4 relay external mini receiver

Advertisement

4.2 - Fixing
Remove the receiver cover.
Fix the box by using the screws and the plugs supplied
Fig. 3
At the end place the taps supplied over the holes to
protect the screws head.
5 - LAYOUT E CONNECTIONS
K1
K2
K3
K4
DL1 DL2
DL3
1 2 3 4 5 6 7 8 9 10 11 12 13
ch1
ch2
ch3
46
80
JP1
P1
DL4
0 12 24
ch4
ac / dc
5.1 - Contacts
terminal 1 =
terminal 2 =
terminal 3 =
terminal 4 =
terminal 5 =
terminal 6 =
terminal 7 =
terminal 8 =
terminal 9 =
80
terminal 10 =
terminal 11 =
terminal 12 =
terminal 13 =
terminal 14 =
terminal 15 =
5.2 - Relay K4 Configuration
The relay K4 can be configured in step mode. Close the
jumper JP1.
JP1 = CLOSED
K4 Step mode
14 15
6 - TX PROGRAMMING
Memorizing
The receiver makes the memorization of the transmitters
buttons in sequential way.
Keep the button P1 pressed down until the red led DL3
switches on , release P1 and push the key "A" of the
transmitter ; after push again P1, the second red led DL4
switches on , release P1 and push the key "B" of the
transmitter. After a while both the led will switch off and the
procedure will be finished.
Contact NO Relay1
Contact C Relay1
Contact NO Relay2
Contact C Relay2
Contact NC Relay2
Contact NO Relay3
Contact C Relay3
Contact NO Relay4
Contact C Relay4
Contact NC Relay4
Input supply Common
Input supply +12 Vac/dc
Input supply +24 Vac/dc
Pole Antenna
GND Antenna
JP1=OPEN
K4 Pulse mode