230 V Mono-phase control unit for rolling shutters, awnings, barriers.
Time acquisition "real-time", radio receiver included (HCS rolling code),
"Man present" function with remote control. Intervention of photocell when closing, Stop. Courtesy Light
230V AC Control Board
Manuals and warnings
14
10
11
12 13
15
16
17 18 19 20 21
P1
ON
ON
LED L1
Functioning
1 2 3 4
1 2 3 4
1 2 3 4
D
P I
A
D
P I
B
DIP C
FUSE 4A
Power Switch
1
2
3
4
5 6 7
8 9
2002/95/EC

Advertisement

loading
Need help?

Need help?

Do you have a question about the START-S2XL and is the answer not in the manual?

Questions and answers

Summary of Contents for SAMT START-S2XL

  • Page 1 230 V Mono-phase control unit for rolling shutters, awnings, barriers. Time acquisition “real-time”, radio receiver included (HCS rolling code), “Man present” function with remote control. Intervention of photocell when closing, Stop. Courtesy Light 230V AC Control Board Manuals and warnings 12 13 17 18 19 20 21 LED L1...
  • Page 2 Foreword This manual provides all the specific information you need to familiarize yourself with and correctly operate your unit. Read it very carefully when you purchase the instrument and consult it whenever you have doubts regarding use and before 230 Vac NEUTRAL performing any maintenance operations.
  • Page 3 1.00 Installation: Scheme of the control unit I LED When the control unit is powered, the LED, which are in the inputs, are turned on when the input common contact is closed: 12 13 17 18 19 20 21 Red LED ( normally closed ) turned on: Opening Limit Switch close LED red ( normally closed ) turned on: STOP contact closed LED red ( normally closed ) turned on: STOP contact closed LED red ( normally closed) turned on = FOTO contact closed...
  • Page 4 1.01 Type of electrical wires Depending on the installation, the type and number of devices installed, the number of cables needed can vary. The table below shows the cables needed for a typical installation. The cables used in the installation must be IEC 60335 compliant. Power supply line Cable 3x1,5 mm Motor cable (if not equipped)
  • Page 5 Description of the KIT version 230V AC Control Board The kit version includes Box for Control Unit 115mm x 165mm x 65mm Control Card 2 Channel receiver (START/OPEN and CLOSE)
  • Page 6 2.00 Connection of the motor Pay attention not to invert the poles OPEN and CLOSE. In case of doubts, put the gate manually in the middle. Be ready to stop the gate with a STOP control. Make sure that the control OPEN is really OPEN, try to interrupt the photo-beams:if the gate starts closing, the connection is not correct and you need to reverse the cables OPEN and CLOSE of the motor CLOSE...
  • Page 7 2.04 Connection of the control OPENING AND CLOSING The connection of the opening control START (16-19) or closing (17-19) can be done with any button or with a normally open contact. In case of more devices, they should be serial connected. If you use the terminal board START (16-19) it is possible to connect a TIMER to program the opening of the gate.
  • Page 8 3.00 Remote control: cancellation of the memory The control unit dispose of a button PULSANTE P1 for different operation, one is the cancellation of all codes inside the memory. To cancel make the following two steps. The output of the control boards are not activated , eventually lights connections should be turned off. This operation is possible only when the gate is closed.
  • Page 9 3.02 Remote controls: memorization of the codes The control unit dispose of a button PULSANTE P1 to program the worling time and to memorize the code of the remote controls. If you use a new FIXED CODE remote control like SMILE-C, make sure that all butoons have a code otherwise you need to create a code.
  • Page 10 4.00 Program of the DIPA to exclude the connections The control unit dispose of micro-switches DIPA and DIP B and DIPC which can activate or deactivate different functions to give more safety. Dip 1 It excludes the connection of the Opening Limit Switch . And vice versa Dip 2 It excludes the connection of the Closing Limit Switch.
  • Page 11 5.00 Turning on and learning of the control unit If everything has been correctly connected, when turning on the red light of LED L1 TEST should flash, while STOP, FOTO, FCA( opening Limit Switch), FCC (Closing Limit Switch) should lit up (if the gate is closed and if the closing limit switch is connected, it should turned off) .
  • Page 12 Adress: Corso Sempione 172/5 The undersigned Ernestino Bandera, 21052 Busto Arsizio VA Italia Administrator Product’s name: START-S2XL 230 Vac mono-phase DECLARES THAT: control unit THE PRODUCT COMPLIES with what is outlined in the European Community directive: EC DIRECTIVE 98/37 ISSUED BY THE EUROPEAN PARLIAMENT AND...