Inspection, Testing, And Maintenance; Document References - Eaton Magnum DS Instructions Manual

Metal-enclosed low-voltage nema 3r assemblies
Hide thumbs Also See for Magnum DS:

Advertisement

Instruction Booklet IB01900002E
Effective June 2011
Section 5: Inspection, Testing and
Maintenance
For complete instructions regarding inspection and testing of
Magnum DS switchgear and switchboards prior to start-up and oper-
ation, see Section 5 of IB01901001E. Read and follow all instructions
regarding safety practices described therein.
DANGER
ENERGIZING THE SWITCHGEAR FOR THE FIRST TIME IS POTENTIALLY
DANGEROUS. THEREFORE, ONLY QUALIFIED PERSONNEL SHOULD BE
PRESENT WHEN THE EQUIPMENT IS ENERGIZED. IF PROBLEMS CAUSED
BY DAMAGE OR POOR INSTALLATION PRACTICES HAVE NOT BEEN
DETECTED IN THE CHECKOUT PROCEDURE (PREVIOUSLY DESCRIBED),
DEATH, PERSONAL INJURY OR SERIOUS DAMAGE MAY RESULT WHEN
POWER IS APPLIED.
For instructions regarding periodic maintenance of switchgear/
switchboard devices, bus and connections, as well as replacement
parts, see Section 6 of IB01901001E. Read and follow all instructions
regarding safety practices described therein.
DANGER
WHEN ENERGIZED, A CIRCUIT BREAKER IS PART OF A HIGH POWER
SYSTEM. BEFORE ATTEMPTING ANY INSPECTION OR MAINTENANCE,
BE SURE THAT ALL PRIMARY AND CONTROL CIRCUITS HAVE BEEN
DE-ENERGIZED AND GROUNDED AS REQUIRED. ALSO MAKE CERTAIN
THAT PROPER STEPS HAVE BEEN TAKEN TO BE SURE THAT THEY WILL
REMAIN DE-ENERGIZED UNTIL ALL WORK IS COMPLETED. FAILURE TO DO
SO MAY RESULT IN DEATH, BODILY INJURY OR ELECTRICAL SHOCK.
14
EATON CORPORATION www.eaton.com
Instructions for Magnum DS Metal-Enclosed
Low-Voltage NEMA 3R Assemblies
Section 6: Document References
In addition to this Instruction Book, the following Instruction Books
and drawings are commonly included in any low-voltage assembly
shipment. Please inspect the packet attached to the outside, or
within an empty cell, for all pertinent documentation before contact-
ing an Eaton service representative for replacements.
Magnum DS Structure Section View Type DS
2A97855
Low-Voltage Metal-Enclosed Switchgear
4A37896
Magnum DS Structure Base Plan
Shipping Split Bus Information
9253C18
Installation Space Requirements
9253C21
In addition, the following documents may be included depending
upon optional equipment contained within the assembly:
4A37898
Installation Guidelines for Users of Magnum DS
Low-Voltage Rear/Front Access Switchgear
Assemblies for Seismic Applications
Instructions for Installation, Operation and
IB 2C12060H08
Maintenance of Magnum DS, DSX and DSL Low
Voltage Power Circuit Breakers
IB 2C12063H02 Instructions for Installation, Operation and
Maintenance of Magnum SB Insulated Case Low
Voltage Power Circuit Breakers
Instructions for Field Testing of Ground Fault
IB 32-693A
Systems Utilizing Eaton Magnum DS Circuit
Breakers
IB 32-698C
Instructions for C-HRG "Safe-Ground" Low-
Voltage High Resistance Pulsing Ground System
IB 52-01-TE
Instructions for Eaton Type CM52 Network
Protectors 800 to 4500 Amperes
Instructions for Installation, Operation and
MN01301001E
Maintenance of Series NRX Low Voltage Power
(Air) Circuit Breakers
Also, supporting documentation and instructions for auxiliary compo-
nents and devices contained within the assembly will be forwarded
with any shipment. The accuracy of claims made within documents
by other manufacturers is not the responsibility of Eaton but the
device manufacturer.
There are numerous supporting documents which are not listed
here due to the wide variety of components contained within any
given assembly. For a full selection of available documents, see the
Technical Documents section of www.Eaton.com.