Secretary Standards Council, NFPA, 1 Batterymarch Park,
Quincy, MA 02169-7471.
NOTE: In the Commonwealth of Massachusetts
All gas appliances vented through a ventilation hood or
exhaust system equipped with a damper or with a power
means of exhaust shall comply with 248 CMR.
5. This appliance is manufactured for commercial installation
only and is not intended for home use.
NO. OF
TOTAL
BURNERS
BTU/HR.
11³⁄₈"
2
60,000
11³⁄₈"
3
90,000
11³⁄₈"
4
120,000
11³⁄₈"
5
150,000
11³⁄₈"
6
180,000
NO. OF
APPROX.
DRAWERS**
SHP.WT.
1
285 lbs./129 kg
1
400 lbs./181 kg
1
480 lbs./218 kg
2
650 lbs./295 kg
2
790 lbs./358 kg

Advertisement

loading

This manual is also suitable for:

Age36Age48Age60Age72