Head Assembly - Pentair 40E100 RO User Manual

Pressure vessels

Advertisement

F/C Port
Permeate Port
Circlip
Locking Segment
O-rings
Sealing Plate
1. Use only head components in as-new condition. Use
new O-rings each time the head is assembled.
2. Cover O-rings with a this even layer of Parker Super
TM
O-Lube
silicon lubricant or the lubricant recomm-
ended by your element supplier.
Lubricating Plug seals and O-rings
Distributed by Applied Membranes, Inc. | www.appliedmembranes.com | (760) 727-3711 | USA
Head Disassembly (Contd...)
Head Component Identification (40E100) - Head Disassembled

Head Assembly

NOTE
Glycerine is a commercially available
lubricant that will not foul elements.
However, silicon lubricant is
recommended for this application.
3. Assemble one Port Seal into the groove in the Sealing
Plate and the other into the groove on the small end
of the Permeate Port. Insert Adapter seal into the
groove at the large end of the Permeate Port.
Inserting Permeate Port seal
Retaining Ring
Removal Tool
Bearing Plate
Retaining Ring