General Description

Scope of Delivery

-
Domestic water system
-
Instruction Manual
The diagram of the most impor-
tant functional elements can be
found on the foldout side.

Overview

A
1
Water outlet
2
Filler screw
3
Carrying handle
4
Pump
5
Pressure vessel
6
Drillhole for fixed installation
7
Power cable
8
Draining screw
9
Pressure gauge
10
Automatic switch
11
Pressure hose
12
Water inlet
13
On/Off switch
14
Protective cap for air valve

Functional description

The domestic water system automatically
transports water. The pump switches on
depending on the pressure and transports
water. The switch-on point is set in the
works and cannot be adjusted.
Please refer to the descriptions below for
information about the operating devices.

Technical Data

Domestic
water system ..........HWW 3819 InoxInox
Mains connection.............. 230 V~, 50 Hz
Power consumption ................. 1000 Watt
22
Tank volume ...................................... 19 l
Suction lift .......................................... 7 m
Max. discharge rate .................... 3800 l/h
Max. discharge head ....................... 44 m
Max. discharge head with pressure
vessel .............................................. 30 m
Max. water temperature.................. 35 °C
Hose connection ................................... 1"
Turn-on pressure ....... 0.15 MPa (1,5 bar)
Turn-off pressure ....... 0.30 MPa (3,0 bar)
Safety class ............................................ I
Degree of protection ........................ IPX4
Noise pressure
level (L
) .. 75.22 dB (A); K
pA
Noise performance level (L
measured ..88.24 dB (A ); K
guaranteed ............................ 91 dB (A)
Technical and optical changes can be car-
ried out in the course of further development
without notice. All dimensions, references
and information of this instruction manual
are without guarantee. Legal claims, which
are made on the basis of the instruction
manual, cannot thus be considered as valid.

Notes on Safety

This section deals with the general
safety regulations for working with
the equipment.
= 2.89 dB
pA
)
WA
= 2.89 dB
WA