Pavilion UT199DV Owner's Manual

Pavilion UT199DV Owner's Manual

Condensing tankless gas water heater
Hide thumbs Also See for UT199DV:

Advertisement

Quick Links

CONDENSING TANKLESS GAS WATER HEATER
Model : UT199DV
FOR USE IN RESIDENTIAL OR
MANUFACTURED HOME APPLICATIONS.
WARNING
• Do not store or use
gasoline or other
flammable vapors and
liquids in the vicinity
of this or any other
appliance.
PB HEAT, LLC
Owner's Guide
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
• WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any
phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call the fire
department.
(GQ-C3260WX-FF PB US)
Thank you for purchasing this Pavilion Tankless Gas Water
Heater.
Before using:
• Read this manual completely for operation instructions.
• To be covered by the Pavilion Limited Warranty service, see
the warranty registration information (See page 23), and
then visit the Pavilion web site (https://www.peerlessboilers.
com/).
• Keep this manual because the warranty registration
information is included (See page 23).
Installation must conform with local codes, or in the absence of
local codes, the National Fuel Gas Code, ANSI Z223.1 / NFPA 54
- latest edition and/or the Natural Gas and Propane Installation
Code CSA B149.1 - latest edition.
When applicable, installation must conform with the
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280 or the Canadian Standard CAN/CSA-Z240 MH
Mobile Homes, Series M86.
PB Heat reserves the right to discontinue, or change at any
time, the designs and/or specifications of its products without
notice.
SBB819D-1
Rev. 12/19
• Installation and service
must be performed by
a qualified installer,
service agency or the
gas supplier.
Low NOx Approved by SCAQMD
14 ng/J or 20 ppm
(Natural Gas Only)

Advertisement

Table of Contents
loading

Summary of Contents for Pavilion UT199DV

  • Page 1 Thank you for purchasing this Pavilion Tankless Gas Water Heater. Before using: • Read this manual completely for operation instructions. • To be covered by the Pavilion Limited Warranty service, see the warranty registration information (See page 23), and then visit the Pavilion web site (https://www.peerlessboilers. com/).
  • Page 2: Important Safety Information

    Important Safety Information To prevent damage to property and injury to the user, the icons shown below will be used to warn of varying levels of danger. Every indication is critical to the safe operation of the Water Heater and must be understood and observed. Potential dangers from accidents during installation and use are divided into the following four categories.
  • Page 3 WARNING To prevent burns or scalding, turn off the button and wait until the appliance cools A. This Water Heater does not have a pilot. before performing maintenance. It is equipped with an ignition device that automatically lights the burner. Do not try Do not place the exhaust vent terminal in an to light the burner by hand.
  • Page 4 WARNING [When supplying combustion air from the indoors] Be sure the gas/power supplied matches Check the air supply opening for dust or “Type of Gas” and “Electrical Rating” on the obstructions. rating plate. To prevent injury or death, do not allow small children to bathe or play in the bathroom unsupervised.
  • Page 5 This may cause damage or failure. If the water supply is in excess of 12 gpg Contact Pavilion Customer Center before using (200 mg/L) of hardness, acidic or otherwise with a solar pre-heater.
  • Page 6: Table Of Contents

    Contents Important Safety Information ....2 Contents ..........6 General Parts ........7 Water Heater ........7 Remote Controller ........ 8 Initial Operation ........9 Using the Water Heater ......10 Setting Hot Water Temperature ....11 Customizable Settings......12 Limiting the Maximum Output Temperature ..........
  • Page 7: General Parts

    General Parts Water Heater Indoor Installation Outdoor Installation Outdoor Vent Cap Flex Vent 2 in. Conversion Kit 1. Intake Pipe 2. Exhaust Pipe 3. Pressure Relief Valve 4. Hot Water Valve 5. Water Supply Valve 6. Water Drain Valve (with Water Filter) Inside Water Inlet (See page 17) 7.
  • Page 8: Remote Controller

    Remote Controller • What is actually displayed depends on how the Water Heater is set. • Before use, remove the protective sheet from the Remote Controller surface. 1. POWER Button / Indicator 5. BURNER ON Indicator For turning the Water Heater ON/OFF. When burning, the indicator is displayed.
  • Page 9: Initial Operation

    Initial Operation Before the first use, do the following: 1. Open the water supply valve. CLOSED OPEN 2. Open a hot water fixture/faucet to confirm that water is available, and then close the fixture/faucet again. Hot water fixture/faucet 3. Open the gas supply valve. 4.
  • Page 10: Using The Water Heater

    Using the Water Heater Operation 1. The button is ON. PRIORITY indicator is displayed. (e.g. 110°F) • The POWER indicator is displayed. • The previously set hot water supply temperature is shown. • The setting temperature displayed may vary from the actual temperature at the fixture depending on conditions such as season or length of piping.
  • Page 11: Setting Hot Water Temperature

    Setting Hot Water Temperature Temperature Setting Options Operation The temperature settings below are examples. 1. The button is ON. The temperature setting necessary depends on the usage, the length of piping and the season. PRIORITY indicator is displayed. [When using °F mode] (Default setting is 110°F) Washing dishes, etc.
  • Page 12: Customizable Settings

    Customizable Settings Limiting the Maximum Output Muting the Remote Controller Flow Meter Alarm Temperature The Remote Controller will The flow meter alarm is being The maximum output emit a sound when any button used to indicate when a tub is full. temperature can be limited to is pressed.
  • Page 13: Preventing Damage From Freezing

    Preventing Damage from Freezing Take the measures below for extremely NOTICE cold temperatures*. • Damage can occur from frozen water within * Outside temperature including wind chill factor less the appliance and pipes even in warm than -30°F (-35°C) when supplying combustion air environments.
  • Page 14 9. Close the gas valve and disconnect If the Water Heater will not be used for a the electrical power supplied to long period of time, drain the water. the Water Heater. Do not touch with wet hands. WARNING Manual Draining •...
  • Page 15 Turning the Water Heater Back On DANGER After the Water Heater has been out of use for a long time, make sure that you fill the condensate trap with water. This is to prevent dangerous exhaust gases from entering the building. Failure to fill the condensate trap could result in severe personal injury or death.
  • Page 16: Regular Maintenance

    Regular Maintenance Periodic Inspection Check : B For dust and soot in the exhaust vent or the exhaust vent terminal. Periodic check and maintenance should be Check : C performed once a year by a qualified service • For abnormal sounds during operation. technician to assure that all the equipment is •...
  • Page 17 Customer Center for more information. (https:// www.peerlessboilers.com/ or 1-855-443-8468) • Damage to the Water Heater as a result of below is not covered by the Pavilion Limited 2. With a bucket ready, remove the water drain Warranty. To ensure full warranty coverage, treat valve.
  • Page 18: Troubleshooting

    Troubleshooting Initial Operation The hot water is not the correct temperature. • Is the hot water fixture/faucet sufficiently open? The Water Heater does not attempt to ignite when water is running. Water takes time to become hot when turning • Check for reversed plumbing or crossed pipes. the hot water fixture/faucet.
  • Page 19 Amount of Hot Water Other The amount of hot water at a certain fixture is The Water Heater stops burning during operation. not constant. • Are the gas and water supply valves fully open? • When hot water is demanded at other fixtures, •...
  • Page 20: Follow-Up Service

    First follow the instructions in the troubleshooting number doesn’t return the problem is section. (See page 18-20) solved. If the error is not corrected, contact Pavilion Customer Center at https://www.peerlessboilers. Error Code : 90 com/ or 1-855-443-8468. Cause : [When supplying combustion air from the...
  • Page 21 These items will replace the conversion kit directly from the manufacturer. existing parts that are currently installed in the • For more information, contact Pavilion Customer Water Heater. Center at 1-855-443-8468. Venturi Mixer Conversion O-Ring (×...
  • Page 22: Specifications

    • Specifications may be changed without prior notice. • The capacity may differ slightly, depending on the water pressure, water supply, piping conditions, and water temperature. Item Specification Model Name UT199DV (GQ-C3260WX-FF PB US) Installation Indoor / Outdoor Wall mounted Type Air Supply / Exhaust Power Vented...
  • Page 23: Warranty

    PB Heat, LLC, Bally, Pennsylvania, hereinafter referred to as 1. Component parts not manufactured by PB Heat as part of “PB Heat”, warrants to the original owner of any Pavilion™ the Product or damage to surrounding areas or property condensing tankless gas water heater, hereinafter referred caused by leakage or malfunction.
  • Page 24 Warranty THE PAVILION™CONDENSING TANKLESS GAS WATER HEATER ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES 2. The Product should be provided with combustion air free OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR of contaminants such as, but not limited to, chlorine, PURPOSE, ARE HEREBY DISCLAIMED WITH RESPECT ammonia, excessive dust, dirt, construction particles, TO ALL OWNERS.

This manual is also suitable for:

Gq-c3260wx-ff pb usUt series

Table of Contents