should there be a link between l1, l2 and l3 for single phase as with N
2 comments:
Raz
March 1, 2025
@Raz
or should just the single L wire be connected to EITHER l1, l2 OR l3
Mr. Anderson
March 1, 2025
No, for single-phase Steamtec AIO (3KW, 4KW, 215~240V), the connection should be made to the designated terminals for single-phase wiring. L1, L2, and L3 are used for three-phase connections, so they should not be interconnected for a single-phase setup. Instead, follow the wiring diagram for single-phase installation.
Page 1
Steamtec AIO Steam Generator Manual DO NOT use locking pliers to over tight the DRAIN PIPE connection Please read the manual carefully before installation and keep the manual for further reference _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
1. Configuration List When receive the steam generator, please check if you have get complete set according to below chart or not, contact us immediately if any missing. Photos Item name Quantity Steam generator in stainless steel housing Controller+housing box, waterproof touch screen 1set Central function box Central function box power cord...
2. Introduction Thank you for choosing “Steamtec” AIO series steam generator with well-designed structure, steady performance and convenient installation. This steam generator can work with the steam room, to form a whole steam-bath system. The steam-bath is for removing tiredness, relaxing muscles and stimulating blood circulation.
3. Safety Warning This appliance is not intended for use by person with reduced physical, sensory or mental capabilities, under 16 years old, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
5. Parameters 5.1. Models, parameters and dimension (Only apply to European style voltage and phase) Room Dimension Model Power Phase Heating elements Voltage / Current Power wire Breaker volume (L*W*H) N*KW N*mm2 TOLO-30 2*1.5 215-240/13.6 3*2.5 2~3 TOLO-40 2*2.0 215-240/18.2 3*2.5 3~5 215-240/20.5...
Notice: The rated power is measured under single phase 230V, therefore the actual operating power under single phase 215-240V, 50/60Hz, or three phases 380-415V, 50/60Hz may be different from the rated value. 3KW and 4KW machine, can be only under 215-240V single phase. Please note the earth wire should not less than 1.5mm2.
6~60℃ 35~60°C 103*103*45 (CH) (43℉~140℉) (95℉~140℉) Table 3 Notes: AIO Controller can be installed inside the steam room. However, we recommend you to install the controller outside the steam room to extend its service life. Figure 4 AIO controller _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com...
6. Installation And Cautions 6.1. Installation cautions DO NOT use locking pliers to over tight the DRAIN PIPE connection. Before installation, MUST read all the install Cautions in this manual, on page 5. Selecting the proper steam generator In order to achieve comfort and relaxation, as well as energy efficiency, the selection of the correct steam generator model and size are as critical as design of the steam room itself.
Install in the roof Suitable for installation Install in the closet Install under the washing basin Install in the basement Figure 5 Places to install steam generator 6.3. Installation of Central function box Central function box should be installed near Size :18*14*5CM to the steam generator, as the cable for connecting the central function box and the...
Page 11
Figure 7 Central function box connectors 1. APP 7. Color lights 2. Steam room temperature sensor 8. Salt spray generator 3. Controller 9. Aroma pump 4. Steam room humidity sensor 10. Descaling pump 5. Fast steam switch 11. Connector to the steam generator 6.
cathode blue temperature sensor for water tank dc-12v water inlet valve dc-12v drain valve white Figure 8 Steam generator 12-core cable socket corresponding functions 6.4. Installation of controller and temperature sensor 6.4.1. Cautions The control wire and temperature wire should not be parallel to or intersect with the power wire.
Page 13
95.1 First step: open the hole on wall :95*95MM Depth:34MM The gap for The gap for Positioning Positioning Second step: Housing box into the wall at the gap, horizontal installation _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
Page 14
Tile molding surface Tile molding surface Third step: make the tiles cover the gap and keep in line with tiles Forth step: insert the controller into the housing box _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
Page 15
Real picture Figure 9 Controller installations 6.4.3. Installation of temperature sensor The temperature sensor is used to measure the temperature inside the control wire control wire steam room, so that the generator can housing box work automatically according to the wire pipe wire pipe Ceiling...
6.5. Installation of pipeline 3kw ~ 13.5kw ① Service hole 1/2’’ ② Steam outlet 3kw~6kw: 1/2’’ 7kw~13.5kw:3/4’’ ③ Safety valve 1/2’’ ④ Water inlet 1/2’’ ⑤ Drain outlet 3/4’’ ⑥ Power supply for drain valve Figure 11 3kw- 13.5kw pipe connection 15kw ~ 24kw ②...
Page 17
i. Water Inlet: First connect the water magnetizer (if applicable) to the water inlet solenoid valve. Then please use a 1/2’’ flexible stainless steel hose to connect the other side of the water magnetizer and the water supply pipeline. Do not connect to metal water supply pipeline directly which may damage the water inlet valve.
vi. Service hole Can be used as maintenance hole or another steam outlet 1/2''.How to do maintenance, please refer to Chapter Warranty And Services. Steam head Steam head Steam generator Stean pipe Aromatherapy Reservoir Flexible stainless steel hose Valve 300 mm Water supply Apply silicone...
6.6.1. Power Supply Single phase, 215-240V,50/60Hz power supply: Connect the live wire to the terminal labeled as “L”; connect the null wire to the terminal labeled as “N” ; and connect the earth wire to the terminal labeled as “ ”.
Page 20
C OM O ve r-he at p ro te ction 2503 term inal blocks AIO 3KW, 4KW European 215 ~240 V single phase Figure 16 _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
Page 21
ca th o d e O v e r-h e a t p rotection 2506 t erm ina l b locks t e rmin a l b lo cks L1 L2 L3 4.5kw 5kw 6kw 7kw 7.5kw European 215 ~240V Single Phase or 380 ~415V 3Phases Figure 17 _________________________________________________________________________________ TOLO SAUNA...
Page 22
4 heating element 5 heating element 6 O ver-he at pro tec tion 2506 term inal blocks L1 L2 L3 AIO 9kw 10.5kw 12kw 13.5kw European 380 ~ 415V 3 Phases Figure 18 _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
Page 23
1 heating element 2 heating element 3 heating element 4 heating element 5 heating element 6 Over-heat protection 4506 terminal blocks AIO 15kw European 380 ~ 415V 3 Phases Figure 19 _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
Page 24
6 heating element 7 heating element 8 heating element 9 Over-heat protection Over-heat protection 4506 terminal blocks L1 L2 L3 Figure 20 AIO 16.5kw 18kw 22.5kw 24kw European 380 ~ 415V 3 Phases _________________________________________________________________________________ TOLO SAUNA info@tolosauna.com www.tolosauna.com...
7. Functions And Operation 7.1. Controller display items AROMA PUMP COLOURED LIGHTS ON/OFF SALT SPRAY Figure 21 AIO Controller Each first touch is for waking up the touch panel. Selection key: AROMA PUMP Function key: COLOURED LIGHTS SALT SPRAY ON/OFF Working time range:1~60 minutes or continuous (CH).
Page 26
Figure 22 Controller display Exhaust fan Salt spray Descaling Colored lights Aroma pump Water inlet valve Change colors Temperature High water level S2-1 automatically instructions Middle water level S2-2 Lock the color Humidity instructions Low water level Working time Water tank temperature Heating instructions Celsius degree...
Page 27
WiFi kit under the same wireless local area network (WLAN). Open the App in your iPhone or Android phone, then you can operate the steam generator by your Phone now. More information, please browse “Steamtec Sauna” App operation guide. After your Phone connect well to steam generator, the all-in-one controller screen will show “App”.
Page 28
room, press the “fast steam” controller, the steam will come out in 30 seconds, runs 30 minutes, it back to stand by (Heat preservation state). S6 lights: steam generator is under commercial model. (Change to domestic model, please cut off the general power supply, then switch the button inside the central function box). domestic model and commercial model change-over...
Page 29
If steam generator is with humidity sensor, the steam generator will stop when the humidity reach the setting value. (Notice: the humidity sensor is not in standard equip. Without humidity sensor, steam generator works depends on the temperature sensor. If steam generator works with humidity sensor, it will stop when the humidity reach the setting value.
S15 Water inlet valve: S15 lights: shows steam generator is inflow S16 High water level: S16 lights: shows the water level in water tank reach to high level. S17 Middle water level: S17 lights: shows the water level in water tank reach to middle level. S18 Low water level: S18 lights: shows the water level in water tank reach to low level.
iv. Auto drainage: If the Descaling time is set as “0”, and after the steam generator is off, system will drain automatically and displays ‘ ” on the screen. The drainage valve will be turned on to drain. If the Descaling time is NOT set as “0”, please ref to “S14 Descaling”. 8.
9. Troubleshooting Repair can only be performed by qualified professionals, for more services or technical helps please contact the dealer. AIO steam generator has self-diagnose function, and some common faults will be displayed on the screen if occur. Code Meaning...
Page 33
Diagnosing procedure: i. The AIO controller can show the status of the steam generator working. ii. If the generator can fill in and drain out water properly but does not heat up, please check the connection wire between main circuit board and the sub-board, the relays on sub-board, and heating elements.
10. Warranty And Services Table 6 AIO warranty time Notes: (1) Warranty period will count from the ex-factory date of the steam generator. (2) Limited free warranty only including provide free spare parts and our remote services, not including any other direct or indirect costs / losses.
(12)Please contact our company for further information and more details. (13)Tips for maintenance: if you buy the AIO auto descaling device, please follow its guideline, if not, please follow below manually descaling methods: How to descale Tolo Sauna Steam Generator? There is a service hole on top of steam generator,you can put descaling liquid through service hole, and let it stay in water tank for 4-8 hours ,then flush.
Need help?
Do you have a question about the AIO and is the answer not in the manual?
Questions and answers
should there be a link between l1, l2 and l3 for single phase as with N
@Raz or should just the single L wire be connected to EITHER l1, l2 OR l3
No, for single-phase Steamtec AIO (3KW, 4KW, 215~240V), the connection should be made to the designated terminals for single-phase wiring. L1, L2, and L3 are used for three-phase connections, so they should not be interconnected for a single-phase setup. Instead, follow the wiring diagram for single-phase installation.
This answer is automatically generated