Note This document is just for information about how to use the mobile combi device HFU 4500D from Leuze electronic. All important details about the functionality and the handling were described further on. In addition the typical connections together with the modular connector units (MA) are in this manual, too.
Attention! Access to or changes on the device, except where expressly described in this document, are not authorized. Qualified personnel Mounting, commissioning and maintenance of the device must only be carried out by qualified personnel. Electrical work must only be carried out by a certified electrician. Short description HFU 4500D Leuze electronic Page...
5. With the black marked keys the function is selected and with the yellow marked key activated. Settings for data output, code types etc. can be set in the ‚system‘ area (right yellow key). Short description HFU 4500D Leuze electronic...
The read characteristics are printed on page 8 Test barcode The printed code is to test the functionality of the scanner, module(bar) width is 0.5 mm (20 mil) Code 39 Bar Code Sample Short description HFU 4500D Leuze electronic Page...
Valid Standards EN 301489-3 EN 302208-1 Protection class IP54 Temperature (operation) -20 to 50 °C (storage) -20 to 50° C * depends on used Transponder **depends on used optical 1D / 2D code type Short description HFU 4500D Leuze electronic Page...
ECC200, PDF, QR, Maxicode, GS1-codabar Familiy Cell size: 0.21 to 0.9mm, Working area RFID Antenna TFU05 TFU10 450mm Readable Transponder-Types: EPC1Gen2 (NXP G2XM, GSXL, Alien Higgs3 Out of ISO18000-6C) Using the HFU 4500D Short description HFU 4500D Leuze electronic Page...
In any case the device comes back with a message (success/ failure) onto Display / Interface. The sequence is fixed, an interrupt is only possible with C. All parameter settings can be found in the sub menus inside the system area/barcode and RFID (see menu structure). Short description HFU 4500D Leuze electronic...
Page 10
(activate Messages) with “SFC0” when no function is selected, “SFC1” with selected function 1 (SCAN Barcode) etc. (see no 3.) Note: Please combine Commands and Data (characters or numbers) directly (without space between) into One single telegram, enclosed of the telegram prefix/suffix Short description HFU 4500D Leuze electronic Page...
Note: All individual settings are lost then!!! Parameter Setting All parameters are available and can be set via key board in different sub menus within the system menu. No separate or special software tool is needed. Short description HFU 4500D Leuze electronic Page...
Telegram- / Command structure The factory presets are similar to the other available fix mounted RFID- devices from Leuze electronic. The Standard telegram structure is shown below, with 9600Bd, 8 Databits , N,1 : Command CR LF ASCII-Character 0Dh 0Ah For this device you can change the telegram frame and the Baudrate.
Type in Start block no. and No of Blocks, factory 05 RFID Write Data output PREfix Type in Telegram-Start character, factory STX SUFfix Type in Telegram-End character , factory 0D,0A Select ASCII / HEX, ab Werk ASCII Data format Short description HFU 4500D Leuze electronic Page...
Page 14
ON/OFF for Send Messages via Interface, factory OFF ON/OFF for Send NORead Message, factory OFF NO Read ON/OFF for Inputline to type in Quantity, factory OFF USE Qty Qty separator Choose separator sign for Quantity in output telegram Short description HFU 4500D Leuze electronic Page...
Page 15
* Note: The availability of the memory banks TID (serial number), EPC and User block depends on the used transponder chip and may be not always available. The EPC bank is typically available with 8 – 12 characters and 4-6 blocks at any chip type. Short description HFU 4500D Leuze electronic...
HFU 4500D at serial PC-Interface With power supply via PIN 9 via RS232-cable neccessary parts: 50113280 HFU 4500D, incl. cable 4m length Pinning of the 9 Pol- D-Sub (female) PIN-No Signal Description Transmit Data (-5 to +5V) Recieve Data (-5 tos +5V)
HFU 4500D with USB (COM-Port-Emulation) To use the HFU45xxD with USB you use the standard RS232 cable and connect the USB Converter cable. The data is sent to the new COM-Port. The necessary driver is available on www.leuze.de. the interface is set to 9600,8,N,1.Separate power supply needed.
7. RFID: Please check the settings for RFID and check the transponder type with your supplier. If the settings are correct the transponder can be defect as well- try another one if possible. 8. Now you checked most possibilities. For further support please contact the Leuze Service. Short description HFU 4500D Leuze electronic...