Download Print this page

Pentair 40E100 RO User Manual page 10

Pressure vessels

Advertisement

Refurbishing Shell
1. Using a fine wire brush, remove any large deposits from
Retaining Ring groove in the vessel.
2. Using a medium or finer grade of ScotchBrite
soap solution, clean the inside of the vessel at least 4
inches in from each end.
3. Use clean water to rinse away all loosened deposits
and soap residue.
4. Examine inside of the vessel for scratches, gouges or
other imperfections that could prevent proper
sealing. If such areas exist and leaks are observed
when the vessel is placed back in service, the shell
may need to be replaced.
Refurbishing Other Parts
1. Remove any large deposits from metal parts using
a wire brush.
2. Scrub the entire surface with medium grade Scotch-
TM
Brite
until all contaminants are removed.
3. Rinse parts clean with fresh water and dry.
4. Inspect all parts for serviceability as specified above.
Remaking Pipe Connections to End
Plug
1. Use a wire brush to remove all foreign matter from
threads on pipe fittings.
2. Scrub the entire surface with medium grade Scotch-
TM
Brite
until all contaminants are removed.
3. Rinse parts clean with fresh water and dry.
4. Inspect all parts for serviceability as specified above.
NOTE
If the head has to be reoriented to attain
suitable port positions, head will have to
be removed and reinstalled as described in
Head Assembly section.
Part Replacement
Replace all parts that cannot be restored to as-new condition.
Replace any parts showing signs of structural damage or
corrosion
CAUTION
Use of components that are damaged by
corrosion can result in catastrophic
failure.
Distributed by Applied Membranes, Inc. | www.appliedmembranes.com | (760) 727-3711 | USA
Refurbishing Parts (Contd...)
TM
and mild
Seals should be replaced necessarily, each time the
vessels are serviced. Any parts that need to be
replaced are available from your supplier or from
Pentair Water.